  1. The research and development history in the field of auto cascade refrigeration cycle is reviewed. contrast to some traditional cascaded cycles and acrs, a new acr that employs a rectifying column is proposed

    在比較經典復疊循環和前人所研究的自動復疊製冷循環的基礎上,提出了具有精餾裝置的新型自動復疊式製冷循環。
  2. In the condition of same condensation temperature and evaporating temperature, the cop of the basic gax cycle is lower than that of the simplicity cascade cycle, but it is greatly better than the mid - pressure double - effect cascade cycle, on the other hand, the work condition is not as rigor as the simplicity cascade cycle, so the ratio of performance and cost is relatively high

    在相同的冷凝溫度和蒸發溫度下,基本gax循環的性能系數( cop )雖然比單純復疊循環的低,但要遠遠優于中壓雙效復疊循環,而且運行的條件不象單純復疊循環那樣苛刻,故基本gax循環的性價比較高。
  3. The analysis indicates that in the absorbing refrigeration cycle using tfe - tegdme working fluid under the same evaporating temperature and condensation temperature, the performance of the simplicity cascade cycle is the best while the heat burden of the generator is the maximum, the performance of the mid - pressure double - effect cascade cycle is the worst while the heat burden of the generator is higher than the basic gax cycle

    分析結果表明,採用以tfe - tegdme為工質吸收式製冷循環,在同樣的蒸發溫度和冷凝溫度下,單純復疊循環性能最為優越,但發生器的熱負荷也最大;中壓雙效循環性能最差,而且發生器的熱負荷要比基本gax循環大,運行的經濟性差。
  4. Performance study on r600a co2 auto - cascade refrigerating cycle with one - step dephlegmation and two - step dephlegmation

    2一級分凝和二級分凝自復疊製冷循環的性能研究
  5. Study on a new auto - cascade throttle refrigeration cycle with special cryogenic mixture below 60k

    溫區的混合物工質內復疊節流製冷機的研究
  6. A new auto - cascade absorption refrigeration cycle was proposed in this thesis to get low temperatures by utilizing low thermal potential energy based on an overall reviews of innovations in absorption cycles during the past decade

    本文在研究國內外吸收式製冷循環最新發展動態的基礎上,首次提出了一種新型的自行復疊吸收製冷循環,以達到降低吸收製冷機的蒸發溫度,利用低品位熱能來進行深度冷凍的目的,拓寬吸收製冷機的工程應用范圍。
  7. Performance study on auto - cascade absorption refrigeration cycle using r32 r134a dmf as working pairs

    作為工質的自行復疊吸收製冷循環性能分析
  8. Selection of working fluids on a cascade heat pump cycle in application to freeze - drying plant

    一種新型的自動復疊製冷循環
  9. Experimental study of influences of mass fraction of mixtures on auto - cascade refrigeration cycle

    混合工質配比對自動復疊製冷循環影響的試驗研究
  10. Calcul ation and anal ysis of a double - effect cascade absorption refrigeration cycle in middle pressure

    中壓雙效復疊吸收式製冷循環研究
  11. A new auto - cascade throttle refrigeration cycle with special cryogenic mixture for achieving the temperature range around 30k 60k

    溫區混合工質內復疊節流製冷循環及其實驗驗證
  12. Study on an auto - cascade refrigeration cycle adopted with r22 r23 mixture

    復疊熱泵冷凍乾燥系統製冷劑的選擇
  13. The middle pressure double - effect cascade cycle was studied and analyzed. the analyzed result indicates that rectified heat should be reclaimed in such systems

    在中壓雙效復疊吸收式製冷系統的基礎上進行了進一步研究分析,研究提出在風冷條件下,該類系統應回收精餾熱以提高cop 。
  14. In this paper, a new type of absorption refrigeration system - middle pressure double - effect cascade cycle was studied. the aim is to meet gas - fired air conditioning miniaturization and air - cooling. in addition, the system should have high coefficient of performance ( cop )

    本文主要對一種新型吸收式製冷系統一中壓雙效復疊吸收式製冷系統進行了研究,目標主要是滿足直燃型戶式空調系統的小型化、風冷條件,並具有較高的性能系數。
  15. A new auto - cascade refrigerating cycle

    自復疊製冷循環的研究狀況
  16. The thermodynamic analysis and comparison on low temperature natural refrigerant cascade cycle

    帶回熱器的自然工質復疊製冷系統性能分析