采果器 的英文怎麼說

中文拼音 [cǎiguǒ]
采果器 英文
fruit picker
  • : 采名詞(采地) feudal estate
  • : Ⅰ名詞1 (果子) fruit 2 (事情的結局; 結果) result ; consequence 3 (姓氏) a surname Ⅱ動詞(吃...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. In digital relay, the percentage of noise will increase rapidly with the increase of sampling rate when derivation calculus is substituted by sampled difference term. to solve this problem, a new method using fragment function integrated with the least square algorithm is proposed in this paper. the influence of white noise is greatly reduced and the accuracy of the dead angle calculation is nicely improved after adopting the new method

    在數字式保護中,如用差分代替求導將導致噪聲的百分比誤差隨著樣頻率的提高而劇增,本文對此進行了分析並提出了用分段樣條函數最小二乘法來計算電流波形的導數值,以便在提高樣率的同時降低噪聲誤差的影響,並將其應用於基於32位浮點dsp的新型變壓保護裝置。
  2. This experiment to adopt the method that paraffin was cut into slices studied the structural growth process on appearance and dissect of pugionium cornutum ( l ) gaertn in germination period and young sprout ; and to adapt wild flower, fruit, seed and cultivated root, stem and leaf of pugionium cornutum ( l. ) gaertn in leaf lushing period and leaf exhausting period from eerduosi city proceeded the research on appearance and anatomies. the result enunciates : the organs of pugiorium cornutum ( l. ) gaertn in root, stem and leaf have started dividing in germination period ; the transporting tissue and storing water tissue in young sprout period has been divided ; the ransporting tissue is flourishing, but the supporting tissue is unflourishing, so the root, stem and leaf of pugionium cormutum ( l ) gaertn is suitable for edibility

    本試驗採用石蠟切片研究了沙芥發芽期、幼苗生長期各官形態及解剖結構的變化過程;並對自鄂爾多斯市野生沙芥花、實、種子及人工栽培的葉片旺盛生長期、葉片生長衰退期的根、莖、葉等材料進行了形態及解剖學研究,結表明:沙芥發芽期根、莖、葉各官內組織已開始分化;幼苗期已分化出發達的輸導組織及貯水組織;葉片旺盛生長期各官具有發達的輸導組織,但機械組織不發達,因此沙芥的根莖葉適于食用。
  3. In this paper, the operation theory is ntroduced. we research the quasi. synchronous alternative sampling echnology in detail to improve the precision of the instrument and discuss some problem about the plication of this method. we introduce the develop of hardware and software in the whole instrument. at last, we sive out the result of experiment and the analyses of error

    文中論述了該電參數測量儀的工作原理,著重研究了提高測量精度的準同步樣演算法,並討論了該演算法在單片機中應用的幾個實際問題。在此基礎上,詳細介紹了整個儀的軟硬體開發過程。最後對儀進行了實驗和誤差分析,給出了實驗結和誤差分析結
  4. This paper starts the research of the liquid floated pendulous accelerometer testing system according to the engineering. at first, this paper gives the brief introduction of the history and present status of accelerometer and its testing technology, the working principium and math model of the liquid floated pendu - lous accelerometer, and then, decides the binary width pulse force retrim loop as the design proposal of testing system, researches the transfer function of every part in the system emphasizly, analyses the stability of the whole accelerometer testing system from the angle of control theoretics by the open loop transfer function of system, and designed the correcting net, analyses the basal problems such as resolution, sampling restraint, precision and so on, designs the hardware testing circuits such as preamplification, band - pass filter, alternating amplifier, phase sensitive demodulatorn, pulse - width modulation, frequency scale circuit, moment current generator. finally, using the graphics program language labv - iew which is designed for testing field especially by ni accomplishes the solfware design of testing system, realized the testing functions

