熱量漏泄 的英文怎麼說

中文拼音 [liánglóuxiè]
熱量漏泄 英文
heat leaks
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : Ⅰ動詞1 (從孔或縫中滴下、透出或掉出) leak; drip 2 (泄漏) divulge; disclose; leak 3 (遺漏) le...
  • : Ⅰ動詞1 (液體、氣體排出) let out; discharge; release 2 (泄露) let out (a secret); leak (new...
  • 熱量 : quantity of heat; heat quantity; amount of heat熱量測量 calorimetry; 熱量單位 thermal unit; heat ...
  1. To prevent magnetic leak, improve the abrasiveness and the anti - eroding ability, the author have spent lots of time in researching the hot spraying method and acquired many practical useful data and experience

    為了防止,增加活塞桿的耐磨性和抗腐蝕性,本文還對噴塗工藝進行了研究,並摸索出了大實際有用的數據及經驗。
  2. Under special conditions such as low partial load / deep vacuum, unexpected high air leakage resulting in a major temperature difference ( above 10 c ) between the steam exhaust turbine temperature and all air - take off temperature measurement, the suction capacity can be improved by using 2 main ejector simultaneously

    在特殊條件如局部低載荷/極端真空,不正常的交換,意想不到的高空氣導致的在蒸汽排氣溫度和抽空溫度測上產生的嚴重溫差( 10 c以上) ,用兩臺主抽汽器同時工作可以提高抽氣
  3. Test results indicated : with the hoist of altitude, the increase of ice amount and the rise of pollutant, the average flashover voltage reduced. the character exponent generally depends on the insulator profile, ice amount, ice state and pollution severity etc. by means of a high - speed camera, a data acquisition system and high voltage test facilities, a series of the flashover processes on ice surfaces were record. the experimental results form this study and the subsequent theoretical analyses suggested : the thermal ionization of the air in front of an arc root resulted in arc movement ; the electrostatic force had an auxiliary effect of impelling arc propagation ; the electrical

    通過對攝像機、數據採集系統及高壓試驗裝置記錄覆冰絕緣子表面閃絡電弧的發展過程的試驗結果進行理論分析得出:弧根周圍空氣的電離導致了電弧的發展,靜電場力對電弧的發展起到了加速作用,電擊穿僅發生在閃絡最終的跳躍階段;通過測閃絡過程中的放電電壓、電流、閃絡時間、覆冰水電導率、電弧長度及電弧半徑等參數,得到了不同階段電弧(電弧起弧階段、電弧發展階段及完全閃絡)的發展速度、臨界電弧長度均隨覆冰水電導率的增加而減小。
  4. The study also shows that the unidentified steam leak quantity is not exceeded to 0. 3 % of the main steam flow after the system is isolated. so the steam leak of the thermal system is little, and the system is sealed well

    研究結果還表明,系統隔離后不明均不超過主汽流的0 . 3 % ,整個力系統外較少,系統嚴密程度較好。
  5. An innovative company, tyco thermal controls offers a complete range of product offerings and system solutions, ranging from heat - tracing systems, specialty heaters and floor heating to fire & performance wiring, temperature measurement and leak detection

    通過不斷創新,泰科控為客戶提供完整的產品系列並度身定製完善的系統解決方案,其中包括:電伴系統、地板電採暖、礦物絕緣耐火電纜、檢測、溫度測及特種加等。
  6. In the rotor design, it makes a detailed calculation for all the geometry feature parameters including geometry dimensions, contact line length, blowhole area and flow cross - section area and the thermodynamic feature parameters such as cooling capacity, shaft power and so on

    在轉子設計方面,對全部幾何特性參數,包括幾何尺寸、接觸線長度、三角形面積和面積利用系數等以及包括製冷、軸功率等冷水機組力特性參數進行了詳細計算。
  7. The energy equation of the thrust chamber wall was developed by omitting radical heat conduction and only considering the radiation heat transfer of the four chambers, the radiation leakage through nozzle exit, the axial and circular heat conduction

    忽略徑向導,考慮推力室外向的相互及自身輻射交換、內壁經噴口的輻射以及周向和軸向的傳導,建立了推力室壁的能方程。
  8. Excess heat from the combustion chamber is also a problem, often leaking to other components of the engine

    另外,燃燒室排出的過氣經常到發動機的其他零件中,這也是一個問題。
分享友人