流量量熱計 的英文怎麼說

中文拼音 [liúliángliáng]
流量量熱計 英文
flow calorimeter
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
  • 流量 : rate of flow; flow; runoff; discharge; throughput; (flow) rate; quantity (of flow); flux
  1. In this paper, using phoenics software to compute and analyze the variety rule of the convecting transfer heat at the basis of computing and analyzing the temperature and velocity field of one underfloor supply air room with a focus hot source, and concluding that the number of the hot source and the supply air outlet > the intensity of the hot source and the volume of supply air will influence convecting transfer heat, and obtained its correlativity formula

    本文針對一下部有集中源的地板送風空調小室,利用phoenics軟體,在算分析小室內氣的速度場及溫度場的基礎上,對對轉移的變化規律做了算分析,最後得出對于下送風小室的對轉移源的個數、送風口個數、源強度、送風等因素有關,並且得出了其相關關系式。
  2. The variations of sea ice in the arctic ocean are simulated by using a improved high resolution hibler dynamic - thermodynamic sea ice model during 1979 - 1998. the model is driven by surface atmospheric and oceanic forcing consists of geostrophic winds, surface air temperature, specific humidity, and longwave and shortwave radiative fluxes provided by international arctic buoy program ( iabp ). the simulated results show that arctic sea ice have noticeable seasonal and annual variability

    利用一個hibler海冰動力模式,在改進了其力部分和改變模擬范圍以及提高解析度的基礎上,以北極國際浮標劃( iabp )提供的1979 - 1998年間逐日變化的日平均海平面氣溫場,濕度場,長短波輻射場,風場,洋場,海洋場為強迫場,模擬了上述20年間北極海冰的時空演變。
  3. Also the theoretical basis of the method have been checked through simple deducing simulation and the influences of various physical parameters on the method have been studied. it is shown that the method is theoretically reliable for the production oil wells without very high production rate and is more suitable in field production for oil wells ( i ) in area with bigger geothermal gradient ; ( ii ) producing fluids ( oil and water ) with distinguish thermal characteristics ; ( iii ) producing oil with lower heat capacity or water with higher heat capacity ; ( iv ) with good surface measurement accuracy, as well as the method h as certain requirements on the accuracy of the temperature and flowmeter logs sensors

    就該產出剖面方法的理論基礎進行了簡單的正演模擬和可能影響該方法的各項物理參數進行了全面的考察,結果表明,該方法對于非高產的生產油井來說在理論上是可靠的,在實際生產中適合於( 1 ) 、油井所在地區地溫梯度較大的油井; ( 2 ) 、油水特性差別較大的油井; ( 3 ) 、油比容值偏低水比容值偏高的油井; ( 4 ) 、井口精度較高的油井,並且對井溫測井和測井的傳感性精度有一定的要求。
  4. The theoretical calculation and the experimental result indicated that, after temperature compensation, this kind of new hotwire air mass flowmeter still had high measuring accuracy when the environment temperature had wide range change

    理論算和試驗的結果表明,經環境溫度補償后,這種新型線式空氣質在大范圍環境溫度變化下仍具有較高的測精度。
  5. Contraposing the measurement principle of the traditional hotwire air mass flowmeter, the reason of the excursion of the result for flow measurement was analyzed and inferred when environment temperature changed ; the method for temperature compensation and the realization circuit was given ; and compared the theory output of the new type hotwire air mass flowmeter with its real output after temperature compensation

    摘要針對傳統型線式空氣質的測原理,分析和推導出當環境溫度變化時對結果產生偏移的原因;提出了一種環境溫度的補償方法和具體的實現電路;並對經環境溫度補償后的一種新型線式空氣質的理論輸出和實際輸出進行了算與比較。
  6. Standard test method for melt flow rates of thermoplastics by extrusion plastometer

    使用擠壓式塑性測定塑塑料的熔融率的標準試驗方法
  7. Abstract : based on the analysis of the mathematics models of saturation steam density and superheat steam density the paper states that the deviation of the detection on temperature highly affects the accuracy of intelligent flow totalizer. especially for saturation steam , the accuracy of the temperature detection circuit shall be designed higher than the accuracy of the instrument. thus a temperature detection circuit based on ratio method with high accuracy is introduced

    文摘:在分析飽和蒸汽和過蒸汽密度的數學模型的基礎上指出,溫度檢測的偏差對智能積算儀的精度影響極大,尤其是飽和蒸汽,測溫電路的精度應設為遠高於儀表的精度,同時引入一種基於比率法的高精度測溫電路。
  8. A parallel computing software is established independently. this software is a cell - centered finite - volume, structured grid, multi - block code which solves the equations governing inviscid and viscous flow of a calorically perfect gas or of an arbitrary mixture of thermally perfect gas undergoing non - equilibrium chemical reactions

