顯微鏡成像 的英文怎麼說
中文拼音 [xiǎnwéijìngchéngxiàng]
顯微鏡成像
英文
microscopic imaging- 顯 : Ⅰ形容詞1 (明顯) apparent; obvious; noticeable; evident 2 (有名聲有權勢的) illustrious and inf...
- 鏡 : Ⅰ名詞1 (鏡子) looking glass; mirror 2 (幫助視力或做光學實驗的器具) lens; glass 3 (姓氏) a s...
- 成 : Ⅰ動詞1 (完成; 成功) accomplish; succeed 2 (成為; 變為) become; turn into 3 (成全) help comp...
- 像 : Ⅰ名詞1 (比照人物製成的形象) likeness (of sb ); portrait; picture 2 [物理學] image Ⅱ動詞1 (在...
- 顯微鏡 : microscope
- 顯微 : microadiography
-
The microscope image contains contrast effects.
顯微鏡所成的圖像具有反差效應。Imaging signals used in scanning electron microscope
掃描電子顯微鏡成像信號分析This is the microscopic appearance of a lacunar infarct. note that it is a cystic space from the resolved liquefactive necrosis. there can be hemosiderin pigment from hemorrhage as well
腔隙性梗死顯微鏡圖像。注意液化性壞死溶解形成的囊性空腔。也可出現出血形成的含鐵血黃素。Light microscopes - specification for the magnifying power of microscope imaging components
光學顯微鏡.顯微鏡成像部件放大率規范The system is composed of an medical microscopy, a video image sampling card, a computer system and software what we developed specially for this system. further more, it provides many powerful functions including pathologic image recording, image sampling, image processing, parameter measurement, result analysis, report creating, report printing and so on
該系統集醫用顯微鏡、視頻圖像採集卡、計算機系統於一體,實現了從病理圖像記錄、採集、預處理到特徵參數測量、結果分析、報告生成、列印等一系列功能。It was based on the principle of laser confocal microscope. and the two - dimensional scanning configuration was adopted by the optical scanner and the telecentric linear imaging objective lens of large numerical aperture to realize x - direction ' s scanning, and the conventional mechanical method using linear driver and linear guide track to y - direction ' s. the experiment results indicate that the device can run smoothly and rapidly, be operated easily and detect fluorescence effectively
儀器基於激光共焦顯微鏡的理論,採用振鏡和遠心線性成像物鏡實現x向掃描;精密導軌和步進電機實現y向掃描的檢測儀,經驗證,掃描儀具有快速、操作簡單、檢測晶元能力良好等特徵,有望彌補市場的空缺。There are many methods to investigate domains, such as polarization microscopy, scanning electron microscopy, transmission electron microscopy, scanning electron acoustic microscopy and so on. however, these methods suffer from some serious disadvantages involving complex sample preparation, damage to sample, low resolution
現有的鐵電疇檢測手段,如偏光顯微鏡、粉末花樣技術、掃描電鏡、透射電鏡、掃描電子聲顯微鏡等存在這樣或那樣的缺點:諸如制樣繁瑣、易破壞原始疇結構、或疇結構成像解析度還不夠高等。Improved atomic force microscope imaging in liquid with active probe
壓電探針應用於原子力顯微鏡液體成像的研究Vacuum system and imaging signal in environmental scanning electron microscope
環境掃描電子顯微鏡中真空系統特點及成像信號分析Abstract : based on the electronic focus technology development of state - of - the - art, the paper suggested a complete apparatus s cheme ofauto - focus based on sspd ( self - scanned photodiode array ) and 8098 singl e chipprocessor, giving out a focus criterion algorithm based on image high freq uencystatistics. the function of auto - focus of both reflected and transparent o pticalmicroscope was realized. meanwhile some corresponding problems such as sta bility of lightsource, step motor driving etc. were also discussed, which greatly improved the accuracy andreliability of the system
文摘:在介紹與分析了國內外電子調焦系統的技術發展與現狀的基礎上,提出了一種基於sspd (自掃描光電二極體列陣)與8098單片微處理器自動調焦的整體技術方案,給出了基於圖像高頻成分統計的聚焦判識演算法,在此基礎上實現了反射式與透射式光學顯微鏡的自動調焦,同時對系統的可靠性有關的其它相關問題如光源穩定性、步進電機驅動等問題也進行了討論。China university of science and technology li yin - mei group, proposed to dark field microscopy observation of light scattering technology and optical tweezers capture the idea of combining the traditional optical microscope optical tweezers system from the side of a bouquet of flake coupling laser irradiation samples, laser incident in a specific location, so that samples of the particles scattered light through the microscope imaging ; overcome the well - optical tweezers and microscopic imaging of laser irradiation, as well as strictly coincidence of the three key technologies to achieve the optical tweezers capture 100 nanometer - styrene ball at the same time also in the entire field of view of microscopic observation of nano - particles, to capture optical tweezers nanoparticles can also observation purposes
