設計溫度上升 的英文怎麼說

中文拼音 [shèwēnshàngshēng]
設計溫度上升 英文
design temperature rise
  • : Ⅰ動詞1 (設立; 布置) set up; establish; found 2 (籌劃) work out : 設計陷害 plot a frame up; fr...
  • : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
  • : Ⅰ形容詞(不冷不熱) warm; lukewarm; hot; gentle; mild Ⅱ名詞1 (溫度) temperature 2 (瘟) acute ...
  • : 度動詞[書面語] (推測; 估計) surmise; estimate
  • : 上名詞[語言學] (指上聲) falling-rising tone
  • : Ⅰ動詞1 (由低往高移動) rise; hoist; go up; ascend 2 (等級提高) promote Ⅱ量詞1 (容量單位) lit...
  • 設計 : devise; project; plan; design; excogitation; layout; layout work; styling
  • 溫度 : [物理學] temperature
  1. Borrowing ideas from design theory and structure type of oil hydraulic proportional throttle valve and taking domestic and overseas correlative development as reference, this paper determines working conditions of the valve, designs its structure, selects suitable materials of its components, and performs corresponding intensity and temperature check

    在借鑒油壓比例節流閥的理論、結構型式以及參考國內外相關研究成果的基礎,確定了水壓比例節流閥的工作條件,了水壓比例節流閥的結構型式,選取了合適的元件材料,並進行了相應的強校核。
  2. Setup functions enable user - defined adaptation of a wide variety of options such as display contrast, record printout, saving data on the computer, general code, temperature calibration, acoustic signal, date and time, id, data transfer, update fix programs, language, c f changeover, check program, battery change, diagnosis data, printing programs, seal test, service functions for maintenance

    置功能允許使用人員對多種選項進行定義和調節,例如顯示屏幕對比列印記錄把數據記錄到算機總碼校正音響信號日期和時間識別傳輸數據固定程序級語言攝氏和華氏轉換檢查程序更換電池診斷數據列印程序測試密封保養用服務功能。
  3. Setup functions enable user - defined adaptation of a wide variety of options such as display contrast, record printout, saving data on the computer, general code, temperature calibration, acoustic signal, date and time, id, data transfer, update fix programs, language, screen saver, c f changeover, check programme, battery change, diagnosis data, printing programs, seal test, service functions for maintenance

    置功能允許使用人員對多種選項進行定義和調節,例如顯示屏幕對比列印記錄把數據記錄到算機總碼校正音響信號日期和時間識別傳輸數據固定程序級語言屏幕保護攝氏和華氏轉換檢查程序更換電池診斷數據列印程序測試密封保養用服務功能
  4. In the last part, an experiential formula for nondimensional thermal stratification height is obtained, which includes inlet temperature t, inlet velocity v, heat transfer of the wall body q and the distance of heat source l. in order to obtain a more realistic result, the ? model is used to simulate the airflow and the buoyancy item is treated by boussinesq hypothesis. the paper investigates the flow field of the displacement ventilation in an office by a numerical method

    兩方程湍流模型為基礎的壁面函數處理方法,對熱浮力項採用了boussinesq假,得到了收斂的場、速場分佈。在此基礎,給出了熱力分層高算方法,並分析了送風、送風速、圍護結構傳熱和熱源分佈等因素對熱力分層高的影響。
  5. There are many advantages to heat by air condition system, but there are also many problems. the air distribution of air condition room is often designed according to the summer outdoor parameters. thus, in winter, the hot air will arise with the influence of buoyancy, which result in the decline of vertical temperature gradient and produce a successive of problems

    空調送風供暖有著很多的優點,但也出現了很多問題,由於空調房間的氣流組織一般是以夏季工況為工況,在冬季由於送風熱氣流在浮力作用下,引起垂直的增加,並產生一系列的問題,致使空調房間冬季室內熱舒適性較差、能源利用效率較低。
  6. Thaw settlement cause negative friction. this paper base on the thought of " initiative cooling ", aim at three problems existing in common concrete pile used in frozen soil, a new type of pile is proposed to overcome the disadvantages of the classical pile used in frozen soil. pile body within active layer is fluted and refilled with porous materials such as gravels and ballasts, convection will be occur and then thermal exchange inside porous material in winter while only heat conduction exists in summer, as a result the soil around flutings will be cooled, so the top line of permafrost will be drive up

