過冷卻器 的英文怎麼說

中文拼音 [guòlěngquè]
過冷卻器 英文
subcooler
  • : 過Ⅰ動詞[口語] (超越) go beyond the limit; undue; excessiveⅡ名詞(姓氏) a surname
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : Ⅰ動詞1 (後退) step back 2 (使退卻) drive back; repulse 3 (推辭; 拒絕) decline; refuse; reje...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. Its current products include : top oscillation electrical precipitator, side electrical oscillation precipitator, magnetism controlled static electricity precipitator, wet electrical precipitator, honeycomb electric catching tar instrument, high - pressur silicon rectifier equipment and plc low - pressure controlling system, blast furnace gas impulse precipitator, high concentration pulverized coal collector, coke oven and boiler flue gas low pressure impulse precipitator, blower fan inhaler, crossing piping gas cooler, high temperature fume cooler, gyre - orientation impulse hop - pocker and all sorts of molded sections

    目前主要產品有:頂部振打臥式電除塵、側部振打電除塵、磁控靜電除塵、濕式電除塵、蜂窩電捕焦油、高壓硅整流裝置及plc低壓控制系統、高爐煤氣脈沖除塵、高濃度煤粉收集、焦爐及鍋爐煙氣用低壓脈沖除塵、風機空氣、橫管式煤氣、高溫煙氣、回轉定位脈沖大布袋及加工各種彎型鋼。
  2. The calculation method using in factory has larger error and is n ' t used in high ignition point oil transformer. in this paper a calculation method, which has been verified by experiment results, is presented based on the fundamental theories and rule equation of heat transfer to calculate the temperature rise of average oil, top oil, coil, core and hot - point. a program has been compiled

    本課題立足於工程實際應用,根據傳熱學基本原理和經典試驗換熱準則式,通對變壓發熱原理進行分析和研究,提出了一套計算變壓平均油溫升、頂油溫升、繞組溫升、鐵芯溫升和最熱點溫升的計算方法並編制了計算軟體,對影響變壓溫升的因素進行了分析。
  3. 4. the temperature of infall cooling water is less than 30, the velocity of cooling water flow should be over 4l min for capacitor below 1000kvar and it should be over 6l min for capacitor over 1000 kvar

    4 .水的進水溫度不超30 ,水的流速對1000kvar及以下的電容不低於4l min ,對1000kvar以上的電容不低於6l min 。
  4. Cooling coils are introduced into the regenerator to control the temperature and remove the excess heat.

    在再生中放進盤管能控制溫度,也能除去多的熱量。
  5. Two completely different schemes for cooling water flow are obtained by changing the diesel engine ' s water flow from the oil condenser to the water jacket of the cylinder block

    摘要通改變柴油機從機油流入機體水套的水流動方式,得到兩種完全不同的水流動方案。
  6. The flexible wedges must be properly designed to resist the excessive piping forces during the cool down operation when the cooler body squeezes against the hitter wedge

    柔性楔板的設計必須恰當,使之在擠壓鉚釘楔板時,能夠承受住環境程中管道的度壓力。
  7. Analysis is made on structure characteristics of the finned - tube, and analysis has been made on the special heat and mass transfer principle of every micro - unit under both dry and wet conditions. appropriate hypothesis is made and based on the energy, mass and momentum equivalent, the evaporator models of dynamic distributed parameters are set up. in addition, the gascooler and internal exchanger models of dynamic and distributed parameters, the throttling valve models and the compressor models are set up, too

    本文的內容如下: 1對翅片管蒸發的結構特點進行分析,選取適當的微元體,對于干、濕工況下每個微元分別進行傳熱傳質分析,通適當的假設,利用質量守恆方程、能量守恆方程和動量守恆方程建立了蒸發的分佈參數數學模型;對回熱劃分微元建立了分佈參數數學模型;對氣體建立了分佈參數數學模型;對壓縮機建立了數學模型;建立了節流閥的數學模型,為系統模擬奠定了基礎。
  8. For the existing transformer cooling control system has many shortcomings such as the complicated system control circuit, the low reliability, the protection methods of blower fan being so simple, large control error, high fault rate, massive maintenance work and no method to realize telecommunication, this thesis develops a novel intelligent power transformer air - cooled control system based on the center of microprocessor through all - round technology analysis and research

    本文針對變壓系統使用常規控制系統存在的系統控制迴路復雜、可靠性低、風機的保護方式簡單而無法進行故障預測、主變壓油溫測量精度低造成控制誤差大、故障率高、維護工作量大、無法實現遠程通訊等問題,經多方面的技術分析和調研,設計開發了新型的以微處理為核心的智能式電力變壓控制系統。
  9. At hot end of beat pipe, several measures were taken to eliminate heat, namely ( 1 ) traditional sensible heat elimination ; ( 2 ) exhaust air is processed by air washer, then passes through hot end ; ( 3 ) exhaust air is handled by wet film, then passes through hot end ; ( 4 ) sprays water at the top of hot end, respectively

