無變壓器的 的英文怎麼說
中文拼音 [wúbiànyāqìde]
無變壓器的
英文
transless-
Filling opening for immersed transformers without conservator, allowing the setting of a level indicator or a protection device. interchangeability dimensions
無存油箱有油標或保護裝置的浸油變壓器的注入孔.互換尺寸Watthour meters in moulded insulation case without instrument transformers, up to 60 a rated maximum current ; principal dimensions for meter terminal cover for poly - phase meters
安裝在最大額定電流可達60 a的無儀表變壓器模壓絕Watthour meters in moulded insulation case without instrument transformers, up to 60 a rated maximum current ; principal dimensions for meter terminal cover for single - phase meters
安裝在最大額定電流可達60 a的無儀表變壓器模壓絕The second, at the high frequency primary coil, when switch turn on with control signal ( the spwm pulse is modulated ), in the positive or negative semi - period of low frequency modulation signal, transformer coil with same direction voltage. the magnetic flux of transformer core will increase step by step. at the end, it leads to magnetic flux saturation
二、在高頻變壓器原邊,當開關管接收控制信號脈沖列(經調制的spwm波列)導通時,在低頻調制信號的正半周或負半周內,施加在變壓器繞組上的是同一方向的電壓,變壓器磁芯中的磁通可能將級進地逐漸增加,導致磁芯飽和,造成磁偏或單向磁化,導致低頻電信號放大失真或由於很大的磁化電流而無法正常工作。In the first part, the operation of transformer and of lc loseless snubber is analyzed
工作原理部分分析了變換器中變壓器的工作過程和無損吸收電路的工作原理。In the models, the iron core nonlinearly of the traction transformer and the magnetic hysteresis effect without the b - h curve are considered. having tested by digital simulation, the winding parameter has not changed in the state of external fault or magnetizing inrush etc. but the winding parameter has obviously changed in state of inter fault or inter - turn fault. ( 3 ) the rules three phases converted to two phases of traction transformer in electric railways are developed in this paper
( 3 )利用牽引變壓器磁鏈平衡方程,建立了基於系統辨識理論的雙繞組單相接線牽引變壓器、阻抗匹配平衡牽引變壓器及scott (斯科特)接線牽引變壓器的「灰箱」模型,該模型考慮了牽引變壓器鐵芯非線性和磁滯效應,但又不直接反映在模型中,並且無需鐵芯的b - h曲線數據。Firstly, the thesis briefly reviews the history of voltage and reactive power control technology, focusing on the defects of the equipment in use. then, with the theoretical analysis and the discussion on voltage and the characteristic of power system as well as the basic principle of voltage and reactive power control, the thesis makes a research on the character of voltage and reactive power control and interprets the controlling regularity of substation. in addition, with the consideration of the changes of transformer tips and the combined influence of capacity groups and reactive power and voltage, the thesis makes adjustment suggestion to the different operating - zones of voltage and reactive power
本文從降低網損和提高變電站自動化水平著眼,對變電站電壓無功控制應用方面的問題進行了研究,本文首先簡要回顧電壓無功控制的發展概況,著重指出了現有電壓無功控制裝置的缺陷;通過理論分析,在討論電力系統電壓、無功調節特點以及電壓無功總體控制原則的基礎上討論了變電站電壓、無功控制特性以及控制原理,給出了變電站電壓無功的控制規律;考慮了變壓器分接頭的變化及電容器組的投切對無功和電壓的綜合影響,針對電壓、無功的各種運行控制區域給出了相應調節策略。For the existing transformer cooling control system has many shortcomings such as the complicated system control circuit, the low reliability, the protection methods of blower fan being so simple, large control error, high fault rate, massive maintenance work and no method to realize telecommunication, this thesis develops a novel intelligent power transformer air - cooled control system based on the center of microprocessor through all - round technology analysis and research
本文針對變壓器冷卻系統使用常規控制系統存在的系統控制迴路復雜、可靠性低、風機的保護方式簡單而無法進行故障預測、主變壓器油溫測量精度低造成控制誤差大、故障率高、維護工作量大、無法實現遠程通訊等問題,經過多方面的技術分析和調研,設計開發了新型的以微處理器為核心的智能式電力變壓器風冷卻器控制系統。Sg 10 series transformer is harmless to environment, it is disassembled easily when useful life is end, the conduct material and core can be recycled, when protect environment well
對環境無害。當該種變壓器的有效壽命結束時,可方便地對其進行拆卸,並將導電材料連同鐵心一起回收,真正做到環保。On account of the disadvantages of the feedback reactive power compensator, a device of its simplified scheme is studied in this paper, in which the reactive power is adjusted by regulating the voltage of the low - voltage side of the transformer
