air-flow distribution 中文意思是什麼

air-flow distribution 解釋
氣流分配
  • air : n 1 空氣,大氣。2 天空,空中。3 微風,和風。4 態度,樣子,風度,氣派;〈pl 〉高傲的架子。5 傳播,...
  • flow : vi 1 流,流動。2 (血液等)流通,循環。3 流過;川流不息;(時間)飛逝;(言語等)流暢。4 (衣服、...
  • distribution : n 1 分配,分發,配給;分配裝置[系統];配給品;配給量;【經濟學】配給方法,配給過程;分紅;【法律...
  1. Abstract : apply computer simulation to the distribution pattern of air - flow without considering the cold condition of the combustion and compare the flow patterns under different designed circumstances. and the effect of the design of the partition in the air way of the burner on the flow and mixture of gas and air is especially studied. the result shows that the design of partition plays a very important role in strengthening the mixture of gas and air, but increases the loss of the resistance in the air way and the total pressure of the air way in same working conditions needs increasing

    文摘:應用計算機模擬的方法,在不考慮燃燒的冷態情況下,研究了熱風爐燃燒室內的氣流分佈規律.在此基礎上,比較了2種不同設計方案的氣流流動特徵,尤其是研究了燃燒器空氣通道內阻流板的設置與否對空氣和煤氣的流動和混合的影響.結果表明,阻流板的設計對加強空氣和煤氣的混合有著極為重要的作用,同時也增加了空氣管道的阻力損失,在同樣的工況條件下需要提高管道系統的總壓力
  2. Firstly, simulate flow field of rear smoke channel, plot velocity magnitude and ash concentration distribution in section of entry of heat pipe air preheater, compare with data which were measured in guiyang power station, verify simulation to be reasonable and right. secondly, simulate all kinds of factors which affect flow field ' s uniformity such as length, thickness, location of diffluent board, ash concentration, ash diameter, and so on, find the chiefly factors. thirdly, install guide board in curve channel in rear smoke channel, then simulate its " flow field, plot velocity magnitude and ash concentration distribution

    在此基礎上模擬在冬夏兩季不同情況下,不同流速對熱管空氣預熱器壁面溫度的影響;然後對影響整個流場分佈的各種因素:包括分流板長度、厚度、偏離中心流道位置的偏離度、飛灰濃度、飛灰粒徑等因素進行數值模擬;最後提出在分流煙道轉彎處加裝導流板,並模擬加裝導流板后的流場分佈,得到下級空氣預熱器出口、熱管空氣預熱器進口處的斷面速度場分佈、濃度場分佈,以論證加裝導流板能達到流場均勻化的作用。
  3. Using the program, the thesis studied the status of the chilled water distribution in the system when operating in the practical conditions, and analyzed the performance of the system when adopting different controlling methods of pumps and the chilled water flow in the ahus ( air handling unit ) during the course of converting the constant chilled water flow system to variable chilled water flow system

    利用所編寫的程序研究了冷水系統實時工況下運行時,冷水系統內水量的實際分佈情況;分析了定水量系統改造為變水量系統時,採用不同的水泵控制方案及末端採用不同的水量控制方法時的系統性能。
  4. In this thesis hydraulic experimental studies and theoretical analyses on the vortex - flow drop shaft were conduced and the following results were accomplished : ( 1 ) in the model test some hydraulic characteristics including the shape of air core in the center of the drop shaft, the radial distribution of water flow velocity and the distribution of pressure on the wall of the drop shaft were measured under the condition of high water head above 250m and large discharge above 1400m3 / s. ( 2 ) a kind of computational method for the spiral water flow in the air core region of drop shaft was discussed and applied and the results agree the experimental data well. ( 3 ) the total ratio of energy dissipation in the drop shaft can reach 90 % and the energy dissipation in every region was discussed quantitatively

    本文通過試驗研究與理論分析對旋流式豎井泄洪洞應用於高水頭、大泄流量情況時存在的一些水力學問題進行了研究和探討,取得以下主要成果:一、結合小灣工程導流洞改建,對高水頭( 252m ) 、大泄流量( 1400m ~ 3 s )條件下旋流式豎井中的水流運動特徵進行了比較全面的測量,包括空腔形態、徑向流速分佈及井壁壓強等;二、提出了豎井空腔段螺旋水流水力計算方法,其計算結果與實測值吻合良好;三、利用試驗與計算結果,對旋流式豎井的消能機理進行了探討,對豎井各部分的消能能力有了總體認識;四、對豎井下部消力井的合理井深進行了優化試驗研究,發現消力井合理深度為0 . 9d左右;五、通過試驗研究,歸納出豎井水流總摻氣量估算方法,為導流洞排氣方案的設計提供了參考依據;六、在高水頭、大流量條件下,豎井空腔段下部流速很高,盡管水流螺旋運動引起的離心力可以確保井壁壓強保持正壓,但空化數依然較低,因此豎井的空化空蝕始終是工程界關注的重大問題。
  5. Abstract : the distribution of cooling air which is in the grille - brick of the inner combustion hot air stove has been simulated with three dimension turbulent mathematical model so as to find a method which is used to improve the distribution of cooling air in hot air stove. the influence of differential horizontal plates on the distribution of cooling air is discussed. the results show that original big circle round field of flow in the pillar - cavity is changed into full one - way field of flow and edges gas flow, at the same time, is increased by horizontal plates. there is a different function with horizontal plates and vertical plates. to make the uniform distribution of cooling air in the hot air stove, it is necessary that horizontal plates and vertical plates are used in a combined way

