靈敏度測量計 的英文怎麼說
中文拼音 [língmǐndùcèliángjì]
靈敏度測量計
英文
sensitivity meter- 靈 : Ⅰ形容詞1 (靈活; 靈巧) quick; clever; bright 2 (靈驗) effective Ⅱ名詞1 (精神; 靈魂) spirit; ...
- 敏 : Ⅰ形容詞(靈敏;敏捷) quick; agile; smart; nimble Ⅱ名詞(姓氏) a surname
- 度 : 度動詞[書面語] (推測; 估計) surmise; estimate
- 測 : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
- 量 : 量動1. (度量) measure 2. (估量) estimate; size up
- 計 : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
- 靈敏度 : [電子學] sensitivity; response rate; sensibility; sensitiveness; response; susceptibility; suscep...
- 靈敏 : sensitive; keen; quick; agile; acute
- 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
-
This paper deriving the theory work inflection point in the static stage characteristics curve of small measurement range linear dimension measurement. by the way of high pressure and back pressure pneumatic measure and designed the parameter of the mainly and measure spray head, which are the key component in the spray head - baffle pneumatic sensor. the different groups for the main - spray head and the measure spray head, will effect the dynamic and static stage characteristic parameter. the author have done contrast experiment and optimization design to test and verify the theory derivation whereby made the rang of show valve of pneumatic measure system measure range up to 40 u m, the sensitivity up to 100mv / u m, resolution up to 0. 05 p m, the uncertainly of measure is less than 0. o2 u m, satisfaction of requirement of groups the carboy hatch thickness size precise measure of soft shims
對高壓背壓式氣動測量用於小量程線性尺寸測量的靜態特性曲線的理論工作拐點進行了推導,對氣動測量系統中的噴嘴-擋板型氣動傳感器中的關鍵部件? ?主噴嘴和測量噴嘴的參數進行了理論設計,對主噴嘴和測量噴嘴的不同組合,將影響測量系統靜、動態特性指標的噴嘴參數進行了對比實驗和優化設計,並通過實驗驗證了理論推導,從而使氣動測量系統量程的示值范圍達到40 m ,靈敏度達到100mv m ,解析度達到0 . 05 m ,測量不確定度小於0 . 2 m ,滿足了壓縮機缸蓋軟體墊片厚度尺寸精密測量分組的要求。After reference solution has been formulated and sensitivity has been adjusted and tested according to above mentioned method ( 3 ), take appropriate amount of test sample solution and reference solution, blend samples separately ; unless otherwise specified, recording time of the former should be 2 times of retention time of chromatographic peak of main component, measure peak area of each impurity on the chromatograph chart of test sample solution, and compare with peak area of main components of reference solution, then calculate content of each impurity accordingly
同上述( 3 )法配製對照溶液並調節檢測靈敏度后,取供試品溶液和對照溶液適且,分別迸樣,前者的記錄時間,除另有規定外,應為主成分色譜峰保留時間的2倍,測量供試品溶液色譜圖上各雜質的峰面積並與對照溶液主成分的峰面積比較,計算雜質含量。However, one of the most serious impediments to wider use and improve precision of psi is its sensitivity to external vibration with the consequence that psi has rarely been used in a manufacturing in - situ and some special situations, such as that the optical path is very long or the detected unit is very large
通過嚴格控制環境條件(溫度、氣流、振動等) ,其理論光程差(位相)的最小解析度可以達到nm的數量級。然而,由於干涉計量測試靈敏度高、精度高,對外界振動非常敏感,使它的應用范圍受到限制。According to the guidline, two nd : yag lasers have been designed and set up, one is end - pumped by lower output power ld using a selfoc micro lens, and the other is end - pumped by high output power ld using a pair of lenses are designed, and the characteristics such as output power and power stabilization of both solid - state lasers are investigated. thirdly, when an empty liquid crystal cell is inserted in the cavity of the nd : yag laser pumped by high power ld, the laser can operates in single axial mode. finally, according to the relationship between the laser output power and the longnitudinal a ld - end - pumped nd : yag