電解分析儀 的英文怎麼說

中文拼音 [diànjiěfēn]
電解分析儀 英文
electrolytic analyzer
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 解動詞(解送) send under guard
  • : 分Ⅰ名詞1. (成分) component 2. (職責和權利的限度) what is within one's duty or rights Ⅱ同 「份」Ⅲ動詞[書面語] (料想) judge
  • : Ⅰ動詞1. (分開; 散開) divide; separate 2. (分析) analyse; dissect; resolve Ⅱ名詞(姓氏) a surname
  • : 名詞1 (人的外表) appearance; bearing 2 (禮節; 儀式) ceremony; rite 3 (禮物)present; gift 4 ...
  • 電解 : electrolyze; electrolysis; electrolyzation; galvanolysis 電解銅 [冶金學] electrolytic [cathode] c...
  1. 4. practical meteorology : isopleths analysis ; streamline analysis ; use of tephigram ; interpretation of weather charts ; weather observations ; codes in common use ; principles and exposure requirements of weather instruments ; telecommunications procedures

    4 .實用氣象學:等值線流線溫熵圖應用天氣圖釋天氣觀測通用碼氣象器原理及安裝條件信程序。
  2. Elimination of the troubles in easylyte sampler of

    常見故障的排除
  3. This paper starts the research of the liquid floated pendulous accelerometer testing system according to the engineering. at first, this paper gives the brief introduction of the history and present status of accelerometer and its testing technology, the working principium and math model of the liquid floated pendu - lous accelerometer, and then, decides the binary width pulse force retrim loop as the design proposal of testing system, researches the transfer function of every part in the system emphasizly, analyses the stability of the whole accelerometer testing system from the angle of control theoretics by the open loop transfer function of system, and designed the correcting net, analyses the basal problems such as resolution, sampling restraint, precision and so on, designs the hardware testing circuits such as preamplification, band - pass filter, alternating amplifier, phase sensitive demodulatorn, pulse - width modulation, frequency scale circuit, moment current generator. finally, using the graphics program language labv - iew which is designed for testing field especially by ni accomplishes the solfware design of testing system, realized the testing functions

    首先對加速度計及其測試技術的發展歷史和現狀,液浮擺式加速度計的工作原理和數學模型等作了簡要的介紹,然後確定了以二元調寬脈沖再平衡測試迴路為設計方案,並從控制理論的角度進行了,著重研究了系統中各部的傳遞函數,利用系統開環傳遞函數了系統的穩定性,同時設計了系統的校正網路;了二元調寬脈沖再平衡測試迴路的度、采樣約束以及測試精度等基本問題,並按照系統的結果設計了包括前置放大、帶通濾波、交流放大、相敏調、脈寬調制、頻標路以及力矩流發生器等測試系統各部硬體路,驗證了路的正確性,最後按照測試系統的要求,採用了美國ni公司專為測試領域所開發的虛擬器工具? ? labview作為測試軟體開發工具,利用該圖形化編程語言完成了測試系統軟體部的設計,實現了測試功能。
  4. The primary theory of absorption and desorption was also explained. the effects of primary process parameters, such as hydrogen pressure, time and temperature on the magnetic properties of ndfeb have been researched. the structure and magnetic properties have been analyzed by means of optical metallographic microscopy, scanning electronic microscopy, x - ray diffraction analysis, infrared oxygen detector and magnetic properties measurement

    本文設計了燒結ndfeb的氫爆制粉設備,對設備調試以及使用過程中出現的主要問題進行了簡要的說明,提出了一系列決方法;闡述了吸氫、脫氫的基本原理;研究了氫氣壓力、通氫時間、氫爆溫度等基本工藝參數對磁性能的影響;利用金相顯微鏡和掃描子顯微鏡, x射線衍射,紅外線測氧及綜合磁性測量等手段了材料的組織結構和磁性能。
  5. The explanation and clinical usage of electrochemiluminescence immunoassay and instrument

    化學發光免疫器的及臨床應用
  6. ( 2 ) different calculating schemes are designed which are used to analyze in detail the characteristics of the effect from instrumental bias ( ib ) in gps observations on determining ionospheric delays

    ( 2 )設計了幾種不同的計算方案,用於器偏差對確定離層延遲的影響的特點。研究表明,器偏差對求離層延遲的影響遠大於觀測噪聲的影響,給離層延遲觀測值帶來高達數米的系統誤差。
  7. The application of the tri - electrodes balances - like dissolved oxygen analyzer

    極平衡式溶的應用
  8. Expression of performance of electrochemical analyzers ; part 4 : dissolved oxygen in water measured by membrane covered amperometric sensors

    化學性能的表示法.第4部:用包有薄膜的流傳感測量的水中溶
  9. Test method for rapid thermal degradation of solid electrical insulating materials by thermogravimetric method