由於這種反饋式補償方案存在一些問題,本文分析了它的簡化形式,即通過調節降壓變壓器低壓側的母線電壓來調節濾波器的無功出力的補償方案。Specifications for variable - ratio transformers having current collectors which are moved transversely in the direction of the windings
裝有可在繞線方向橫向移動集電器的可調無線電變壓器Gb1094. 5 - 85 power transformers part 5 ability to withstand short circuit only applies to power transformers, not to balanced transformers. if short - circuit test on balanced transformers can be performed by means of single phase supply instead of three phase supply, and other special transformers can also be done in this way, so it is very significant to improve test capacity of transformer laboratory in our country
變壓器的短路強度只能通過短路試驗來驗證,國家標準gb1094 . 5 - 1985 《電力變壓器第5部分承受短路的能力》只適用於電力變壓器,對平衡變壓器等特殊變壓器並無具體規定,對于平衡變壓器,如果可以用單相電源預先短路法模擬三相電源的短路試驗,那麼其它特種變壓器的短路試驗也可以參照進行,這對提高我國變壓器試驗室的試驗能力具有重要意義。Many practical factors, such as effects of line fuses protection, disconnected switches, scheduled maintenance, spare electrical source, spare transformers in distribution system, are considered in the assessment arithmetic. in the assessment, it is more practical that low - voltage power system is equivalent to an element on the lateral section of mid - voltage system. especially, the minimal cut - sets are divided into direct cuts and indirect cuts, which makes the effects of elements in cuts on system more legible and exact
演算法考慮了分支線熔斷器保護、隔離開關、計劃檢修、備用電源、有無備用變壓器的影響,將低壓系統等效為中壓系統分支饋線上的一個等效元件進行評估,使得該方法更符合實際,特別是,將最小割集分為直接割集和間接割集,使割集元件的影響更加清晰準確,並以c + +語言編制了計算軟體。Its being used can form high efficiency insulated switching power supply without using utility power transformer. the switching power ic is selected firstly in the design of high power switching power supply, precision switching power supply, application specific switching power supply and so on in the world, which has been making switching power supply short, small, light and thin the control techniques of dc - dc switching converters are completely described and analyzed
單片開關電源管理集成電路具有高集成度、高性價比、簡單外圍電路、優越性能指標等優點,能構成高效率無工頻變壓器的隔離式開關電源,目前已成為國際上開發中、小功率開關電源、精密開關電源、專用開關電源以及開關電源模塊的優選集成電路,使得開關電源正朝著短、小、輕、薄的方向發展。Were there no transformers to adjust the voltage, long - distance transmission of electricity would be impossible
若無變壓器來調節電壓,遠距離輸送電力是不可能的。Through analyzing the mathematical model of two winding transformer, the effect after on - load tap changing on voltage and reactive power balance at each side, effect of shunt capacitor compensation on voltage and reactive power balance in substation the relation between transformer tap adjusting and shunt capacitor switching in practical grid operation were discussed
摘要通過對兩卷變壓器的數學模型進行分析,討論了兩卷變壓器抽頭調整后,變電站各側電壓及無功功率的變化;無功補償對變電站各側電壓及無功功率的影響;實際電網生產運行中,無功補償與變壓器抽頭的配合調整。With the development of substation automation and power system automation, especially the progress of voltage and reactive power centralized control in large - scale power system, the controllers of voltage and reactive power ( vqc ) for substation based on scm ( single chip microcomputer ) will not been adapted. this paper presents a new vqc application based on industrial pc
變電站綜合自動化、電網調度自動化和區域性電壓無功集中優化控制的發展,以及近幾年城鄉電網改造中配置四臺主變壓器的大型變電站的出現,都對變電站電壓無功綜合控制系統( vqc )提出了越來越高的要求。On - load tap - changer of transformer can work under load, transfer quickly, change one class voltage about 3 - 6 ms each time ; switch can be operated by hand or electrically - driven and distant place operate while being electronic too, easy to realize automatic management ; transfer and keep relatively heavy range is generally more than 15 % ; switch and voltage transformer structure are more complicate than others, make man - hour and material increase, the cost is relatively high
變壓器的有載調壓能帶負載調壓,調壓速度快,每調換一級電壓約3 6s ;開關可手動、電動操作,也能遠方電動操作,便於實現自動化管理;調壓范圍較大,一般為15以上;開關和變壓器結構比無勵磁調壓的復雜,製造工時和材料增多,成本較高。The test methods of short circuit and overload protection of non - inherently short - circuit proof transformer and fail - safe transformer
無危害式安全變壓器的短路和過載保護試驗Watthour meters in moulded case without instrument transformers up to 60 a rated maximum current - part 5 : principal dimensions for terminal cover
最大額定電流在60a以下無儀表變壓器的模壓殼體的電度分享友人