laser sensor for displacement measurement has been investigated theoretically and demonstrated experimently, the results indicate that when the mean radius of pumping inside the laser cavity is far less than that of the oscilating laser mode, the exponential of the output power is a gauss function of the longitudinal positon of focused spot of ld pumping beam, both the measurement range and the sensitivity are dependent on the incident pumping power, as the incident pumping power is increased, the measurement range is enlarged and the sensitivity is improve d
本文首先介紹了ld泵浦nd : yag激光器的發展狀況、主要特性及其應用,從四能級速率方程出發,推導了ld泵浦nd : yag激光器的閾值、輸出功率和斜效率的表達式,並簡述了激光器的工作原理、結構型式和倍頻方法;其次,以空間相關的速率方程為基礎,提出了ld端面泵浦nd : yag激光器的設計方法,給出了一定泵浦耦合方式下,振蕩光模尺寸、最佳輸出耦合率、泵浦光模尺寸、泵浦光焦斑位置等參數的選取依據,以此為依據,設計了自聚焦透鏡耦合小功率ld泵浦nd : yag激光器和透鏡組耦合高功率ld泵浦nd : yag激光器,對激光器的輸出功率和功率穩定性等特性進行了實驗研究;再次,在帶尾纖輸出的高功率ld泵浦nd : yag激光腔內插入一隻空液晶盒,觀察到了激光器以單縱模運轉;最後,根據泵浦光焦斑端面位置對激光輸出功率的影響規律,提出了ld端面泵浦nd : yag激光位移傳感新方法,並進行了理論和實驗研究,研究結果表明:當激光晶體內泵浦光平均光斑半徑遠小於振西安理工大學碩士學位論文蕩光束腰半徑時,激光輸出功率的自然指數與泵浦光焦斑的縱向位置成高斯變化規律,測量范圍和靈敏度依賴于泵浦功率,隨著泵浦功率的增加,測量范圍擴大,靈敏度提高,當端面泵浦功率為7 . 24w (最大輸出功率為1 . 926w )時,激光位移傳感器的測量范圍和靈敏度分別是13 . 045mm和0 . 148mw / pm 。In order to make the sensitivity of 2 - demension accelerometer along the two main arbors almost identical, symmetric four - beam structure that embeds a double - sides interdigitated differential capacitive with puckered beam in two directions was used as sensitive component. in addition, the differential capacitive accelerometer fabricated by bulky silicon micromechanical technique has high sensitivity, wide measurement scope, less nonlinear error, and simple converting circuit. then, the structure parameters of the sensitive component were calculated and stimulated, which results in a set of the optimized structure design parameters, main fabrication procedure and several key fabrication technology
為使二維振動傳感器在兩主軸方向的靈敏度大致相同,敏感元件採用高度對稱的四梁結構,其中每個軸向上均採用帶折疊梁的雙側叉指電容結構,採用體硅微機械工藝製作的高深寬比叉指電容式敏感元件,具有高靈敏度、寬量程、非線性誤差小、外圍電路簡單等優點;對設計的敏感元件結構參數進行了計算,並利用有限元法進行了模擬分析,根據模擬結果得出了優化參數;在確定敏感結構的基礎上,研究了敏感元件採用體硅微機械加工工藝製作的工藝流程和關鍵工藝技術;對敏感晶元內部的c - v介面電路進行了原理設計與分析,利用差動測量技術得到由振動引起的微小電容變化量,經c - v介面電路進行相位調制處理,然後通過解調輸出與加速度成正比的電壓信號。On the basis of increasing the flaw resolution of the x - ray radiographic system, the study is firstly concerned with the analysis made on the influence of such factors as redial sources energy, system noise, optics radiography and scattering on the radiographic system in theory, and the present dissertation looks at the methods for acquiring the radiographic system point sp read function, line spread function and module transfer function ( mtf ). on the basis of these studies, research the spread properties of the tiny flaw making use of mtf, acquiring the properties of system inspecting sensitivity and resolution, based on the system optimization designing
本文以提高射線成像系統的疵病解析度為前提,首先在理論上對射線源能量、系統噪聲、光學成像、散射等各環節對成像系統的影響進行分析,探討成像系統的點擴展函數、線擴展函數及其調制傳遞函數( moduletransferfunction ,簡稱mtf )獲取方法,在此基礎上,利用mtf研究微小疵病的擴展特點,從而得到系統的檢測靈敏度和解析度給出關系特性,為系統優化設計提供依據。The bleaching experiment of loess by iodine tungsten lamp and the equivalent dose ( de ) of loess estimated by sar from the earth ' s surface indicate that loess can be easily bleached by sunlight, and osl is suitable for the dating of loess. 2. equivalent dose estimated by sar, when each natural or regenerated dose osl measurement is corrected for changes in sensitivity using the osl response to a subsequent test dose and the recycling ratio is around 1, implies that sensitivity changes have been properly corrected
