磁場線圈 的英文怎麼說

中文拼音 [chǎngxiànjuān]
磁場線圈 英文
field-coil
  • : 名詞1. [物理學] (磁性; 能吸引鐵、鎳等的性質) magnetism 2. (瓷) porcelain; china
  • : 場Ⅰ名詞1 (平坦的空地 多用來翻曬糧食 碾軋穀物) a level open space; threshing ground 2 [方言] (...
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 圈名詞1. (養豬羊等牲畜的建築) pen; fold; sty 2. (姓氏) a surname
  • 磁場 : [物理學] (傳遞運動電荷或電流之間相互作用的物理場) magnetic field
  • 線圈 : [電學] coil
  1. Positrons and antiprotons can individually be stored in a device called a penning trap, which uses a combination of magnetic and electric fields to hold charged particles in a vacuum

    正電子和反質子能單獨地被儲存在一個稱作環形裝置中,藉助和電的一個聯合作用儲存真空收集來的粒子。
  2. As a result, the electromagnetic field intensity is changed accordingly and fluctuating current in the damper coil is created. damping force is mostly produced because of the phase difference between fluctuating current and displacement of rotor. the formulas of fluctuating current and damping coefficient are deduced theoretically, and the calculated results are consistent with the experimental results

    通過分析發現電阻尼器內由於轉子渦動時變化的而產生的波動電流與轉子位移間的相位差是產生阻尼的主要原因,推導了波動電流、阻尼系數的計算公式,並通過實驗展示了被動式電阻尼器的阻尼效應。
  3. Power mosfet is adopted to switch heavy current of magnet core in order to control rotating magnetic field effectively

    為了使得到有效控制,本文採用功率nosfet實現電大電流的開關。
  4. Study on agnetic field of a circular current and helmholtz ' coils

    圓電流和亥姆霍茲的研究
  5. Being a method of time - domain electrical magnetic surveying, the transient electromagnetic method ( tem ) can transmit first pulse electromagnetic field to underground making use of loop or electrical source and receive secondary induction field during of the pulse intermission

    瞬變電法是一種時間域電測量方法,是利用不接地回或接地源向地下發送一次脈沖,在一次脈沖的間歇期間,採用不接地接收感應二次
  6. As the single rectangular coil is the routine induction probe, the system is simulated based on the theory of a - v - a. the perfect induction field is studied. the corresponding relations between the slots and the field are also analyzed, as well as the measurement scale is given here

    )描述下交變測量技術單矩形激勵形式下的數值模擬模型,從量檢測的角度出發,分析了無缺陷情況下該系統的電分佈特性,以及有缺陷情況下缺陷與分佈的對應關系以及缺陷檢測的數值范圍。
  7. The relations between relative measurementerror resulting from temperature and heat distensibility coefficient of coil ’ s framework andwindingcoilwerecarriedout. theinfluenceofelectromagnetisminterferenceontheaccuracyof rogowski coil, as well as the effect of temperature on integraph, were studied. somemeasures based on the above investigating results were proposed to insure the precision ofrogowski coil sensor head, such as the selection of materials and facture methods, improvment of technics and design of additional compensation

    利用建立的rogowski的數學模型對溫度和外界干擾的影響進行了分析,得出了溫度造成的相對誤差與骨架和繞組熱膨脹系數之間的關系;從兩個方向上分析了干擾精度的影響;分析了溫度對積分器的影響等。
  8. The oscillatory current flowing in the coil produces an oscillating magnetic field.

    流過的振蕩電流產生一個振蕩
  9. Superconductivity - ac loss measurements - total ac loss measurement of cu nb - ti composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method

    超導性.交流電損耗測量.用拾波法測量暴露于橫向交流的cu nb - ti合成超導導的交流電總損耗量
  10. Superconductivity - part 8 : ac loss measurements ; total ac loss measurement of cu nb - ti composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method

    超導性.第8部分:交流電損耗測量.用拾波法測量爆露于橫向交流中合成超導導的交流電總損耗量
  11. Superconductivity - part 8 : ac loss measurements - total ac loss measurement of cu nb to composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method

