磁諧振 的英文怎麼說

中文拼音 [xiézhèn]
磁諧振 英文
magnetic resonance
  • : 名詞1. [物理學] (磁性; 能吸引鐵、鎳等的性質) magnetism 2. (瓷) porcelain; china
  • : Ⅰ形容詞1 (和諧) in harmony; in accord; in tune 2 (詼諧) humorous Ⅱ動詞(商量好; 辦妥) come t...
  • : 動詞1. (搖動; 揮動) shake; flap; wield 2. (奮起) brace up; rise with force and spirit
  1. The main features of the apparatus are focus on small volume, light weight, no iron core, no magnetic saturation and no ferreous resonance, moreover, related advantages such as the large range of transient and frequency response, excellent electrical magnetic compatibility, oil - free configuration, reliable insulation structure, are all the trends of current transformer in the future. meanwhile, it should agree with the future power gauge and digital, computer, automatic relay protection. it will meet the demand of digital power network

    它具有體積小、重量輕;無鐵芯、不存在飽和與鐵磁諧振問題;動態響應范圍大,頻率響應寬;抗電干擾性能強;無油化結構、絕緣可靠、價格低等優點;是未來電流互感器發展的方向,是新一代電力數字網發展的需要,適應電力計量和保護數字化、微機化和自動化發展的潮流。
  2. Digital simulation analysis of ferroresonance of electromagnetic potential transformer based on matlab

    磁諧振數字模擬分析
  3. Iron - magnetic resonance of electromagnetic - type potential transformer of 10 kv power system for yamzho yumco pumped storage station

    系統電壓互感器引起的鐵磁諧振及消方法
  4. The principle and application of jszg anti - ferro resonance triphase voltage transformer

    抗鐵磁諧振三相電壓互感器的原理和使用
  5. Harm and proventive measures of ferromagnetism resonance for the voltage transformer in power system

    磁諧振的發生對電壓互感器的危害及其預防
  6. The devices for detecting phase - to - ground fault in ineffectively grounded systems are seldom functionary at present. based on thousands of experiments in high - voltage laboratory in north china electric power university, the reasons for misjudgment and the effective measures to avoid it are presented in this paper : to change pt connection form to prevent from ill - effects of ferro - resonant overvoltage ; to increase soft measures to resist against interference ; to adopt neural network method to obtain the virtual value of the detect way

    依據上千次實驗,我們找到了一些導致選線誤判的影響因素,並提出幾點防止誤判的措施,包括改變pt接線方式,避免鐵磁諧振對選線的影響;通過對故障檢測方式的處理和使用連續判斷技術增強裝置的軟體抗干擾能力;嘗試採用神經網路演算法設定選線方法的有效域等。
  7. Cause analysis and counter - measures of bus voltage transformer

    所致鐵磁諧振過電壓分析及抑制
  8. Analysis of resonance overvoltage due to electromagnetic pt

    式電壓互感器鐵磁諧振事故分析及措施
  9. Electron paramagnetic resonance

    電子順磁諧振
  10. Casualty analysis of ferromagnetic resonance causing the burn of voltage transformer

    磁諧振導致電壓互感器被燒壞的原因
  11. Ferroresonance over - voltage on power transformer and its prevention

    電壓互感器鐵磁諧振過電壓及防止
  12. Harm of iron magnetic resonance of valtage transformer and countermeasures

    電壓互感器鐵磁諧振的危害與措施
  13. Key points in application of jszbf type anti - ferromagnetic resonance voltage transformer

    型抗鐵磁諧振電壓互感器應用中需注意問題
  14. Analysis of ferromagnetic resonance produced in voltage transformer of power distribution system

    供電系統中電壓互感器鐵磁諧振現象分析
  15. For the former has inductance winding and ferromagnetic material, its measurement range is restricted by saturation, so it has a narrower range of frequency. being an inductance, it has the possibility of resonance

    由於電式電壓互感器帶有電感線圈和性材料,測量范圍受鐵心飽和的限制,傳輸頻帶不夠寬;作為感性元件,存在鐵磁諧振的可能,可靠性差。
  16. By adopting resistance divider, voltage sensor designed in this topic has no ferromagnetic resonance, overcome saturation, has no load sharing, and is permitted to short and cutoff in circuit, so it has high reliability

    本課題所研究的電壓傳感器採用電阻分壓器原理,不存在鐵磁諧振,克服了鐵心飽和,不再有負荷分擔,短路和開路都是允許的,具有高的可靠性。
  17. Based on the analysis of the paper, we can draw the conclusion that this device has several issues to be solved to put into use, such as low filtering capacity, large bulk and area the device occupies, complexity of connection, and the hazard of ferro - resonance existing when switching without disconnecting the circuit of the step - up transformer

    經過分析發現,這種補償方案存在一些問題,如濾波能力低,補償裝置體積大,佔地面積多,接線復雜;並且如果在投切過程中不將升壓變壓器高壓側迴路斷開,存在著發生鐵磁諧振的危險。
  18. This forms a unity of the protective equipment and type selection to power network configuration and setting coordination that ensures the safe and reliable operation of power network extremely. after analyzing the first operation mode of yuncheng power network, the first and the second equipment configuration and operation, this paper sets up a scheme on setting and coordination of yuncheng power network and attention pointing on maintenance, and checks out equipment operation. the scheme reasonably uses the regulation procedures on relaying protection and automatic equipment setting coordination promulgated by china ministry of energy

    本文即在對運城電網一次系統運行方式,一、二次設備配置,鐵磁諧振對保護影響分析的基礎上,合理運用部頒《繼電保護及安全自動裝置運行整定規程》 ,兼顧繼電保護的四性要求,制定出運城電網繼電保護整定方案及設備運行維護校驗注意事項,旨在總結鐵磁諧振對保護影響及保護應用過程存在的實際問題和解決方法,尋找區域電網繼電保護安全穩定運行的基石,以提高電網繼電保護安全穩定運行水平。
  19. Analysis and prevention of ferromagnetic resonance between voltage transducer and switched fracture capacitor

    電壓互感器與開關斷口電容鐵磁諧振的分析與預防
  20. Analysis of series ferromagnetic resonance between electromagnet - induced voltage transducer and switched fracture capacitance

    式電壓互感器鐵磁諧振的分析與對策
分享友人