    文摘:應用紊流三維數學模型模擬內燃式熱風爐內冷風在格子磚柱中的分佈,尋求改善其分佈的途徑.討論了加設不同布置的水平導流板對氣流分佈的影響.模擬結果表明,在支柱空腔內加設水平導流板改變了原有大迴旋流場,使迴旋流變成大面積的單向流.通過在支柱空腔內加設水平導流板可以發展邊緣氣流,這恰好與加設豎直導流板的作用相反,水平導流板和豎直導流板的結合使用有望實現冷風在格子磚柱中的均勻分佈
  6. By the numerical simulation, calculate the distribution of velocity ^ temperature and contaminant concentration of air in the room under different modes of air flow organization, and through analysing the outcomes of simulation, draw some conclusions

    對常見的辦公室環境,不同送回風方式下的室內空氣的速度、溫度及污染物濃度的分佈進行模擬計算,並對模擬結果進行分析,得出結論。
  7. A reasonable position of driving nozzle helps to achieve the maximum material flow that also depends on other parameters such as backpressure, properties of conveyed material and driving gas. it is observed that, an increase of convergent section angle is harmful to the pneumatic conveying system, and also influences on the mass flow rate of conveyed material, the distribution of static pressures in injector and the pressure drops of conveying pipe. in addition, within a reasonable scope of air mass rate, increasing the driving jet velocity is more advantageous than enlarging the dimension of driving nozzle

    試驗研究發現,氣體噴嘴位置對氣固噴射器的輸送能力影響最大,氣體噴嘴存在某一最佳位置,而這一最佳位置與背壓、輸送物料特性和輸送風特性相關聯;氣固噴射器的收縮角對其輸送能力、內部靜壓分佈和輸送管阻力特性均有適量影響,收縮角增大對整個輸送系統均不利;在適當的輸送風范圍內,提高氣體噴嘴出口速度比擴大氣體噴嘴尺寸更為有利,但氣體噴嘴出口速度過高會增加氣固噴射器和輸送管內的能量損耗,給輸送帶來不利的影響;系統背壓與氣固噴射器的氣體噴嘴出口速度的選取有關。
  8. The device creates dynamic air supply with stepper motor driving flow distribution plates

    摘要該裝置用步進電動機帶動分流板產生動態風。
  9. Streamline charts are usually drawn for upper air to display the spatial distribution of flow directions at a particular instance of time

    流線流線圖一般慣用於高空,展示某一時刻大氣運動流向的空間分佈。
  10. The porous diffusion type silencer is widely used to reduce the air flow noise because of its small volume and high noise attenuating ability. the out case of the silencer plays a very important role in reducing noise. the effect of the hole ' s shape, diameter and the distance between neighboring holes as well as the matchup between the case and the sound absorbing material tube are investigated experimentally. the relation between the out - flow noise and the gas velocity distribution is carefully studied for two different kinds of matchup between the case and the sound absorbing material tube. some useful results are gotten, which may be valuable to the design of the silencer

    多孔擴散型消聲器由於其體積小、消聲性能高而廣泛應用到排氣噪聲的降低上,其外殼對消聲器的消聲性能具有重要作用.本文對此類消聲器外殼的孔型、孔徑和孔距以及外殼同消聲材料的配合方面進行了細致的實驗研究,特別對外殼與消聲材料的配合與其排放噪聲以及外部流場之間的關系進行了探討,得到了一些有用的結論,對消聲器性能的提高具有一定指導意義。
  11. When the air is fed to cathode of pemfc, the oxygen concentration decreases along the channel because of reaction, and the oxygen distribution is affected by land of the flow plate. so the oxygen distribution is uneven on cathode side and leads to dropping of cell performance

    當pemfc陰極供給空氣時,因氧氣在催化層參與反應被消耗,其濃度沿流道逐漸降低,加之受流道間隔的影響,陰極側氧氣濃度不均勻,這導致電池性能惡化。
  12. Carried out experimental research on conditions of different point heat source ( single, double and many heat sources ), and analyzed the influence of such factors as temperature of air - in, amount and distribution of inlets and outlets, heat emission quantity of heat sources and so on, on distribution of indoor air temperature 、 shape of plume flow 、 heat lamination height 、 ventilation efficiency 、 thermal comfort and so on