    超導性.第8部分:交流電損耗測量.用拾波法測量暴露于橫向交流的銅鈮復合超導導的交流電總損耗量
  12. This paper presents our research in actuating in - vivo micro - robot based on the capsule endoscope platform by the external power. while seeking secure driving method we take several factors into account, such as driving environment, power transmitting and consuming, motion requirement and controllability, and locating technique. we mainly deal with driving the capsule with spatial gradient magnetic field, so we employ combined electro - magnetic coils, including gradient coils and homogenous coils, which have rotational dof around a translatable patient bed, to compose a controllable uniform gradient which act on the permanent - magnet embedded robot, thereby get an appropriate spatial force and torque to fulfill the anticipant locomotion such as move, stop, pitch and yaw

    基於驅動環境、能量供給和消耗、驅動動作要求及驅動安全性與可控性,定位方案等多方面考慮,尋求安全可靠的腸胃檢查微機器人的外部驅動控制方法,並著重研究直接利用外力驅動微機器人:在微機器人內部嵌入永性體,利用體外的組合電產生加載電流控制的驅動,其中外部的電由多組梯度和勻組合構成,通過繞病床的旋轉以及病床的平移共同控制微機器人所在位置的強度及梯度,作用於微機器人內嵌體以獲得空間意義上的必要驅動力和調整轉矩,從而有效地完成驅動動作要求。
  13. No adjustment needed. the magnetic coil is static and does not need dust brushes or similar protective devices. all components are located in the main body ( the clutch housing ) for fast and easy installation with no need for further adjustmeng

    不需要做調整. . .由於是磁場線圈靜止型,可以免去灰刷等的維護工作,而且所有的零件全部安裝于主體(離合器輪殼) ,可以很簡單地安裝到機械中,不需要做調整。
  14. Some correlative designs and experiments are finished before the microwave test experiment. the property of a finite long magnetic coil is studied and the coil magnetic field circuit is constructed for the experiment of microwave. a digital two - channel trigger device is designed and successfully applied in the experiment

    為了微波實驗的順利進行,我們設計並加工了磁場線圈,研製了控制磁場線圈迴路觸發和強流電子束加速器觸發同步的兩路數字同步觸發器,研製了測量電子束流的法拉第筒,並成功地將這些設備應用於微波實驗研究。
  15. For the external - magnetic field mid, the cathode with improved structure works as a " close " magnetic coil that effectively increases the continuity and uniformity of magnetic field, and then ensures the stability of dense anode plasma formation

    對于外絕緣離子二極體,改進的陰極形成單匝「閉環」磁場線圈,有效地提高了的連續性和均勻性,保證了稠密陽極等離子體的穩定形成。
  16. The advantage of this method is that, the compensation loop is applied for eliminating the change of toroidal flux produced by the toroidal coils and the adjustable structure can be used to decrease the error signals come from the poloidal field

    該方法的優點是補償有效地消除了縱產生的通變化,而調節機構能降低來自極向的誤差信號。
  17. The maximum temperature rise of these coils is also estimated from the thermo - hydraulic condition of the magnet operation

    並根據體運行的熱工水力條件估算出極向在等離子體放電過程中的最高溫升。
  18. It is found from the experiment that under the conditions of peak magnetic field of 0. 57t, beam pulse fwhm ( full width of half maximum ) of 44ns, a microwave radiation pulse with fwhm 25ns and whole width of 35ns is produced, when the intensity of the guiding magnetic field rises, the peak microwave power changes little but the width of the pulse reduces. the a - k gap also has obvious influence on the microwave radiation, the stable and higher microwave output is obtained under suitable gap

    實驗中還發現,在峰值0 . 57t和束流半高寬44ns情況下,得到了25ns半高寬和35ns底寬的微波脈沖信號,隨著導引增加,微波信號幅值基本不變,但國防科學技術大學研究生院學位論文是微波脈沖寬度會逐步減少;實驗中還發現磁場線圈位置有一定的軸向調節范圍,說明在軸向分佈的一定變化范圍內,器件都可以正常工作,這對以後的永系統導引的微波實驗有利。
  19. From magnetic fields in pf coils of east expressed as elliptic integrals, the heat load of pf coils during plasma discharge is determined

    摘要通過求解橢圓積分,計算了east極向系統的分佈,從而計算出極向在等離子體放電過程中的熱負荷。
  20. The design of lower - order tabulate shim coils for mri system

    共振成像系統中低階平板式勻的設計
分享友人