  1. The preventions of pollution flashover on the external insulation of electric equipment

    力設備外的防污閃措施
  2. Insulation coordination for equipment within low - voltage systems - a comprehensive method for determining clearances and creepage distances equal to or less than 2 mm

    低壓系統內設備的.等於或低於2mm的余隙距離和漏距離的測定法
  3. The main tests and researches are as following : to study the ac flashover characteristic of composite insulator in different icing states by imitating tests in multifunctional artificial climate chamber, and analyze the effect of ice amount and icing water conductivity on flashover voltage, put forward a flashover mechanism by analyzing the icing flashover process. to study the ac flashover characteristic of composite insulator in different altitude and icing states together by imitating tests in multifunctional artificial climate chamber, and mainly analyze the effect of altitude ( air pressure ) and ice amount on flashover voltage, and investigate the flashover mechanism. to investigate the effect of high altitude and icing on the hydrophobicity of composite insulators

    本文主要進行了以下試驗研究: 1 )在多功能人工氣候室里模擬不同覆冰程度下子的交流閃絡特性,主要分析覆冰量和覆冰水導率對閃絡壓的影響,並對其覆冰閃絡過程進行機理分析; 2 )在多功能人工氣候室里模擬不同海拔高度和覆冰程度作用下子的交流閃絡特性,主要分析海拔高度(即氣壓)和覆冰量對閃絡壓的影響,並進行閃絡機理分析; 3 )研究高海拔和覆冰對子憎水性的影響。
  4. Abstract : in this paper, a traditional method for testing missile ' s insulance wa s introduced, and a new way for testing missile ' s insulance by the intelligent t est system of the embedded controller, the relay matrix and the integrated compa rison wa s presented

    文摘:介紹了導彈阻測試的一種傳統方法,提出了採用單片機智能測試系統、運用矩陣思想和比較法測試導彈阻的新方法。
  5. Insulated cables and flexible cords for installations. halogen - free 0, 6 1 kv cables with improved characteristics in the case of fire, type c1, with cross - linked synthetic insulation and with extruded synthetic protective sheath

    設備用纜和軟導線.帶擠壓成材料保護套的網狀c1類改進燃燒性能的無鹵素0 . 6 1千伏
  6. ( 2 ) a new method for on - line forecast and analysis of the insulation safety of large generators is found by combining the topology construct of the electric network in power stations with the electromagnetic relationship inside large generators and using the field - circuit analysis theory

    ( 2 )運用場路分析理論,將廠站氣網路拓撲結構與大型發機組內部磁關系相結,提出了一種用於大型發安全在線預測分析的新方法。
  7. Based on instance of mania project, the article raises an insulation coordination method for high elevation zone and the criterions fulfilling the insulation coordination conditions. it also has calculated the demanding values of withstanding voltage of all voltage levels equipment, and the results of outer insulation coordination. at the mean time, it proves the success of applying " humidity ratio " integrated emendation method in the mania project

    文中又根據滿拉工程實例,提出適高海拔地區使用條件的方法及滿足條件的判據;採用「比濕」校正法計算了滿拉工程各級壓設備耐受壓要求值及外成果,同時也證明「比濕」校正法在滿拉工程應用的成功。
  8. It compares and analyses the equipment test voltage emendated to standard atmosphere conditions with the equipment nominal withstanding voltage. and then it concluded that : the emendation value educed by " humidity ratio " integrated emendation method is basically equal or close to the equipment nominal withstanding voltage ; but the values by two traditional emendation methods are mostly higher. it also proves that, " humidity ratio " integrated emendation method is more perfect than any other methods, and it can reflect the influence degree of atmospheric parameters on electrical equipment outer insulation discharge voltage actually

    文中選擇「比濕」校正法和兩種傳統校正法,分別對西高所為羊八井、拉薩、羊湖110kv變所設備所做的人工氣候室模擬試驗數據及雲南中試所做的zs - 110工頻放壓試驗數據進行校正計算,將試驗壓的校正值與試驗設備的標稱耐受壓水平進行比較分析;認為: 「比濕」校正法的校正值與設備耐受壓水平基本相等或接近,而兩傳統校正法的校正值大多高於設備耐受壓水平;進一步證明, 「比濕」校正法是目前諸多校正法中較為完善的,能真實地反映大氣參數對氣設備外壓的影響程度的校正法,在高海拔力工程設計中應推廣應用。
  9. 10. 02 test methods for complex permittivity dielectric constant of solid electrical insulating materials at microwave frequencies and temperature to 1, 650 c

    微波頻率和溫度為1650時實心材料常數測試驗方法
  10. Utilities spends significant amounts of money on insulator washing and cleaning before the restoration of the service. laboratory studies and industrial experience have shown that both contamination and wetting of insulator surfaces, which initiate the flow of leakage current, are required for insulator flashover. the leakage current leading to flashover has distinctive stages of development