    通過簡單的參數控制,該程序既可算二維、軸又巾彌和三維完全氣體,也可算化判卜平衡;既可算無粘,也可算粘性
  9. Through the research work of this article, it is shown that cfd technology can efficeintly instruct the design of indoor air distribution and evaluate indoor air quality and ventilating effect ; the distribution of heat sources have great impact on indoor air distribution ; under variable air volume condition, the indoor temperature and velocity fields are quite even and the thermo - environment is relatively good when using diffusers with coanda effect such as square diffuser and slot diffuser to supply air

    經過本文研究發現,利用cfd技術可以有效地對空調室內氣組織設進行指導,全面對室內空氣品質和通風效果進行評價。源分佈對于空調室內的氣組織具有極其重大的影響。在變風條件下,利用具有良好貼附效應的送風口如方型散器和條縫風口送風,空調室內的溫度場和速度場較均勻,室內的環境良好。
  10. With the impact test of conditioner airport and anti - dust mesh settings on heat exchange gas flow, the paper illustrates that the improper design may reduce gas flow, influence the refrigerating capacity of the system, and increase energy consumption

    摘要通過空調風口及防塵網設置對換影響的測試,結果表明,若空調風口及防塵網設不當,則可能造成氣減少,並影響系統製冷,增大能消耗。
  11. The methods of deciding water and hot watersupply design second flow imside of buildings include square root method, experience method and probability method

    建築內部給水、水設算方法有平方根法、經驗法和概率法等。
  12. The mathematical models set up for flow and heat calculations have been applied in the design work of intelligent flow or heat accumulators

    對于算的數學模型,已在各類智能積算儀的設中得到了應用。
  13. As the key parameters in flow and heat calculations, density ( ) and enthalpy ( h ), there is still lack of a definite mathematical model for such parameters " computing method

    但作為算中的關鍵參數密度( )和算中的關鍵參數焓值( h )的算方法,卻沒有一個明確的數學模型。
  14. Experiments on the gas flow patterns in the flowmeter prove that the algorithm used in arm digital gas mass flowmeter is capable of significantly improving the sensitivity of the heat sensor, hence superior in terms of the measurement of gas mass flow

    並將此演算法應用於以arm處理器為核心的數字式氣體質中實驗證明,該方法能夠明顯改善式傳感器的動態響應速度,實現其快速補償。
  15. Focusing on the performance evaluating and the design of tripropellant injector, adopting the cold test rig with background pressure supply, malvem particle analyzer, ccd photography system, tripropellant hot test - bed, numerical simulation software and auxiliary theoretical a nalysis, the d ischarge c haracteristic a s w ell a s a tomization p erformance o f the injector and the combustion performance as well as the mode - transition characteristic of thrust chamber are studied detailedly based on the 3 different structures of coaxial tripropellant injector, large numbers of important conclusions are gained

    本文圍繞三組元噴嘴的性能評定及設方法。採用反壓冷試臺、馬爾文測粒儀、 ccd高速攝影系統、三組元發動機態試驗臺、數值模擬程序及輔助理論分析等多種技術手段和研究方法,對三種結構的同軸式三組元噴嘴深入進行了噴嘴特性和霧化特性、推力室燃燒性能和轉工況性能研究,得到了大重要結果。
  16. Step with allmess gmbh by telephone : by + 49 4361 6 25 - 0, if it concerns prices to the high - quality offers like water meter, flow meter as well as waste water treatment units, water supply plants or also like calorimeters, flowmeter and measurement of volume

    Allmess gmbh是一家令客戶滿意的生產商和服務商,該公司提供新型的、專門的產品,例如污水凈化裝置、廢水凈化裝置,,給水、供水,水表、水表。
  17. Standard test method for determination of the thermal conductivity of anode carbons by the guarded heat flow meter technique

    用防護技術測定陽極碳傳導率的標準試驗方法
  18. As the dangerous position needed to be verified has been identified with the known heat flux profile and the characteristics of flow rate distribution, the metal tube temperature of the position can be obtained

    此方法克服了目前常用的電廠鍋爐壁溫算方法中校核點工質負荷並不一定互相對應的缺點。
  19. Standard practice for heat flow calibration of differential scanning calorimeters

    差分掃描校準標準實施規程
  20. Analysis of the test results of the rear - installed cooling system revealed that the overheat problem resulted from the measured cooling air temperature being higher and the coolant flow and transmission oil flow being smaller than the correct design value, and that the wrong location of the hydraulic oil cooler cannot completely meet the need of the cooling system

    通過對測試數據進行分析,確定了系統過的原因,即系統中測試獲取的冷卻風的溫度比設值高,冷卻水和傳動油的體積比設值小,而且液壓油散器布置位置錯誤。
分享友人