    首先對加速度計及其測試技術的發展歷史和現狀,液浮擺式加速度計的工作原理和數學模型等作了簡要的介紹,然後確定了以二元調寬脈沖再平衡測試迴路為設計方案,並從控制理論的角度進行了分析,著重研究了系統中各部分的傳遞函數,利用系統開環傳遞函數分析了系統的穩定性,同時設計了系統的校正網路;分析了二元調寬脈沖再平衡測試迴路的解析度、樣約束以及測試精度等基本問題,並按照系統分析的結設計了包括前置放大、帶通濾波、交流放大、相敏解調、脈寬調制、頻標電路以及力矩電流發生等測試系統各部分硬體電路,驗證了電路的正確性,最後按照測試系統的要求,採用了美國ni公司專為測試領域所開發的虛擬儀工具? ? labview作為測試軟體開發工具,利用該圖形化編程語言完成了測試系統軟體部分的設計,實現了測試功能。
  5. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的電流差動保護無論對於何種形式的輸電線路都是一種簡單、可靠、選擇性強的保護形式,電力系統的發展使得電流差動保護應用於線路保護成為需要,而電子、通信技術的發展使得電流差動保護應用於輸電線路成為可能。首先,本文對目前線路保護的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量電流差動保護易受正常負荷電流和故障過渡電阻影響的缺點,同時為加快差動保護的動作速度,對基於故障分量瞬時樣值電流差動保護的原理、判據、動作特性等作了討論和分析,結表明基於故障分量瞬時樣值電流差動保護在可靠性、靈敏度、抗電流互感飽和方面明顯優于常規相量電流差動保護,對電流差動保護各端的同步樣方法和數據通信也進行了分析和評價。
  6. Divider, coaxial line, trigger, signal processing, data acquisition, acquisition control and waveform analysis software is included in the device. when the device operate in the system, overvoltage is transferred to coaxial line by the divider. if the overvoltage amplitude is higher than initialization value, data acqusition card start sampling. when sampling is over, computer save data to file. engineer can analyse parameter of waveform by appropriative software reading data from file

    當裝置在線運行時,系統中出現的過電壓信號通過分壓傳遞到同軸電纜,通過觸發電路判斷,如大於預先設定的值則啟動採集卡的同時樣,樣結束后,計算機把數據存盤並以文件格式保存,管理人員隨時通過調用專用軟體調取文件進行各種參數分析。
  7. Overvoltage amplitude is higher than initialization value, data acqusition card start sampling. when sampling is over, computer save data to file. engineer can analyse parameter of waveform by appropriative software reading data from file. in the trial measurement, the device shows good performance. simulant trial and actual result indicate that method in the paper acquire approving effect, and the device can be used in the lokv distribution network

    當裝置在線運行時,系統中出現的過電壓信號通過分壓傳遞到同軸電纜,通過觸發電路判斷,如大於預先設定的值則啟動採集卡的同時樣,樣結束后,計算機把數據存盤並以文件格式保存,管理人員隨時通過調用專用軟體調取文件進行各種參數分析。
  8. If you or your friends are exercise equipment manufacturer, please contact me for business opportunity. i am currently sourcing for yoga ball, steps, and 38 " trampoline

    您或您的朋友是健身材製造商,麻煩與我聯絡。現在需要購揄珈用健身球,有氧體操用的踏板,和38 "彈簧跳床。急!謝謝!
  9. Later, we interviewed the person who developed the machine in order to obtain a more scientific view on these results and interpretations

    后來,為了對這測試的結和分析取得更多的科學論證,我們訪了開發這儀的人。
  10. In this dissertation, we studied the tcra1101plus total station position system, which introduced the principle and characters of the instrument ' s closed loop tracking system. also we explained the cause of prism ' s position error and brought forward mathematic model to correct, moreover, the good results has been drawn form the expenriments. the kinetic survey system have been realized, which the sampling rate attain more than 5hz and the position precision can be less than 2mm on condition that targeted - point moving slowly at the velocity below 2cm / s. having finished the survey system to examine whether the fine - tuning stewart platform in good status, we have finished mensurating the position reference of the fine - tuning stewart platform and the offset of the prism

    在此基礎上研製了多臺儀在線控制高頻樣動態跟蹤測量系統,樣率大於5hz ,在跟蹤小於2cm / s低速運動目標時,測量精度好於2mm ;完成對饋源二次精調系統的檢測,包括對二次精調平臺位置基準的標定和觀測棱鏡偏心差的測定;設計不同動態測量實驗,對全站儀動態跟蹤的誤差來源和特點進行了分析;從實驗角度,對全站儀的測量時滯及其穩定性進行了測試分析,給出了定量的結;比較了全站儀和計算機的內部時間系統,發現兩者存在較大差異。
  11. In this paper, a new control strategy based on the adaptive deadbeat voltage space vector is presented. this control scheme has a lower sample frequency and a smaller difference between switch frequency and sample frequency. it has many advantages, such as producing zero vectors organically, tracing exactly, non - shaking, etc. and its dynamic response is better