    人們在詳盡的理論分析和大量的高壓實驗后,發現子泄漏流的變化與其污穢及受潮程度有著密切的關系,反映了污閃的發生過程,因此泄漏流檢測是診斷線路子早期故障的一種有效手段。
  11. In accordance with the technological difficulties encountered in the process of insulation supervision based on the dissolved gases analysis ( dga ), several kinds of model and method are presented to improve the reliability and precision of fault diagnosis of the power transformer. main research content includes : by deeply studying the common transformer faults diagnosing methods, such as three - ratio methods and improved electrical committee agreements, several shortcomings such as uncertainness judgment when the fault reasons, phenomenon and principles come out together while can not consistent to each other etc. for this reason, the old methods can not fully meet the need to engineering practical application. considering fuzzy relationship matrix can fully represents the causality between fault symptoms and fault types, when diagnosing complex equipments with multiple symptoms and fault causes such as power transformer, a synthetic fuzzy diagnosing model is firstly proposed to diagnose transformer ' s insulation faults based on dga in this paper

    本文針對應用油中溶解氣體分析方法進行變壓器監督時所遇到的主要技術難點,提出了提高變壓器故障診斷的準確性、可靠性的幾種模診斷方法,主要研究內容有:通過對判斷變壓器故障常用的三比值法和改良協研法的深入分析,其診斷準確率較高,但對故障原因、故障現象和故障機理間同時存在不確定性和模糊性的變壓器等氣設備的故障診斷,難于滿足工程應用的需要;在處理變壓器等結構復雜設備的多癥狀、多原因故障診斷時,模糊關系矩陣可以全面反映這種癥狀與故障類型間的因果關系,進而提出了變壓器故障診斷的模糊診斷模型;同時作者還深入分析了模糊運算元的特性;針對常用的模糊評判結果的模糊集的集化方法的不足性,提出了將模糊診斷與模糊規則推理結起來進行故障診斷的方法,能達到較好的效果。
  12. Combined mechanical and electrical strength

    強度
  13. Established in 1974, longkou appliance insulating materials factory is one multiple managing factory that produces many kinds of insulating materials

    龍口市材料廠建於1974年,是生產多種材料的製造廠。
  14. Furthermore, the principle of the intelligent test system of 8098 t ype embedded controller was introduced, and the principle of testing missile ' s i nsulance using this system and the realizable method were explained in detail

    分析了逐點比較法與比較法的原理及特點,敘述了採用繼器矩陣來實現阻被測點的選擇與轉換原理,介紹了8098單片機智能測試系統的組成及工作原理,闡述了採用該系統測試導彈阻的原理和實現方法。
  15. Plenty of diagnosis examples demonstrate the validity of the gray relationship analysis method in diagnosing power system insulation faults. not only the misjudgment rate can be reduced, but also the transformer fault incidences can be classified by using self - adapted weight fuzzy clustering method. further more, the transformer insulation condition can be analyzed, as well as the fault position can be located by recognizing the fault types

    經過大量的診斷實例表明:本文的模糊診斷與模糊規則推理結起來的故障診斷方法對力研究變壓器故障診斷是有效的,能大大減少錯判、誤判比率;自適應加權模糊聚類方法能對變壓器的故障樣本正確分類,同時能有效判別故障類型,診斷的準確性大大高於常用的三比值法。
  16. At present insulation - monitoring of power equipments mostly has focused on the single equipment or single monitoring item, and the comprehensive insulation - monitoring system, which can be employed by several equipments and can monitor more monitoring item, has not been developed yet

    力設備在線監測基本上還是局限在單個設備或單個監測量的監測,沒有一個通用的能監測多設備、多特徵量的監測系統。
  17. The research works are shown mainly as follows : 1 ) the actuality and outlook of on - line detecting and fault diagnosis technology of gases dissolved in oil are analysed deeply, and characteristics of insulation structure of power transformer, evaluation of operating reliability and the relationship between ordinary faults inside transformer and gases dissolved in transformer oil are studied too. analysing the purposes of detecting gases dissolved in transformer oil on - line, we can know that primary indexes to evaluate the technology of on - line detecting gases dissolved in transformer oil are reliability of system, accuracy of detected data, validity of diagnosis, automatization and price of systems

    主要研究內容有: 1 )深入分析變壓器油中多種溶解氣體在線監測及故障診斷技術研究現狀及應用前景,研究力變壓器結構特性、運行可靠性評估以及變壓器內部常見故障與油中溶解氣體對應關系,通過對在線監測變壓器油中溶解氣體的目的分析得出系統運行的可靠性、監測數據的正確性、診斷的有效性、系統的自動化程度、系統的價格等是評價變壓器油中溶解氣體在線監測技術的指標。
  18. Insulation coordination for equipment within low - voltage systems - part 5 : a comprehensive method for determining clearances and creepage distances equal to or less than 2 mm

    低壓系統內設備的.第5部分:等於或低於2mm的余隙距離和漏距離的測定法