    考慮不同點熱源(單、雙及多點熱源)條件下地板送風的系統特性,通過實驗研究,分析了不同送風溫度,送排風口數量及位置,熱源發熱量的大小等因素對室內溫度分佈、羽流流態、熱力分層高度、通風效率、熱舒適性等的影響。
  13. Taking dongzhimen station on beijing metro line 13 as an example, authors of the paper adopt cfd three dimensional simulation and one dimensional network simulation respectively to make a predictive analysis on the smoke distribution and air flow during a fire in accordance with the smoke suppression and exhaust system installed in the public area of the station and in the transit tunnels, and point out that the reliability of the smoke suppression and exhaust system is most important to guarantee the capability of passenger evacuation during a fire

    摘要以北京地鐵13號線東直門站為例,結合車站公共區與區間隧道的防排煙系統設置情況,分別採用cfd三維模擬與一維網路模擬的方法,對火災時煙氣的分佈及氣流流動善進行預測分析,說明防排煙系統的可靠性對于保證火災情況下的安全疏散能力至關重要。
  14. As a result, the air temperature distribution can not meet the design demand, and the air velocity exceeds the demand value in the design code with original scheme, and with the improved scheme of the same air flow and more air outlets, the distributions of temperature and velocity can meet code requirements

    模擬結果顯示,原方案工作區斷面溫度達不到設計要求,風速超出規范要求,改進方案保持總風量不變,增加了送風口數量,其溫度場和速度場都能滿足規范要求。
  15. Asaprofessional 3pl company, the shenmu logistics corporation mainly offers its customers the following service : desining of supplychains, recombinationofthe enterprises logistics, contract - in of the whole material - flow business, international logistics of imports and exports, city distribution, storage, sea and / or air transportation, distribution processing, and international trade business, moreover, the shenmu logistic corporation can offer its customers the value - added services as it possesses both years of experience in the international logistics at numerous ports and the abundant logistics resources and the strong ability to deal with logistics business

    聖之力物流是聖木物流旗下一家專業的第三方物流服務公司,主要面向客戶提供供應鏈規劃與設計,企業物流工作流程重組,物流業務外包,進出口國際物流,城市配送,倉儲,陸海空運輸,流通加工,國際貿易等業務操作,尤其憑借多年來在各港口從事國際物流的營運經驗,擁有強大的物流業務處理能力和豐富的物流資源,能夠為您提供貼身的物流增值服務。
  16. Because the basic principle of variable air volume system is to meet the comfort conditions indoor by varying air flow rates, air distribution is rather important

    由於變風量系統是通過改變送風量來滿足室內舒適要求的系統,所以氣流分佈對于變風量系統是相當重要的。
  17. The study results showed : ( 1 ) the bigger the temperature difference between indoor and outdoor air, the more obvious and more flux of the drop flow ; ( 2 ) the drop flow influenced the room temperature distribution and could even destroy the indoor temperature delamination ; ( 3 ) the prediction values agreed well with the test values, and the modified model could be utilized completely to predict the air - temperature distribution in a chilled wall room with underfloor system

    研究表明室內外溫差越大,壁面下降流越顯著且流量越大;下降流影響房間內溫度分佈且破壞了地板送風房間的溫度分層特性;預測值與實驗值有著良好的一致性,因此該模型可用來預測具有冷卻壁面的地板送風房間溫度分佈。
  18. Developing production and distribution of the high quality automotive spare parts : wheel bearing kits, water pumps, ignition lead sets, steering and suspension parts, filters, belts, air flow meters, automotive bulbs, wiper blades, etc

    該公司廣泛經營汽車配件,包括輪轂軸承小件,水泵,點火線圈,方向機和懸掛件,濾清器,皮帶,車燈,雨刷片,等。
  19. The distribution of the air - flow and temperature in the common heating rooms

    普通採暖房間的氣流及溫度分佈
  20. In this paper, two kinds of cross - flow fan were used during experimental research : the one with bent vane and the one with vertical vane, first of all, the air flow field in the unit was demonstrated by fire sparks and silk thread, also the air flow field in the unit were measured and it ' s state and distribution were got when working with the two kinds of cross - flow fan

    本次研究中裝置採用兩種不同形式的橫流風機:曲板式橫流風機和直板式橫流風機。首創火星法用於演示裝置內氣流狀態,又通過絲線法進一步確定了裝置內氣流流場,並測試了兩種不同形式的橫流風機工作時裝置內的氣流,初步了解了裝置內流場的狀態和分佈情況。
分享友人