有故障的電路 的英文怎麼說

中文拼音 [yǒuzhàngdediàn]
有故障的電路 英文
faulted circuit
  • : 有副詞[書面語] (表示整數之外再加零數): 30 有 5 thirty-five; 10 有 5年 fifteen years
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • : 4次方是 The fourth power of 2 is direction
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  • 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
  1. The two - point to earth short fault may cause short currents whic h can lead to serious accident. so it is necessary to monitor the state of field windings of turbo - generator and detect the kind of fault and predict its inclination. thus the security level of power system will be improved

    由於發機轉子兩點接地時會產生較大流,導致惡性事發生,因此對發機轉子繞組進行狀態監測,判斷短形式和趨勢是十分必要,助於提高系統安全運行水平。
  2. The 4 - layer printed circuit board, which proposes good electro magnetic compatibility, electrical trait and heat elimination ;. full / half duplex auto - negotiation support ; diagnostic monitoring for malfunction indication and troubleshooting ;. supporting hot - pluggable ; good compatibility ; good at heat elimination. 1. 25gbit / s sfp optic transceiver has been deployed in various broadband applications will be used in backbone networks of ring or daisy - chain topologies

    我們設計光纖收發器良好磁兼容性,並保證了特性和散熱特性、支持全半雙工自適應、具數據診斷功能、準確方便判斷網、支持熱插拔操作、兼容性良好。
  3. Slave computer knows master computer with some trouble when the communication assumption between master computer and slave computer has changed. then control circuit will be automatically switched to slave computer, slave computer will take place of the task of master computer and inform some related person to deal with the trouble in order to resume the normal work. man - machine conversation windows of the control system adopted visual basic 6. 0 to design

    上、下位機之間通訊採用串列通訊方式,上位機正常情況下負責實時運行,當上位機遇到時,上、下位機之間通訊約定會發生變化,這樣下位機就會知道上位機,控制運行切換到下位機系統運行,下位機通過撥號系統通知關人員,及時處理,以使上位機盡快恢復運行。
  4. The precise location of high - voltage transmission line fault is of great significance and practical engineering value

    高壓輸準確定位具非常重要意義和工程實用價值。
  5. To find the failure propagation mechanism from the inherent topological structure of the complex electromechanical system, the topological structure statistical properties of the system were analyzed with small world net theory, and a failure propagation model based on the small world clustering was proposed

    摘要為了從復雜機系統自身固拓撲結構出發來研究傳播機制,採用小世界網理論分析方法,對系統網拓撲結構統計特性進行分析,建立了基於小世界聚類特性傳播模型。
  6. During the repair time of elements of the distribution networks, because there are some open connecting switches, service restoration reconfiguration can be carried out in order to restore outage areas service

    網發生時,由於配網中一些常開聯絡開關,所以可以進行恢復網重構,盡可能使非區恢復供
  7. In the paper, based on the existing literature research foundation an analog circuit catastrophic fault location approach by using feedforward networks with back ? propagation learning is realized. by this approach, the simulation require ments before test are reduced because fewer training samples are needed, and the fault location process is fast. this method is very efficient in location of single hard fault wit component tolerances. the measureme nt space feature and the general characterization concept of single and double soft fault in linear circuits are presented. according to this concept, a linear circuits soft fault location approach using subhidden layer bpnn is established with element tolerance, and it is shown that this approach is successful in fault location. a double fault feature extraction.,

    本文在現文獻理論研究基礎上實現了採用bp演算法前向多層神經網對直流測試下模擬診斷方法。其特點是採用少量典型特徵樣本作為bp網訓練樣本,獲得訓練樣本代價小,減少了測前工作量,同時診斷速度快,在考慮元件容差時仍診斷效果。文中介紹了線性單一軟和雙軟所具壓增量空間特性和統一特徵概念。
  8. The fault diagnosis of the analog circuits is an advanced synthesis intercrossed subj ect, which is an application technology absorbing the new theory, technology and method in other subjects and fields. in the past 40 years, it has developed a great deal of theory and approaches. but the approaches are limited to deal with fault diagnosis because of the variety and complexity of the analog circuits, especially the large - scale analog circuits with the tolerance or the soft fault. artificial neural networks ( ann ) which have been one of the most active research areas recently can be contributed to solve problems in various practical fields. in this paper, analog circuit fault diagnosis approach based on pattern recognition, and ann is expatiated

    模擬診斷是一門不斷發展中綜合交叉性學科,是在不斷吸收其它學科和領域新理論、新技術和新方法基礎上向前發展一門應用技術。雖然經過了四十多年發展,也已經形成了一系列診斷理論和方法,但由於模擬特別是容差大規模模擬多樣性和復雜性,使得可用於診斷容差模擬和大規模模擬方法還十分限。人工神經網理論近年來取得了快速發展,已開始在各個研究領域廣泛應用。
  9. Moreover, it has function to fault phase identification and fault distance measurement

    另外,該神經網式阻抗繼器還具選相和測距功能。
  10. The false alarm is a fault indicated by bit or other monitoring circuitry where no fault exists

    虛警是機內測試或其它檢測指示而實際上不存在現象。
  11. The fault diagnosis of power electronic circuits is one of the most important task in power system. compared to other circuits, the fault diagnosis of power electronic circuits depends on the out - voltage wave of the circuits