    重量法對固體絕緣材料快速熱降的試驗方法
  10. The stability of nano - alumina aqueous dispersion is tokened by spectrophotometer and particle size distribution instrument. it is proved that when condition is dispersant pmaa = 0. 4 %, ph = 9, nano - - alumina content = 4 % ( wt % ), ultrasonic for twenty minites, excellent stable nano - alumina aqueous dispersion can be acquired. nano particle average size is 205nm

    光光度計和粒度表徵了納米粒子水散液的穩定性,結果表明納米相al2o3濃度為4 % ,散劑為陰離子聚質,用量0 . 4 % , ph = 9 ,採用超聲波散20鐘得到最好的散效果,納米顆粒的平均粒徑為205nm 。
  11. Sample error probably caused from data collection circuit of rf virtual frequency spectrum analyzer instrument was emphasized, and some kinds of selectable resolution scheme were presented, then these schemes of advantages and disadvantages were compared and summarized by the way of theory analyse, matlab simulation and practice validate and so on, at last, the optimum scheme of rf virtual frequency analyzer instrument was decided and adopted

    重點對虛擬射頻頻譜中的數據採集路可能造成的采樣誤差進行了,提出了幾種可供選擇的決方案,經過理論、 matlab模擬和實際驗證等手段,對這幾種方案的優缺點進行了比較和總結,並最終確定了其中最適合虛擬射頻頻譜的方案。
  12. Utilizing the scanning electron microscope, x - ray diffractometer, type 9310 microporosity analyzer, the microstructure and chemical composition of mudston, and its macro - variation of physical and mechanical character are measured and analysed, the mechanism of mudstone degradation and softening in water is systematically studied in this paper

    以掃描子顯微鏡、 x射線衍射、 9310型微孔結構等先進的設備為測試手段,從泥巖的微觀結構及物質組成等方面入手進行研究,結合泥巖遇水后宏觀物理-力學性質的變化規律,全面闡述了泥巖遇水的崩軟化機理。
  13. Expression of performance of electrochemical analyzers - part 3 : electrolytic conductivity iec 60746 - 3 : 2002 corrigendum 2002 ; german version en 60746 - 3 : 2002

    化學性能表達.第3部:
  14. Then based on the principle for pcr, 20 - cycle continuous - flow pcr is designed using cad software. to the designed 20 - cycle continuous - flow pcr chip, a krf excimer laser ( direct write method ) is adopted as the fabrication technology, and the polymethyl methacrylate ( pmma ) is selected as the substrate. so the appearances of pmma surface etched before and after by 248nm excimer laser under different incident fluences are analyzed using sem

    為此在應用掃描鏡和三維形貌對pmma表面被準子激光刻蝕前後的形貌、刻蝕粗糙度以及單脈沖刻蝕率等進行詳細的基礎之上,總結出了準子激光刻蝕pmma的宏觀規律和微觀刻蝕機制,提出了一種準子激光刻蝕pmma的是光熱光化學以及羽輝共同作用的理論釋。
  15. The software function modules, such as data acquisition, data processing, human - machine interface and data management, are introduced. the crucial software design concepts of using multithread and double buffers for exchanging data are emphasized. the data transmission between the data collecting site and supervision center is implemented for constructing a distribute supervision system based on the network

    本文能質量在線設計中的各種問題以及決的方法;介紹了軟體系統中數據採集、數據處理、人機交互和數據管理等四個模塊的功能和實現;詳細說明了如何利用多線程的編程方法和雙緩沖區的數據交換方式,實現對能質量各個技術指標的實時監測、記錄和;實現了在數據採集點和監控中心之間數據的傳輸,並在此基礎上設計了基於網路的散式能質量測試系統。
  16. At the same time other domestic manufacturers integrated electronic control system fault diagnosis and other peripheral modules can be matching function modules, complementarity of the engine analyzer and decoder of advantages and disadvantages, making it maintenance personnel accede to the demands of open testing work platform

    同時集成了國內其他廠家控系統故障診斷模塊及其它周邊可選配功能模塊,互補了發動機碼器的優、缺點,使其成為維修人員有求必應的開放式檢測工作平臺。
  17. Sodium electrolyte analyzer

  18. Task scheduling and applications study of electrolyte analyzer in real - time operating system

    中的任務調度及應用
  19. Preparation of reagent and clinical use of il - 1400 blood - gas electrolyte analyzer

    1400型血氣系列試劑的配製及臨床應用
  20. Task division and task priority were applied to the electrolyte analyzer system, which not only reduced the development work burden, but made the most use of the cpu resources of the system and made the system even more user - friendly

    任務劃和任務優先級在系統中的應用,不僅減少了開發工作的負擔,而且使系統主cpu的資源得到了充利用,使得該系統的功能結構更加入性化。
分享友人