激光鏡 的英文怎麼說

中文拼音 [guāngjìng]
激光鏡 英文
laser mirror
  • : Ⅰ動詞1 (水因受到阻礙或震蕩而向上涌) swash; surge; dash 2 (冷水突然刺激身體使得病) fall ill fr...
  • : Ⅰ名詞1 (照耀在物體上、使人能看見物體的一種物質) light; ray 2 (景物) scenery 3 (光彩; 榮譽) ...
  • : Ⅰ名詞1 (鏡子) looking glass; mirror 2 (幫助視力或做光學實驗的器具) lens; glass 3 (姓氏) a s...
  • 激光 : [物理學] laser 激光靶 laser target; 激光報警器 laser avoidance device; 激光玻璃纖維 laser fibre; ...
  1. Cauterization of canine peripheral lung tissue withnd yag laser by thoracoscopy

    經胸腔熱凝肺組織的實驗研究
  2. To ensure the security of gi inspection, no approving method has been developed by far to drive the capsule endoscope but utilizing the natural peristalsis of gi tract. the uncontrollability of the capsule endoscope brings on some limitations in its functional extension in inspection, medication and surgery, such as temperature and ph measuring, medicament spraying, sampling, on - line sample analyzing, laser incising and rf cauterizing

    膠囊內窺目前還沒有實用的主動驅動方法,只能利用消化道自然蠕動作為膠囊內窺前進的動力。由於膠囊內窺不可控,限制了它的功能擴展,比如壓縮空氣噴藥、吸取組織樣品、在線樣品分析、切割、射頻燒灼等。完善的膠囊內窺系統需要在現有基礎上加入安全有效的驅動控制,可調整姿態、行進及定位,從而擴大膠囊內檢查的適應癥、安全性與多功能性。
  3. This paper analyses the coupling wastage in columniform wave guide gas laser, and gives the function between the coupling wastage of laser guide modulo eh11 and the position and radius of reflector

    摘要分析了圓柱形波導氣體器中的耦合損耗,給出了最低階波導模eh11的耦合損耗與反射位置、曲率半徑的函數關系。
  4. Detection : carbon - sulfur analyzer, oxygen analyzer, glazing machine, rockwell ( vickers ) hardometer, profile projector, surfagauge, scan electron microscope, laser conductometer, magna - check, universal measuring instrument, metallograph and image analysis system, abrasion tester, universal test machine and other advanced analysis and detection equipment and instruments

    檢測類:碳硫分析儀、氧分析儀、試驗室用拋機、洛(維)氏硬度計、輪廊投影儀、表面粗糙度測量儀、掃描電熱導儀、磁力探傷機、萬能測量儀、金相顯微及圖像分析系統、磨損試驗機、萬能試驗機及其它的先進的分析檢測設備和儀器等產品類。
  5. Laser confocal fluorescence microscopy

    共聚焦熒顯微
  6. Clsm confocal laser scanning microscopy

    共焦掃描顯微
  7. Laser scanning confocal microscope

    共聚焦掃描顯微
  8. Approach to application of laser scanning confocal microscope in bone morphometry

    共聚焦顯微在骨計量學中的應用
  9. Confocal laser scanning microscope technique and its application in dermatology research

    共聚焦掃描顯微在皮膚科的應用
  10. It is interesting to observe that the principle of operation for the "prism" coupler of fig. 3. 22b is being considered for extracting the output from lasers of the mesa type.