    診斷是力系統研究重要課題之一,它與一般診斷不同,以輸出波形來診斷是否及屬於何種
  12. However, in current design flow, designers do not consider whether designs are friendly to opc before they are sent to foundries. in fact, a lot of features in such designs can not be corrected enough because of many factors such as the constraints of environments. so even though such designs are corrected, many lithographic errors still exist

    然而,由於在當前集成設計流中,在設計出版圖送到製造廠商前,設計者並沒考慮版圖對光學鄰近校正和交替移相掩模友好性問題,這使得版圖中一些圖形由於周圍條件限制,如無法充分進行光學鄰近校正,無法進行交替移相掩模處理等,從而使得版圖設計即使進行了校正處理,還存在大量光刻可能性。
  13. Utilities spends significant amounts of money on insulator washing and cleaning before the restoration of the service. laboratory studies and industrial experience have shown that both contamination and wetting of insulator surfaces, which initiate the flow of leakage current, are required for insulator flashover. the leakage current leading to flashover has distinctive stages of development

    人們在詳盡理論分析和大量高壓實驗后,發現絕緣子泄漏變化與其污穢及受潮程度著密切關系,綜合反映了污閃發生過程,因此泄漏流檢測是診斷線絕緣子早期一種效手段。
  14. At the same time, these new motor protections can record and analyse the faults. further more, they can be connected by a network, for the purpose of being easily contolled. and, this dirction of development has been the major direction of this relm

    這種新型保護系統與傳統保護系統相比,具強大邏輯分析與處理功能、可兼記錄與分析功能、易於實現網化管理等顯著優點,成為當前機保護裝置主要發展方向。
  15. For the convenience of test, varied circuit chip defects caused by the production process are abstracted as all kinds of models. at present the commonly used fault models mainly consist of stuck - at fault, stuck - open fault, bridge fault, store fault, delay fault, etc. testing methods based on voltage testing mainly aim at stuck - at fault model and have also obtained satisfactory result in research for many years. bridge fault is tested easily by quiescent power supply current ( iddq ) testing method. in regard to stuck - open fault that is difficult to testd by quiescent power supply current ( iddq ) and voltage testing, it can is tested by the dynamic current ( iddt ) testing

    為了便於測試,我們將生產過程中集成出現多種多樣缺陷抽象為各種模型。目前常用模型主要:固定,開,橋接,存儲,時滯等。壓測試主要針對固定型模型,多年研究也取得了令人滿意結果; cmos橋接則宜用穩態流測試方法( iddq )測試;對于壓和穩態流難以測試,可以使用瞬態流測試( iddt )方法進行測試。
  16. The result shows that the soft and hard faults will have different significance to the performance of circuits at a wide range of defect size. the relationship between yield and reliability is concerned for a long time

    最後以一個4x4移位寄存器為例,驗證了該方法效性,最後模擬結果給出了在不同粒徑時,軟、硬性能影響程度比較。
  17. Based on the analysis of the transient and stable features of fault information on line in single carrier power supply with ineffective grounding neutral, this paper puts forward a new method for fault location in small current power system called " gradual identifying law "

    本文針對這一問題,在深入研究了中性點非效接地單端供系統發生單相接地后線各處信息暫態特性和穩態特性基礎上,提出了一種新流接地系統單相接地定位方法- 「遞進信息法」 。
  18. In view of the decline of the reliability of door control in dc01 electrical train, this paper introduces the control system for passenger compartment door and the causes of the failure, and argues that the improvement of the door control delay, the opening circuit and the limit switch is the key to enhance the reliability of door control and to reduce the vehicle fault

    摘要針對上海地鐵dc01型動列車客室車門氣控制系統可靠性下降問題,介紹了車門氣控制系統,分析產生車門根本原因,從門控繼器、開門、車門限位開關等方面對車門氣控制系統進行改造,提高了門控系統氣可靠性,效降低了車門率。
  19. Prosprosing a tansformer winding model to judge whether the transformer has come into bing interturn short circuit and the degree of interturn short circuit, and providing an availability for condition monitoring of transformer that improves the accuracy of condition monitoring and fault diagnosis. 3. the accuracy and invalidity of diagnosis of fault positions and fault characters of power transformer would be improved greately if reasoning and analyzing the operation records and oringnal datums of transformer

    建立變壓器繞組狀態監測和診斷模型,通過對繞組在線監測判斷繞組是否發生了匝簡短、具體哪一相發生匝間短以及匝間短嚴重程度,為變壓器狀態監測提供了狀態監測量,實現了變壓器局部定位,效地提高了力變壓器診斷準確性。
  20. Ist - 100m - s / m consists of a module and a hull. the technological characteristics of the former are : 4 - layer printed circuit board, which proposes good electro magnetic compatibility, electrical trait and heat elimination ; full / half duplex auto - negotiation support ; with status leds for malfunction indication and troubleshooting ; supporting insert & pull when electrified ; good compatibility

    收發器模塊部分技術特點是:採用四層板,良好磁兼容性,並保證了特性和散熱特性;支持全半雙工自適應;設狀態指示燈,準確方便判斷網;支持熱插拔操作;兼容性良好。
分享友人