    第一級採用熱管式間接蒸發,熱端布置4種散熱方式: ( 1 )傳統類型的顯熱散熱; ( 2 )排風經噴水室降溫后進入熱端; ( 3 )排風經填料式直接蒸發降溫后進入熱端; ( 4 )直接在熱端頂部淋水。
  10. This paper described a cross - flow type of indirect evaporative cooler with condensation in primary airflow. according to the heat and mass transfer performance of indirect evaporative cooler, three - dimensional mathematical model had been established. with the preprocessor gambit, the geometry and mesh generation was completed

    論文根據間接蒸發程傳熱傳質的特點,對間接蒸發進行了合理必要的簡化假設,應用計算流體力學( cfd )方法,建立了板式間接蒸發的三維數學物理模型。
  11. Choice of the water temperatures entering and leaving the supercooler in the dynamicice - making by supercooling system

    水連續製冰系統中過冷卻器進出口水溫的選擇
  12. This system equips material movement transducer on feeding equipment ; meanwhile, it measures main current of double disk cooler ; the former inputs plc switching value ; the latter inputs analog quantity to judge material condition of double disk for avoiding no material or few material but much water feeding

    該系統在加料設備上加裝自行研製的物料移動傳感,同時檢測雙盤的主電機電流,前者輸入plc開關量採集模塊,後者輸入plc的模擬量採集模塊,用以判斷雙盤內的物料存留情況,避免無料或料少時水的分加入。
  13. The suitable oil flux during the circulating of transformer could be defined according to the difference of temperature between the oil and wind in the inlet and the cooling capacity of the wind cooling system ; besides the oil flux can be determined by ultrasonic, it can be estimated whether the oil is flowing equably by determining the oil flux in the branch pipes ; reducing the oil flux of the oil pump could be realized by controlling to change its frequency, which could not only save the energy, reduce the wastage, but benefit the transformer ' s circulating safely

    變壓運行中可根據進口油溫和進口風溫之差、風容量來確定合適的油流量;油流量可以通超聲波法進行測量,測量油的分管流量還可判斷油流的均勻情況;降低潛油泵流量可通潛油泵的變頻控制來實現,不僅節能降耗,對變壓的安全運行也有著重要意義。
  14. The factory is equipped with large - scale modern machines to process fresh milk, which is collected at the amount of 16, 000 litres a day from the farms in the neighbourhood. the milk goes through an elaborate process cooling, pressing and finally properly preserved. highly sophisticated methods are used to control the temperature, procedural consistency, colour and flavour during the manufacturing of the cheese

    工廠沒有大型的機械,每日自附近農場收集1萬6000升牛奶,經巨型的壓縮等各種步驟,收藏在儲藏室,又用精細的製作方法調以色味熱度密度,再加上當地特有的酒香料和藥草,構成「亞本塞爾」乳酪瑞士三大名牌的乳酪之一。
  15. We need those pumps that are used for water circulation in air coolers. by passing air from wetted straws, this cooler moisturizes the air and cools the room

    我們需要讓水在空氣中循環的那種水泵。通抽濕管使空氣流通后,就可以使空氣變濕潤,從面降低室溫。
  16. The authors first apply basic theory of equivalent heat drop on the common circulation heat calculating model for thermal system in supercritical pressure power unit with second reheat cycles and other kind of condensing steam turbine by mathematical derivation strictly, based on the normal energy balance and theory of equivalent heat drop, aiming at characteristics of thermal system in which there are outer steam coolers that high pressure heater and low pressure heater carry

    摘要以常規熱平衡方法和等效熱降理論為基礎,針對二次再熱超臨界機組熱力系統高低壓加熱均設置外置式蒸汽的特點,經嚴格的數學推導,將等效熱降理論應用於二次再熱超臨界機組熱力系統循環吸熱量計算的研究,並提出了適用於不同類型凝汽式機組的通用數學計算模型。
  17. This paper introduces the principle and method of forced - air cooling system of transformer controlled by dsp, according to the season and load of transformer, the designed system can automatically accomplish frequency conversion and the cooling device ' s devotion by fuzzy - neural network controller

    摘要介紹了以dsp作為核心控制件的大型變壓控制系統的原理和實現方法,根據變壓負荷、季節等變化,通模糊神經網路調節自動投切組數以及是否進行變頻運行。
  18. Compressed gas cooler can go to separator via a manual line up for start up purpose

    壓縮氣在開工時可通手動線連至分離
  19. Production of residential and commercial air conditioning, refrigeration compressors and condensing units

    -主營壓縮機乾燥儲氣罐及成套設備。
  20. Heat exchangers - test procedures for establishing the performance of forced convection unit air coolers for refrigeration

    熱交換.製用強制對流元件空氣的性能確定試驗
分享友人