耐受電壓 的英文怎麼說

中文拼音 [nàishòudiàn]
耐受電壓 英文
withstand voltage
  • : 動詞(受得住; 禁得起) be able to bear or endure
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 壓構詞成分。
  • 電壓 : voltage; electric tension; electric voltage
  1. Power frequency withstand voltage between phases, to earth insolating fracture : 95kv 110kv

    工頻耐受電壓相間對地隔離斷口: 95kv 110kv
  2. Lightning impulse withstand voltage between phases, to earth insolating fracture : 185kv 215kv

    沖擊耐受電壓相間對地隔離斷口: 185kv 215kv
  3. Smart materials and structure have definite requirements of sensor components and driving components, for example, they can adhere well to the matrix and have higher strength, fatigue strength, more broad scope of frequency response and faster response speed, etc. piezodielectric ceramics have characteristic of easily preparing, heat - resistance, wet - resistance, high strength and broad scope of frequency response, etc. furthermore, it has piezoelectric effect and inverse piezoelectric effect, namely it can produce electric potential energy when it is transformed by mechanical strength and its mechanical dimension can be transformed when voltage is put on it

    陶瓷能與基體材料很好結合,具有制備容易、熱、濕、強度高、頻響寬等特點,另外它具有正效應和逆效應,即當它到機械力變形時,能產生勢,對它施加時,能改變其機械尺寸,因此它在智能材料結構中既能用作傳感元件又能用作驅動元件。
  4. Capacitance between any two terminals in the installation should no more than 1. 06. 3. insulation level of installation : for rated voltage of 6kv installation, it can endure 23kv rms for 1 min between the phrase to phrase or phrase to earth of main circuit ; for rated voltage of 10kv installation, it can endure 30kv rms for 1 min between the phrase to phrase or phrase to earth of main circuit ; it can be endure 2kv rms for 1 min between auxiliary circuits of installation

    3 .裝置的絕緣水平: 6kv額定的成套裝置,其主路相間及相與地之間,工頻耐受電壓方均根值23kv , 1min 10kv額定的成套裝置,其主路相間以及相與地之間,工頻耐受電壓方均根值30kv , 1min成套裝置輔助路工頻耐受電壓方均根值2kv , 1min 。
  5. The shorter the interval between the two pulses of the current wave, the fewer strikes the varistors can endure. at the same time, the dc ljima changes fast - slowly - fast alone with the experiment continuing. microstructual disorder, such as variations in the height of the electrostatic potential at grain boundaries and electrode protrusions into the zinc oxide varistors, causes substantial temperature rise in a microscopic region around the defect and is the source for failure

    的多重閃擊對雷保護器件的影響更加嚴重,本文首次採用不同間歇時間雙脈沖流沖擊對氧化鋅阻進行了多次試驗,試驗表明:氧化鋅阻在雙脈沖流沖擊下更容易出現老化破壞現象,間歇時間越短,阻能的沖擊次數越少;此外,直流u _ ( 1ma )值隨沖擊次數的增加具有快一慢一快的下降過程。
  6. Rated switching lightning impulse withstand voltage

    額定操作雷沖擊耐受電壓
  7. The tests of e - o applications by our flux ktp has been realized, the results showed : optical waveguides fabricated by using an ion - exchange process, which have an exchange - ion concentration depth profile and refractive - index profile, is close to a complementary error - function distribution, optical homogeneity and device thermal stability is much better. amplitude modulation switch formed by our flux ktp has the contrast ratio of 150 : 1 and insert loss is 2. 5 % at 1064 nm. high quality optical pulse with 1 ns width was cut successfully by using an e - o modulator from a laser pulse with 50 ns width, this modulator had run for three years, and the crystal did n ' t blackened, it showed our low conductivity flux ktp can endure high modulation voltage for a very long time

    Ktp晶體的光應用試驗表明:用離子交換法製作的光波導,其離子交換濃度、折射率變化符合餘弦誤差函數,光學均勻性以及器件的溫度穩定性較好;製作的強度調制光開關,消光比為150 : 1 ,對1064nm激光的插入損耗為2 . 5 ;製作的光調制器用於激光脈沖整形試驗,從脈沖寬度50ns的激光脈沖削出脈寬1ns的高質量光脈沖,該光開關經過長達三年多的使用,沒有出現晶體變黑現象,說明本實驗的低導率ktp晶體能夠長時間的調制
  8. Based on instance of mania project, the article raises an insulation coordination method for high elevation zone and the criterions fulfilling the insulation coordination conditions. it also has calculated the demanding values of withstanding voltage of all voltage levels equipment, and the results of outer insulation coordination. at the mean time, it proves the success of applying " humidity ratio " integrated emendation method in the mania project

