過渡電容 的英文怎麼說
中文拼音 [guòdùdiànróng]
過渡電容
英文
transition capacitance- 過 : 過Ⅰ動詞[口語] (超越) go beyond the limit; undue; excessiveⅡ名詞(姓氏) a surname
- 渡 : Ⅰ動詞1 (由此岸到彼岸;通過) cross (a river the sea etc ) 2 (渡過) tide over; pull through 3 ...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 過渡 : transition; transit
- 電容 : electric capacity; capacitance; capacity
-
Due to the vibration and swing of generating units of wujiangdu hydropower station are larger than specifications when its capacity is added, the authors analysis the reasons and provide the measure of weight correction
摘要針對烏江渡水電站增容改造后1號機組振動擺度偏大的現象,分析了引起機組振動擺度過大的原因,並提出了配重校正的措施。Then, in the period of chinese telecom regulation shifting from monopoly to competitive, the task, principles of opening telecom market and content of telecom regulation had been analyzed
然後對我國電信管制由壟斷走向競爭過渡期內的任務,電信業務市場開放的原則及電信市場管制的內容進行了分析。Its accuracy can not be affected by coupled inductance, fault resistance, distributed capacitance and asynchronous angle
該測距方法在原理上不受線間互感、過渡電阻、分佈電容、不同步角的影響。By means of resistance and capacitance coupled negative feedback method to control the plasma discharge development process and prevent the transition from glow discharge to spark discharge in a pin - to - plate static air plasma generator, a stable alternative current atmospheric glow discharge is produced successfully
在靜態大氣壓空氣針板等離子體發生器中,採用阻容耦合負反饋方法控制等離子體放電發展過程,成功地抑制了輝光放電向火花放電的過渡,產生了穩定的交流輝光放電。A composite electrode material comprising carbon nanotube and transition metal oxide may meet both the powerand the energy requirements. the properties of supercapacitor utilizing carbon nanotube as electrode material are studied
通過充分利用其較大的比表面積和適宜的孔徑,可望得到大容量、高功率的超級電容器,與過渡金屬氧化物復合更能提高其綜合性能。Results of analysis indicate the self - charge ability of active vsi power filters without additional equipment under start - up process and their ability of maintaining the average voltage on dc capacitor in steady state
分析結果表明,無需附加任何充電環節或裝置,電壓逆變器型有源電力濾波器就能自動完成對儲能電容器的初始充電過程,然後自動過渡到穩定工作狀態,並在穩態中維持儲能電容器上的電壓平均值不變。The transient analysis and simulation studies in time - domain showed that the transient capacitance current of busbar is unable to be caught due to the limitation of the given sampling frequency, therefore the transient current singularity of the fault line and the non - fault line will approximate, which prevents to identify the fault line with the criterion calculation result of transient current protection
研究結果表明,線路出口故障時暫態電流保護完全失去選擇性的根本原因是,在給定的采樣頻率的限制下,難以捕捉到過渡過程中極其短暫的母線分佈電容中的暫態電流,從而故障線路與非故障線路暫態電流波形的奇異性相近,根據故障線路和非故障線路的暫態保護判據計算結果不能正確識別故障線路。分享友人