中國科學技術大學李銀妹課題組,提出將暗場顯微術觀察光散射的技術與光鑷捕獲相結合的設想,在傳統光學顯微鏡光鑷系統上從側面耦合一束片狀激光照射樣品,在特定的激光入射位置,使樣品中粒子的散射光可通過顯微鏡成像;克服光鑷的阱位與顯微成像面以及激光照射面三者嚴格重合的技術關鍵,實現了光鑷捕獲100納米聚苯乙烯小球的同時也能在整個顯微視場中觀察納米粒子,達到了光鑷捕獲納米粒子的同時也能觀測的目的。On the base of studying imaging theory of lens, the imaging theory of laser confocal scanning microscopy was analyzed in detail in this paper, and the advancement of that the optical fiber was applied to the system was described ; on the base of completed the demonstration for whole project, the experiment scheme was designed ; the relationship between the main parameters of key devices and the resolution was deduced, and the requirements of coupling efficiency and vignetting effects to optical system was analyzed ; the design of optical system and the planar scanning controlling circuit was completed ; a new method was put forward to resolved the inherent non - liner scanning problem of the galvanometer scanner by using software liner controlling in circuit design, and the perfect planar scanning was realized ; at last the low noise, high multiple and non - distortion amplify circuit of photoelectric detector was completed
本文在透鏡成像理論的基礎上,系統、深入地分析了共焦掃描顯微成像的機理,論述了應用單模光纖的激光共焦掃描顯微成像系統的優點;進行了總體方案的論證,並設計確定了單模光纖激光共焦掃描顯微成像系統的總體方案;從理論上推導分析了解析度要求與試驗系統中相關器件主要參數之間的關系,分析了系統耦合效率和漸暈現象對光學系統的設計要求;完成了方案中光學系統和二維掃描控制電路的設計,並在電路設計中採用了用軟體解決檢流計式光學掃描器(振鏡)非線性問題的新方法,能夠實現較為理想的二維模擬掃描;完成了高增益、低噪聲和低失真的探測接收系統的設計和調試。The confocal laser scanning microscope ( clsm ) is a new kind of microscope that based on the confocal imaging technology. through the laser scanning and digital image manipulation, it could make the 3 - d dynamic measurement of the sample
共聚焦激光掃描顯微鏡是一種新型的顯微設備,它以光學系統共焦成像為基礎,利用激光掃描技術和數字圖像處理技術,可以對樣品進行三維動態測量。Fluorescence power transfer function, three - dimensional point spread function ( 3d - psf ) and three - dimensional optical transfer function ( sd - otf ) for the various fluorescent wavelength of the two kinds of fluorescence confocal scanning microscopy are calculated in this paper by using fourier imaging theory. the results show that the fluorescent wavelength has influence on imaging property of confocal microscopy such as spatial cut - off frequency, resolution and 3d - otf. there is a different missing - cone in the 3 - d space of otf when the ratio of excitation wavelength to fluorescent wavelength decreases
本文在sheppard和gumin等人的理論基礎上,利用fourier光學成像理論,討論了不同熒光波長對單光子和雙光子共焦顯微鏡成像特性的影響,導出了單光子和雙光子共焦顯微鏡的熒光功率傳輸函數、三維脈沖響應函數和三維光學傳遞函數,得到了它們在不同激發波長與熒光波長比值時具體的表達式,並且通過數值計算,得到了它們的曲線圖,結果表明:隨著激發波長與熒光波長比值的增加,焦斑的橫向分佈和縱向分佈變窄,橫向解析度和縱向解析度提高,系統的成像效果變好,當激發波長與熒光波長的比值下降到一定程度時,可以看到不同程度的失錐現象。Because of the nonlinear effect, the imaging property of two - photon confocal microscopy is very different from that of the conventional confocal microscopy. that the fluorescent wavelength equals to the excitation wavelength has been discussed theoretically as we know
在僅有的理論研究中,絕大多數文獻都只是討論了熒光波長等於激發波長這一特殊情況,很少討論不同熒光波長對共焦顯微鏡成像特性的影響。For emulsions, interfacial structures, droplet sizes and distribution, and droplet motion and coalescence could be observed and recorded in situ by an integration device including a microscope, a pickup camera, a video tape recorder, and a computer with a gathering image card and a programme
利用光學顯微鏡攝像錄像計算機圖像採集、處理集成系統,可實現對乳狀液界面結構,液珠大小及其分佈,液珠運動和聚並的動態過程進行實時觀測、錄像、圖像採集和處理。According to the law of an image formed by a microscope, a method is given which judges lines on the surface of the examined workpiece to be sunken or raised, and the method is proved to test the experiment
摘要根據顯微鏡成像規律,給出了被檢工件表面的紋路是凹還是凸的判定方法,該方法經受了實驗的檢驗。Some methods such as image cytophotometry, fluorescence microscopic imaging, infrared ( nearinfrared ) and raman microscopic imaging, magnetic resonance imaging and scanning probe microscopic imaging are discussed emphatically, and the conceivable direction in the future has been suggested
重點討論了圖像細胞光度測量、熒光顯微成像、紅外(近紅外)與拉曼顯微成像、磁共振成像和掃描探針顯微鏡成像等技術,並展望了單細胞成像的發展前景。Quantiative relationship between transmission electron microscopy image quality and specimen tilt angle
電子顯微鏡成像質量與樣品傾斜角度關系的數值化評價This pathological picture analytical instrument is a kind of pathological picture analytical system for the use of diagnosis, which is composed of the applications of many cell heredity pictures, microscopes and systematical lens
該系統由許多細胞遺傳圖像應用軟體與顯微鏡、攝像頭組成的靈活可變的細胞遺傳圖像分析系統,以滿足您所需的診斷要求。分享友人