    對于電能質量調節來講, pwm跟隨指令參考信號的控制性能在很大程度上影響著裝置的補償效,本文選擇無差拍電壓空間矢量控制為系統控制策略,這種控制方法具有樣頻率低,開關頻率與樣頻率的差距小,能有機地產主零矢量、跟蹤精確以及無抖振等優點,動態響應快。
  12. This paper simulates the effect of voltage fluctuation inspection through the tool of matlab. and proves the filters ' s stability. in the part of self - checkout, pi ( proportional integral ) control arithmetic is put forward to check the gain k and the calculated results show the method ' s effectiveness. then many comparements toward pst are done in different realization methods such as different interpolation points classification number and sample frequency. though simulation and calculation we can see the designed flicermeter can meet our country ' s standands

    文中利用matlab對電壓波動的檢測效進行了模擬;並對涉及到的濾波的穩定性做了證明;在自校驗部分提出了將pi (比例、積分)演算法用於數字濾波增益k值的確定,取得了不錯的效;然後分別從取不同插值點、不同分級數和不同樣頻率這幾個方面出發,對計算出的p _ ( st )值進行了比較。
  13. It should be regarded as a medical accident if the medical institution its careless blood - collection or using unclean medical apparatus damages the sufferer ' s health ; on the contrary, it should not be regarded as a medical accident if the damage is due to the virus contained in the blood collected by the blood - supplying station, not due to the fault made by the medical units

    是由於醫療機構自己血或因醫療機構械不潔造成患者身體損害,則應當視為醫療事故;如是由於供血機構所血液含有病毒,而醫療機構沒有過錯,就不應當視為1醫療事故。
  14. Other than traditionally theory analyze and discussion of digital correlator which is laid after demodulator, a scheme based on non - interrelated correlative dll will be discussed in this paper after referencing the theory and the result of simulation. the demodulated data and the information of carrier are not need in this plan. we sample the result of correlation between local sequences and the received signal, then realizing the code synchronization by software

    不同於一般的理論分析以及解調后數字相關的討論,本文通過理論分析與模擬結,選用了非相干相關同步的基本結構,並加以改進,不需要解調和載波的信息,將本地序列與接受信號直接相關后進行樣,通過軟體的方法,實現同步。
  15. The pulse - peek sampling and adc module is able to catch a single and very narrow pulse in order to sample its peek value without being influenced by other pulses or noise. the pulse - peek sampling and adc module can also adapt itself to different rising edge of pulses, so it can scale different types of explorers made by our research institute

    X射線探測定標分析系統的前端脈沖峰值採集及其轉換電路能夠實現單個快速脈沖的捕捉及對不同脈沖上升沿陡緩的適應,它對不同傳感的放大信號特徵都有很好的適應性,對脈沖峰值樣的結具有很高的精度。
  16. Comparison of different sampling methods for determining dust concentration

    3國不同粉塵測定結的比較
  17. The analysis by sampling data of no. 2 caster bao steel shows that the integrated heat transfer coefficient is independent of the width of slabs, and the effect of superheat is not clear, but the effect of casting speed is very obvious

    摘要對寶鋼2號連鑄機現場數據的樣分析結表明:連鑄坯在線寬度對結晶綜合傳熱系數沒有影響。
  18. The shunt active power filter which uses the i p ? iqmethod and the hysteresis - based current control strategy has been simulated, and analyze the inductor and the cut - off frequency which affect the performance of shunt active power filters

    Iq諧波電流檢測和電流滯環跟蹤控制技術的並聯型有源電力濾波進行了模擬研究,重點分析了影響有源電力濾波補償效的濾波電感和樣電路截止頻率。
  19. It was found that, for chosen bioaerosol generation parameters and weather conditions, the new personal sampler would be capable to reliably detect pathogens at all locations occupied by crowd, even at distances of up to 600 m from the source

    發現,以選定的生物氣膠產生參數及氣候條件,此新個人能在群眾聚集的所有位置,可被信賴地偵測出致病菌,甚至距發生源達600公尺遠亦可。
  20. Impact of sampling time on sampling effect of

    樣效的影響
分享友人