    我們將看到圖322b的「棱耦合器」工作原理正被考慮用來從臺面器獲得出,這是很有意義的。
  11. He is also an expert in various open urological surgery like the radical nephrectomy and cystectomy, as well as endo - urological surgery like the transuretheral resection of prostate, ureteroscopic pneumatic and holmium laser lithotripsy, minimal invasive percutaneous nephroscopic lithotripsy and laparoscopic surgery, like the laparoscopic adrenectomy and nephrectomy

    較熟練地掌握泌尿外科腔內手術,如經尿道前列腺電切術,輸尿管氣壓彈道碎石及鈥碎石術,微創經皮腎碎石術及各類腹腔手術,如腹腔腎上腺腫瘤切除術,腹腔腎切除術及腎盂成形術等。
  12. As for the sub - cellular locations of cortactin, laser confocal scanning microscope pictures shew that in cleavage stage, cortactin was distributed ubiquitously in the cytoplasm with the exception that in cells undertaking cytokinesis, positive stained signals were detected in the cleavage furrow

    在利用掃描共聚焦顯微進行的皮層蛋白亞細胞定位的觀察中發現,卵裂期,皮層蛋白在整個細胞質中分佈,在正在進行胞質分裂的卵裂溝中染色較強。
  13. Based pc, d / a convertor and 2 - dimension galvanometer scanning system, laser marking control system is built. coordinate data scanned and kept in the computer are transformed into the analog signals by d / a converter, then control the galvanometer to deflexion

    基於pc 、 d / a轉換器和二維振掃描系統搭建打標機控制系統,將存儲在主控計算機的掃描坐標點的坐標數據通過d / a轉換,將數字信號轉換成模擬信號來控制振偏轉。
  14. The emulsoid particle size and its distribution were determined by laser particle sizer. the composition changes of acr were inspected by ir, and the core - shell structure was observed by tem. the morphologyes of acr resin particles were inspected by polarization microscope at last

    通過粒度分析儀對所合成的乳膠粒徑及其分佈進行了分析測試,藉助于ir考察了所合成的acr的組成變化,並通過透射電對所合成的acr的核殼結構進行了驗證,最後藉助于偏顯微觀察了破乳乾燥后得到的acr粒子。
  15. Following laser exposure, the samples were fixed in 4 % glutaraldehyde and sent for histologic study using eosin - staining techniques for subsequent analysis with light microscopy

    照射之後,樣本固定在4的戊二醛中,曙紅染色後用顯微分析進行組織學研究。
  16. Testing method of main parameters for laser protective eyewear

    防護主要參數測試方法
  17. Image coordinate and galvanometer pendular angle are kept in the computer according to the f9 field lens characteristic, enter pupil excursion and f6 characteristic error are ignored, that the image of laser scanning point move acceding to unlinearity relation is deduced theoretically. for deducing the distortion, error compensation is considered in the software

    像點坐標與振擺角按f物特性的線性關系存儲在計算機,在忽略了入瞳漂移和f特性誤差后,從理論上推導出二維垂直振分佈中束掃描點的像點按照復雜的非線性關系運動,為了減少幾何畸變,在軟體設計中給出誤差補償。
  18. To reduce the marking distortion, using the vertical 2 - dimension galvanometer distributing and f field lens focalize, the distance of the second galvanometer to the machining plane is the focus f. to avoid too hign temperature to distroy the resonance cavity because of too long marking time, cooling system and self - protector is used in the design

    為減少打標畸變,採用垂直二維振分佈, f物聚焦,將束經第二個振反射後到加工平面的距離為焦距f ,為了避免打標時間過長,溫度過高破壞諧振腔,在設計中加上冷卻系統和自我保護裝置。
  19. The resonant box effect is the most important. in chapter five, we use the experimental setup constructed and the cavity decay time method to measure the total loss of a passive resonant cavity, and analyse the experimental data in very detail. we conclude that, in present experimental conditions it is the uniformity and stability of laser mirror to confine the precision and repeatability of experimental results

    第五章在建立起了連續波時間衰減法測量裝置的基礎上,進行了無源諧振腔總損耗的測量,仔細分析了實驗過程中的誤差因素,並指出在目前的實驗條件下限制測量精度和重復性的主要原因是激光鏡片的均勻性和穩定性不理想。
  20. This research paper is aimed at the measurement of high reflectivity of laser mirrors

    本文的目的是要實現激光鏡片的極高反射率測量。
分享友人