電纜外徑 的英文怎麼說

中文拼音 [diànwàijìng]
電纜外徑 英文
outside diameter of cable
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ名1. (拴船用的鐵索或多股粗繩) cable; hawser; mooring rope 2. (擰成多股的似纜物) thick rope; cable Ⅱ動詞(用繩索拴船) cable
  • : Ⅰ名詞1 (外面) outside; external side 2 (外國) foreign country 3 (以外) besides; beyond; in ...
  • : Ⅰ名詞1 (狹窄的道路; 小路) footpath; path; track 2 (達到目的的方法) way; means 3 (直徑的簡稱...
  • 電纜 : cable; electric cable
  1. 3. the permitted bending semidiameter is not less than four times of cable outside diameter

    3 .允許彎曲半不小於電纜外徑的4倍
  2. Permissible bending radius : not less than 6 times of overall diameter for unarmored cable ; not less than 12 times of overall diameter for armored or screened cable ; not less than 6 times of overall diameter for screened flexible cable

    推薦允許彎曲半:無鎧裝層應不小於電纜外徑的6倍;有鎧裝層或屏蔽層結構的應不小於電纜外徑的12倍;有屏蔽結構的軟應不小於電纜外徑的6倍。
  3. Permissible min. bending radius : no less than 6 times of the completed cablediameter in case of unarmoured cable ; no less than 12 times of the completed cable diameter in case of armoured or copper tape screened cabel ; no less than 6 times of the completed cable diameter in case of screened flexible cabel

    3的允許彎曲半:無鎧裝層的,應不小於電纜外徑的6倍;有鎧裝層或銅帶屏蔽結構的,應不小於電纜外徑的12倍;有屏蔽層結構的軟,應不小於電纜外徑的6倍。
  4. While installation the ambient temperature should not be lower than 0, and the bending radius radius should not be less than 10 times of outer diameter of cable

    敷設時的環境溫度不低於0 ,最小彎曲半應不小於電纜外徑的10倍。
  5. Minmum thickness of sheath and maximum overall of cable refer to table 3

    終端的護套最小厚度和最大見表2 。
  6. When installing crooked radius aluminium bring or aluminum pipe should smaller than cable 30 times of external diameter, unless it install when not transporting it should handle with care, can t twist, can t not when not piling up heavy pressure, should keep dry, ventilate, not moist while preserving

    安裝時彎曲半鋁帶或鋁管的應不小於電纜外徑的30倍,安裝運輸時應輕拿輕放,不能扭曲,堆放時不能重壓,存放時應保持乾燥、通風、不潮濕。
  7. With the increasing of digital cable transmission frequency, srl ( structural return loss ) on - line evaluation using diameter data of digital cable core became a method of cable quality control. higher measuring precision and higher measuring speed of the diameter gauge was required

    ,由於數字通信傳輸頻帶的提高,對均勻性要求也不斷提高,採用直信息來在線評估數字通信的srl (結構回波損耗)成為也質量控制一種方法,這就對測儀的測試性能提出了更高的要求。
  8. Due to restriction with the array aperture transition time, traditional phased array radar works under relative narrow signal bandwidth, so this restricts the application of phased array radar in the field where high performance is demanded. however, optically controlled phased array radar ( ocpar ) adopts the photoelectron technology, counteracts the aperture transition time via the method of optical true time delay ( ottd ), so it can realize wide instantaneous bandwidth and squint - free operation ; meanwhile, it can realize the miniaturization of phased array radar and has super anti - electromagnetism interference capability

    而光控相控陣雷達採用光子技術,通過光實時延遲的方法來抵消孔渡越時間,可以實現相控陣雷達的寬帶寬角掃描;同時也可以使得相控陣雷達小型化,並具有強的抗磁干擾的能力;另,由於光纖傳輸具有損耗低、頻帶寬等固有優點,採用光纖連接雷達天線和雷達控制中心,可以使兩者的距離較採用同軸有較大的提高,更有利於保護雷達控制中心。
  9. Bending radius : cable with no shielded layer not smaller than 6 times of its outer diameter ; otherwise, not smaller than 12 times

    最小彎曲半:無鎧裝層應不小於電纜外徑的6倍帶鎧裝層應不小於電纜外徑的12倍
  10. A cable consisting of one conductor, usually a small copper tube or wire, within and insulated from another conductor of larger diameter, usually copper tubing or copper braid

    一種,它的中心是一根導體,通常為較細的銅管或銅線,其周圍為絕緣介質,面為直較大的導體,通常為銅管或銅編織物。
  11. The min curving radius : copper tape screened cable and steel tape armored cable should be at least 12 times the outer diameter. other cable should be at least 6 times the outer diameter

    最小彎曲半:銅帶屏蔽、鋼帶鎧裝不小於的12倍,其它不小於電纜外徑的6倍。
  12. Bending radius : cable with no shielded layer not smaller than 10 times of its outer diameter ; otherwise, not smaller than 12 times

    最小彎曲半:非鎧裝不小於電纜外徑的10倍鎧裝不小於電纜外徑的12倍
  13. The bending radius of a three - core cable should not less than 15 times of the cable diameter

    5 、彎曲半:三芯不小於電纜外徑15倍;單芯不小於電纜外徑20倍。
  14. Installation temperature should be not lower than 0, and recommended allowable bending radius should be not less than 12 times of overall diameter of cable

    2的敷設溫度應不低於0 ,推薦的允許彎曲關不小於電纜外徑的12倍。
  15. The bending radius should not less than 15 times of cable diameter

    彎曲半:不小於電纜外徑的15倍。
  16. The bending radius should not be less than 25 times of the cable diameter

    彎曲半:不小於電纜外徑的25倍。
  17. For screened flexible cable, not less than 6 times of cable diameter

    有屏蔽層結構的軟,應不小於電纜外徑的6倍。
  18. Permissive bending radius of cable should be no less than 20 times of external diameter of cable

    3的允許彎曲半不小於電纜外徑的20倍。
  19. Allowed bending radius not smaller than 6 times of its outer diameter, laying temperature not lower than 0

    允許彎曲關應不小於電纜外徑的6倍,敷設溫度應不低於0 。
  20. During installation the min ambient temperature shall be above 0 and the bending radius of cable shall not less than 6 times of its external diameter

    的敷設溫度不低於0 ,推薦的允許彎曲半為不小於電纜外徑的6倍。
分享友人