用單片再生劑量法( sar )測定黃土樣品的d _ e值時,用固定的實驗劑量釋光信號校正後,再循環比( recyclingratio )都在1左右,說明對釋光靈敏度的變化起到了很好地校正作用;校正後, ogy再生劑量釋光信號與自然信號的比率都在5以下,信號的回復可以忽略不計。This paper designs an optical system based on above to measure the small angle of the laser beam. a non - polarized beam splitter ( npbs ) is used to split the incident beam into two branches, and a rhombic prism agglutinated by two right - angle prisms is placed to realize total internal reflection twice in each branch. it not only improves the measurement sensitivity and linearity, but also increases antinoise ability by the differential optics
本文正是基於這一原理設計了測量光束微小偏轉角的光路系統,用消偏振分光棱鏡將入射光分為兩路,並在兩路分別用兩個直角棱鏡組成的斜方棱鏡來實現兩次全內反射,不但提高了測量靈敏度和線性,還利用差分光路的特點提高了抗干擾能力。This product adopts oem pressure transducer with stainless steel isolation diaphragm as signal measure element and automatic testing by the computer. using laser adjustment resistant technology carries on temperature compensation to zero point and sensibility in width temperature scope
該產品採用帶不銹鋼隔離膜片的oem壓力傳感器作為信號測量元件並經過計算機自動測試,用激光調阻工藝進行了寬溫度范圍的零點和靈敏度溫度補償。Finite difference time - domain method is used to calculate the reflection for these probes and absorbing boundary condition is used to deal with the singularity in the axis of the coaxial - line in the simulation. by comparing the reflection of different probes, the best probe has been selected according to sensitive requirement. the influence of parameters : such as thickness of protective film, length of protruding inner conductor of the coaxial - line probe to the measurement has been studied
通過時域有限差分法進行數值模擬分析,並採用吸收邊界處理同軸線軸心奇異點,計算出各種探頭測量相同溶液的反射系數,根據其測量的靈敏度,選出最優設計;並通過分析所選探頭的各種設計參數,如薄膜厚度、內導體伸出長度等的變化對測量結果的影響,找出該探頭各參數的最佳范圍,使其具有高度靈敏性,以適用於測量化學反應溶液的介電常數。Under our task experimental condition, we calculated the sensitivity of our planning to develop dial system with direct detection, besides, we studied the relationship between the sensitivity of measurement and atmospheric refractive - index structure constant and applied matlab program simulated the system parameters such as beam diameter, laser divergence angle, detection distance and gained relevant relationship curves
在課題實驗條件下,模擬計算了直接檢測dial系統的測量靈敏度。在考慮大氣折射率結構常數對系統測量靈敏度影響的基礎上,並對各種系統參數如光束半徑、束散角和探測距離對測量靈敏度的影響運用matlab程序做了模擬計算,為合理選擇系統設計參數提供了依據。2. the design thought of annular fan beam sensor structure is presented, and array laser sensor of 15x5 fan beams structure was developed. the sensor ' s measurement sensitivity distribution and spatial resolution are analyzed and calculated
提出了環形扇束傳感器結構的設計思想,並研製了15 5扇束結構的陣列式激光傳感器,以及對其測量靈敏度分佈和空間解析度等性能指標進行了分析計算。Systemic numerical tests are made first, to study the parameter sensitivity of cohesion and friction angle and other elastic parameters to the convergence in tunnel. some comprehensive parameter sensitivity laws have been draw thought these numerical tests. the method of emulating back analysis is illustrated secondly, in detail by tracing the excavation and supporting conditions by the special numerical modeling rested in final program
主要研究成果: ( 1 )建立使各個參數靈敏度值具有可比性的靈敏度計算公式,不僅得到了靈敏度分佈規律,而且還得到了各參數對位移的量化影響結果; ( 2 )詳細闡述了巖土工程模擬反演分析思路與具體方法; ( 3 )假定圍巖為理想彈塑性模型,在可量測出理論上認為不可測的塑性變形、實現彈塑性位移分離的前提下,提出了彈塑性問題的分步反分析法。With the experiment, the author believes that electrostatic transducer technology has several characteristics as the new means of mass flow rate measurement technique : its structure design is very novel and can be prone to be installed, it is more suitable for the measurement on the mass flow rate of the coal particulate in larger caliber pipelines and has higher delicacy in the measurement on both dilute and dense phases