    文中又根據滿拉工程實例,提出適合高海拔地區使用條件的絕緣配合方法及滿足絕緣配合條件的判據;採用「比濕」綜合校正法計算了滿拉工程各級設備耐受電壓要求值及外絕緣配合成果,同時也證明「比濕」綜合校正法在滿拉工程應用的成功。
  9. The conference attracted high attention from schneider electric. mr. russell stocker, the zone director of greater china, as a special guest, presented at the conference and made a speech at the opening ceremony. mr. he minghui, the director of energy sales team, mr. chen gang, the director of medium voltage business activity, and mr. sjamsu zen, the director of transformer business activity participated the conference

    本次大會到了施氣的高度重視,大中國區總裁施瑞修先生率領著能源市場銷售部總監何明暉先生、中事業部總監陳鋼先生和變器事業部總監陳書人先生作為會議特別嘉賓出席了會議並在開幕式上致辭。
  10. It compares and analyses the equipment test voltage emendated to standard atmosphere conditions with the equipment nominal withstanding voltage. and then it concluded that : the emendation value educed by " humidity ratio " integrated emendation method is basically equal or close to the equipment nominal withstanding voltage ; but the values by two traditional emendation methods are mostly higher. it also proves that, " humidity ratio " integrated emendation method is more perfect than any other methods, and it can reflect the influence degree of atmospheric parameters on electrical equipment outer insulation discharge voltage actually

    文中選擇「比濕」綜合校正法和兩種傳統校正法,分別對西高所為羊八井、拉薩、羊湖110kv變所設備所做的人工氣候室模擬試驗數據及雲南中試所做的zs - 110工頻放試驗數據進行校正計算,將試驗的校正值與試驗設備的標稱耐受電壓水平進行比較分析;認為: 「比濕」綜合校正法的校正值與設備耐受電壓水平基本相等或接近,而兩傳統校正法的校正值大多高於設備耐受電壓水平;進一步證明, 「比濕」綜合校正法是目前諸多校正法中較為完善的,能真實地反映大氣參數對氣設備外絕緣放的影響程度的校正法,在高海拔力工程設計中應推廣應用。
  11. The advantage and disadvantage of two kinds of principle of the external insulation configuration using contamination tolerance voltage and the rate of distance of voltage creepage is analyzed. the principles and measures of external insulation configuration of power transformation device is put forward at the present time. the technical measure against contamination flashover of power transmission and transformation device in electric network in south of hebei province is studied and determined

    分析了利用污穢耐受電壓或爬比距選擇外絕緣配置這兩種原則的優勢和存在的問題,提出了現階段輸變設備外絕緣配置原則和措施,研究制定了河北南網輸變設備防污閃技術措施。
  12. At the exhibition for new technologies and new products, the booth of schneider electric was swarmed with people. all sorts of medium voltage distribution products were demonstrated at the site. everyone benefited a lot from the engineer s elaborating and the mutual information exchange

    與此配合的新技術新產品展示會上,施氣的展位人頭攢動,中的各項產品都在展位進行了實地演示,現場工程師的詳盡講解及與觀眾間的信息交流都使大家益非淺。
  13. This tester is used to determine the isolation character of the shoe material

    本機在測試鞋底或絕緣鞋材所能承值,以?解其程度。
  14. Power frequency dry resisting voltage : 42 95

    工頻干耐受電壓kv 42 95
  15. Power frequency wet resisting voltage : 34 80

    工頻濕耐受電壓kv 34 80
  16. Power frequency dry resisting voltage : 42 50

    工頻干耐受電壓kv 42 50
  17. Test of rated impulse withstand voltage

    額定沖擊耐受電壓試驗
  18. Rated power frequency withstand voltage one minute dry test wet test phasing to ground 95 85

    額定工頻耐受電壓1min kv對地干試濕試95 85
  19. Rated power frequency withstand voltage one minute vacuum break isolation break 95 110kv

    額定工頻耐受電壓1min kv真空斷口隔離斷口95 110
  20. Rated lighting impulse withstand voltage vacuum break, phase to ground isolation break 185 215

    額定雷沖擊耐受電壓真空斷口對地隔離斷口kv 185 215
分享友人