電力輸送故障 的英文怎麼說

中文拼音 [diànshūsòngzhàng]
電力輸送故障 英文
power transmission failure
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ名1 (力量; 能力) power; strength; ability; capacity 2 [物理學] (改變物體運動狀態的作用) forc...
  • : Ⅰ動詞1 (運輸; 運送) transport; convey 2 [書面語] (捐獻) contribute money; donate 3 (失敗) l...
  • : 動詞1 (運送; 傳送) deliver; carry 2 (贈送) give as a present; give 3 (伴送; 送別) see sb of...
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • 電力 : [電學] power; electric power電力變阻器 power rheostat; 電力捕魚 electrofishing; 電力潮流 directio...
  • 輸送 : deliver; supply; carry; transport; convey; feed; transmit; transfer; transportation; delivery
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  1. In the paper, the transmission power of section constituted by the assigned branch is seen as objective function, assigning the adjustable generators both in sending system and receiving system, assigning the faults set, including the constraint conditions such as the differences between the angles of rotor and the inertia center angel of the whole system, the thermal stability of branch and node voltage, obtaining the results by using interior - point solution and line - predominant jordan

    本文提出的考慮暫態穩定約束的可用演算法是以指定線路組成的斷面的傳功率為目標函數,指定端系統和受端系統中參考調節的發機,指定集情況下,以發機轉子相對全系統慣性中心的角度差、線路熱穩定、節點壓等構成約束條件,採用內點法和行主元約當逐行消去法求解問題的最優解。
  2. In high voltage power transmission line, in order to ensure power system juxtaposition operation ' stability and bump feeding power up against, at a great many instance, without delay from line ' s terminal excision by the protected line interior fault

    在高壓線路上,為了保證系統並列運行的穩定性和提高功率,在很多情況下都要求無延時地從線路兩端切除被保護線路內部的
  3. Here, both electric current protection and distance protection neither be able to satisfaction require, whereas none but pilot protection could realize complete line rapid trip off, the stability and bump feeding power, reduce fault bring about " spoil degree, improvement cooperateing performance with backup protection

    此時,流保護和距離保護都不能滿足要求,而只有縱聯保護可以實現全線速動,因此它可保證系統並列運行的穩定性和提高功率、縮小造成的損壞程度、改善與后備保護的配合性能。
  4. A pressure transducer was set up in this system to realize pressure control in main lines and adjustment of pump operating time ; the distributors were designed to accomplish grease storage in fixed quantity and transport them into all lubricating points ; the single chip microcomputer was utilized to control interval lubrication and realize auto - lubricating or fault alarm

    系統通過設置壓傳感器實現主油路的壓控制和油泵工作時間的自動調節,通過配油器實現定量儲油和將油脂至各潤滑點,通過子監控器設定加脂間隔時間,實現自動加脂與報警。
  5. This thesis presents a single - terminal fault location technique that is used together with recloser. the technique takes advantage of reclosing of single - terminal recloser to eliminate the influence of the remote source impedance. a distributed parameter line model is used for the proposed algorithm, thus the technique can be used in hv transmission line

    為了克服這一缺點,本文提出了與自動重合閘配合使用的單端測距方法,根據系統的運行特點,利用線路在試時自動重合閘的單端重合狀態來消除對端系統的影響,測距演算法建立在分佈參數模型基礎上,使其可應用於高壓線路。
分享友人