    本文基於「主動冷卻」地基的思想,以及針對凍土地區普通混凝土樁存在的三大問題,提出了一種新型樁的思路,運用數值模擬試驗手段對其冷卻機理與加固機理進行了系統研究,即在凍融活動層的深范圍內,在混凝土樁身的表面刻槽,修築完時槽內填充碎石、塊石等多孔介質,通過外界大氣的自然波動下多孔介質在冬季時存在的對流換熱機制,而在夏季只存在熱傳導,來達到主動冷卻樁周凍土和抬凍土限的目的。
  7. This paper, in allusion to damage of expansion joint of bridge, introduces a sort of new structure of jointless device - semi - integral abutment jointless bridge, and establishes model of general structure finite element of this bridge, and in details analyses its qualities of stress. the model considers the interaction of superstructure - substructure - soil. resistance of the soil behind abutment adopts still soil pressure and elastic resistance when the temperature rising, but active soil pressure when dropping. analysis of qualities stress of bridge includes of action of dead load, car load, temperature load of season character. taking an 100m length pc semi - integral abutment jointless bridge as instance, the paper establishes the model of plane frame by applying large common software - anasys, and analyses it by elastane and large deformation to imitate character of stress and deformation of general bridge. at the same time corresponding models of finite element of joint bridge and integral abutment bridge are established, and unique stress and performance of structure of semi - integral abutment jointless bridge are researched by comparing and analysing character of three different models under same loading, and controlling factor of design and constitution are generalized. in conclusion, for semi - integral abutment jointless bridge, on one hand shear, moment and deflection of the main beam and axis force of substructure are approximate with that of joint bridge, and integral stifmess of structure is increased and damage of expansion joint is eliminated, on the other hand there is axis force in main beam, shear and moment of substructure are bigger than that of joint bridge. in all this type of jointless bridge has rational stress and is worth of application and popularization

    半整體式橋臺無縫橋梁算模型考慮了部結構-下部結構-土的共同作用;臺後土抗力時採用靜止土壓力加彈性土抗力,降時採用主動土壓力;分析橋梁受力性能時考慮了結構自重、車輛荷載和季節性變荷載的作用。以一座橋長100mpc半整體式橋臺無縫橋梁為實例,採用大型通用軟體ansys建立平面框架模型,進行彈性、大變形分析,模擬全橋受力和變形特點;同時建立與此對應的有伸縮縫橋梁和整體式橋臺無縫橋梁有限元模型,通過三種橋型同步加載對比分析,研究半整體式橋臺無縫橋梁獨特的受力特點和結構性能,總結其控制因素和構造要求。通過本文研究知:半整體式橋臺無縫橋梁主梁的剪力、彎矩、撓和下部結構的軸力與梁式橋相近,結構整體剛增大,併除去了伸縮縫病害;但主梁增加了軸力,下部結構剪力、彎矩較梁式橋大;綜合分析是一種受力合理有實踐和推廣價值的橋型。
  8. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停電時間都占據總量60以。因此,及時了解斷路器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合閘線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路電流分斷次數,算每次分閘對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷路器殼體和斷路器周圍空氣結合斷路器熱阻來算斷路器主觸頭穩態的方法,並根據此時的負荷電流間接算主觸頭迴路的電阻;在硬體電路,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給帶來的特殊問題;在通信模塊的中,解決了不同工作電壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  9. Based on the daily surface air temperature data from 200 stations and daily precipitation data th from 739 stations during the second half of the 20 century, schemes for analyzing climate extremes were designed mainly according to percentiles of a non - parametric distribution and the gross errors in the daily data were removed based on a newly designed quality control procedure. the spatial and temporal characteristics of change of climate extremes over china were studied, the major conclusions are summarized as : th 1. slight decrease trends were found for the 95 percentiles of daily maximum temperatures during summer, but larger increase trends were revealed for the 5th percentiles of daily minimum temperatures during winter, especially in northern china

    本文利用中國20世紀後半葉較為完整的逐日和降水觀測資料,了嚴格的資料質量控制方法,以統的邊緣分佈的客觀定義為主要依據,確定了極端和降水事件,研究揭示了近50年中國極端氣候事件變化的規律,得到以下主要結果: 1 .全國最高的極端高值略趨下降;最低的極端低值趨勢顯著,這種增在冬季、在北方最顯著。
  10. Increasing scale of integration and consumption of power has led to the significant increase in power densities encountered in modern electronic equipment. if we do not pay attention to the thermal management of electronic equipment, the large amount of heat generated by the electronic device would not be under the control. especially in some atrocious surroundings, some devices " working temperature would exceed the rated temperature limit and lead to deteriorate the system stabilization or even make the hole system disabled

    現代電子備的集成不斷提高、功耗不斷加大,使得熱流密急劇,如果我們在階段不注重電子備的散熱,那麼元件所產生的熱流將得不到有效控制,特別是在工作環境比較惡劣或電子備比較復雜的情況下某些元件的工作就有可能到導致整個電子系統的工作不穩定乃至失效。
  11. This paper develops the models of evaporation of water and moisture transfer by considering the water moving, whereby the calculation of temperature field is amended with high accuracy

    本文嘗試在一定假條件的基礎建立簡單的水分蒸發遷移模型來考慮水分時混凝土板過程及分佈的影響,進而時場進行適當修正。
分享友人