風冷式變壓器 的英文怎麼說

中文拼音 [fēnglěngshìbiàn]
風冷式變壓器 英文
air blast tra former
  • : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
  • : 壓構詞成分。
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. For the existing transformer cooling control system has many shortcomings such as the complicated system control circuit, the low reliability, the protection methods of blower fan being so simple, large control error, high fault rate, massive maintenance work and no method to realize telecommunication, this thesis develops a novel intelligent power transformer air - cooled control system based on the center of microprocessor through all - round technology analysis and research

    本文針對卻系統使用常規控制系統存在的系統控制迴路復雜、可靠性低、機的保護方簡單而無法進行故障預測、主油溫測量精度低造成控制誤差大、故障率高、維護工作量大、無法實現遠程通訊等問題,經過多方面的技術分析和調研,設計開發了新型的以微處理為核心的智能電力控制系統。
  2. Transverse - flow type ventilators for dry - type transformers

    用橫流
  3. The research results show that the counter - flow condensers have a better performance than that of other arrangements in single - circuit condensers, and that branch flow should be adopted in multi - rows condensers to decrease the pressure drop and increase the heat transfer capacity, and that the influence of gravity force can not be ignored, and that there must be an optimum refrigerant mass flow which can make the condenser perform best when the air velocity is constant while there must be an optimum air flow which can make the condenser perform best when the refrigerant mass flow is constant

    研究結果表明,單迴路中,逆流布置換熱效果最好,叉流其次,順流最差;多排管應盡可能採用分流方,以減小降,增強換熱;布置流程時,重力的影響不可忽略;當量不時,必然存在一最佳製劑流量使性能達到最佳;當製劑流量保持不時,也相應存在一個最佳量使性能最佳。
  4. By close study on the average temperature rise, temperature distribution, and tune constant of the class f resin dry type power transformer ' s high voltage and low voltage winding under self - cooling and wind - cooling mode, we find out the connection between the variation of the load and the items, mentioned above. the results of the experiments can be reference to both thermal design optimization of dry type power transformer and the revision of current standards. meanwhile, we develop the software, which can predict the overload ability of the dry type power transformer

    本文對f級樹脂澆注的高、低線圈的平均溫升,內部溫度分佈和時間常數在自,兩種卻方下隨負載化的規律進行了研究,得出了平均溫升、熱點溫升和時間常數隨負載化的相互關系和有關計算用參數和公,試驗結果可作為改進乾電力的熱設計的依據和對現行標準進行修改的參考。