通過實驗,作者認為靜電傳感技術作為一種新興的質量流量測量技術具有以下特點:靜電傳感器結構設計新穎,易於安裝,適合於大口徑管道中煤粉顆粒的質量流量測量,對稀相及濃相測試均具有較高的靈敏度。The method that increases the attitude accuracy of strapdown inertial attitude and heading reference system ( siahrs ) with the infromation from inertial measurement unit ( imu ) its own is studied. according to the design idea of damping network in platform type, damping kalman filter in siahrs is designed to enhance the attitude accuracy via integrating attitude calculated by common siahrs and that estimated by accelerometers. in order to evaluate the effectiveness of damping attitude, the vehicle ' s movement should be detected in real - time. for this reason, the state chi - square test is employed in the damping kalman filter, and the failure detection vector are tested, which improves the sensitivity and reliability of failure detection. finally, static and dynamic experiments of actual system demonstrate the effectiveness of the proposed method
本文探討了如何利用慣性測量組合本身的信息來提高捷聯航姿系統的姿態精度.根據平臺式阻尼網路的思想,設計了捷聯式內阻尼卡爾曼濾波器,將慣導系統捷聯解算獲得的姿態與加速度計估計的姿態進行組合,在系統非加速度狀態下,提高了姿態輸出的精度.為了實時監測系統的運動狀態從而判斷內阻尼姿態的有效性,本文成功將狀態2檢驗法應用在內阻尼卡爾曼濾波器中,設計了基於2個狀態傳播器的故障監測器,並通過對故障檢測向量元素的檢驗代替對整個向量的檢驗,提高了故障監測的靈敏度和可靠性.最後,實際系統的動靜態實驗驗證了本文所提出的方法的有效性The system uses hpc as a detector, based on the computer and network technology, reaches the design requirements of high - sensitivity, wider range, full automation and no - man on duty
該系統採用高壓電離室為探測器,利用計算機及網路技術,基本達到了靈敏度高、量程寬、全自動無人值守的設計要求。X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - dosimetry for radiation protection over the energy ranges 8 kev to 1, 3 mev and 4 mev to 9 mev
校準劑量計和劑量強度計及測定作為光子能函數靈敏度用x和基準放射線.能量范圍在8kev - 1 , 3mev和4mev - 9mev放射保護用放射量測定In order to study the thermal performance and residual stress of microelectronic subassembly, in this paper, a newly optical interferometry method for 3 - d displacement measurement is developed based on wavefront interference theory. in which the moire interferometry provide the in - plane displacement, but the system is different from the conventional interferometry, the system applies the double diffraction of the specimen grating, the in - plane displacement sensitivity is a factor of 2 higher than that of the conventional moire interferometer. twyman / green interferometry method for out - of - plane displacement measurement is adapted, the advantages of the optical set - up are structure novelty, and the fringe patterns of the displacement fields shown high contrast and spatial resolution
為了詳細研究試件的熱變形特徵以及殘余應力的影響作用,本文在波前干涉理論的基礎上,設計了一新型三維光學測試系統,該系統的平面位移測試基於雲紋干涉方法,但採用與普通雲紋干涉不同的光路系統,利用試件光柵和平面反射鏡組形成的兩次衍射,使平面位移干涉條紋倍增,測量靈敏度是普通雲紋干涉的2倍,系統的離面位移場測試採用泰曼格林干涉光路。The results of calculation prove : the new structured coaxial probe is superior to the traditional coaxial probe in both sensitivity and penetrating depth when used to measure the dielectric properties of chemical reactants or layered biological tissues, and the relationship between the measurement sensitivity of this new structured probe and the frequency of electromagnetic wave are obtained, which provides the optimal frequency for the actual application
計算結果表明:在化學反應溶液及生物分層組織介電特性參數的測量中,這種新型的同軸探頭在測量靈敏度及透入深度兩方面都優于傳統的平口同軸探頭。通過計算模擬還得出了這種新型同軸線探頭的測量靈敏度與電磁波頻率的關系,為進一步研究其最佳測試頻率提供了有價值的參考依據。5. the measuring end of protective tube is of ultra thin design, which greatly reduces time of heat conductionand increase sensitivity of thermocouple
5超簿的測量端保護套管設計,極大的減少熱傳遞時間,大大的提高了熱電偶的靈敏度。分享友人