畸變基準 的英文怎麼說

中文拼音 [biànzhǔn]
畸變基準 英文
distortion standard
  • : Ⅰ形容詞1 (偏) lopsided; unbalanced2 (不正常的; 不規則的)irregular; abnormalⅡ名詞[書面語] (零...
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  1. In the digital inverter, we adopt the technology of digital dynamic waveform correction, which can compensate the delay between control signal and output waveform, and ensure the accuracy of control. at the same time, the technology of digital dc component adjustment was introduced, by which we can exactly compensate the control signal, and realize adjusting dc component of output on the premise of output performance

    於dsp的數字換器平臺中,採用全數字波形校正技術,完全補償了控制信號延時、功率管開關延時以及死區時間對輸出spwm波形所產生的,充分保障了換器控制的確性;採用數字直流分量調節技術,可以精確地對控制信號進行補償,在充分保證輸出性能的前提下,實現了輸出直流分量的調節。
  2. In this paper, a method assessing harmonic impedance by synchronously layered distortion waves is proposed, which is based on the " fluctuations method " - a simple and effective means. however the method is based on the fourier transform, which can just precisely analyze the signals whose cycle is integer times as broad as that of fundamental wave. with sampling windows widening, the variations of distorted signals in a fundamental period are weakened

    本文是以一種被廣泛採用的非干預式諧波阻抗估計方法? ? 「波動量」法,的礎上,針對現有方法以直接的fourier換為分析工具,只能對波周期的整數倍窗口采樣信號進行分析,信號在一個波周期內的化隨采樣窗口增大而被弱化,並且,諧波次數越高,解析度就越低,大大限制了諧波阻抗估計的確性的提高。
  3. Many registration experimental results can illustrate the performance of this method. we also study on the feature and deformations of remote sensing images. aiming at infinite length images with local distortions, we suggest a sequential stream - like registration method

    在研究遙感圖像特點和失配方式的礎上,針對具有局部幾何和無限長特點的遙感圖像,提出了一種持續地流水線式的配方法。
  4. The detecting method of dvr is different from harmonic and reactive current detecting methods. it need detect not only total harmonic distortion but also the difference between fundamental wave component and reference value

    Dvr的檢測方法與諧波、無功電流的檢測不同,不但需要檢測出除波分量之外的總分量,還要檢測出波分量與值之差。
  5. It shows that a disadvantag ekists when a crsi is used to measure a step structure in a wavefront, but it is useful to adjust a crsi system with lcslm. 4. according to the didriction effect of an aperture, the spatial resolution of our crsi was analyzed and the transform function of our crsi was calibrated by using the psd method of a step wavefront. and some factors which are associated with the accuracy of our crsi were analyzed too

    四、從光學系統衍射效應的角度分析了本文建立的環路徑向剪切干涉儀的空間解析度,並利用波前功率譜密度的概念對該干涉儀的空間頻率響應特性進行了標定,分析了限制該干涉儀測量精度的主要因素以及徑向剪切比與測量精度的關系,並指出了該干涉儀的測量范圍,結果顯示該干涉儀本上可用於確測量中低頻段的波前
  6. Distortion correction based on calibration mapping

    於校映射的校正
  7. - 2. in order to accomplish the extraction measuremellt of distorted wavefront on specific plane of a laser beam, a crsi ( cyc1ic radial shearing interferometer ) based on relay imaging technique was built. the experiinental result on this crsi shows it can used to test the spatial mid and low frequency wavefront distortion

    二、為了實現激光光束在確定平面上的波前確檢測,採用中繼成像技術建立了一套於空間相位調制的環路徑向剪切干涉波前傳感硬體系統,實驗證明,它可用於中低頻段波前的檢測。
  8. What the subject researching is that power energy should be measured with base wave ammeter to power systematic nonlinear user ; and that it is high veracious by base wave ac parameters measurement method to those not bad contaminative. it is well known that all kinds of ac parameters including of base wave and harmonics, but the content of harmonics in power systems increase largely with the mass disturbance to power using high - power electric equipment. which makes wave shape of voltage and current aberrence, so the measurement veracity and reliability decreased largely. at the same time brings out serious infuency to safe run of power system and electric equipment. the power which any non - linear loads consumes can be divided into two sides, one is base power absorbed in power and the other is minus harmonics power

    本課題所研究的問題是針對電力系統非線性負載用戶採用波電度表來計量電能;而對諧波污染不嚴重的線性用戶採用波交流參數測量的方法仍然具有較高的確性。眾所周知,各種交流參量都包含波和各次諧波,然而隨著電力電子技術的迅速發展,大功率的用電設備對電網的干擾也是越來越嚴重,導致電力系統諧波含量迅速增長,使電壓和電流的波形產生嚴重,測量的確性和可靠性都大大降低,同時也對電力系統和用電設備的安全運行帶來嚴重的影響。任何一種非線性負載所消耗的功率都可以分為兩部分,一部分為從電網中吸取的波功率,另一部分則是負的諧波功率。
分享友人