dielectric breakdown voltage 中文意思是什麼

dielectric breakdown voltage 解釋
電介質嘩電壓
  • dielectric : adj. 非傳導性的,絕緣的,介電的。n. 電介質,電介體,絕緣體。
  • breakdown : n 1 崩潰,倒塌;破損,損耗;損傷;損壞,故障;失敗,挫折;中斷,停止。2 【航空】下降;【電學】擊...
  • voltage : n. 【電學】電壓,電壓量,伏特數。 the working voltage (電氣的)耐壓限度。
  1. The chemical composition and microstructures of the insulating thin films prepared by different methods were analyzed by x - ray diffraction ( xrd ) and scanning electron micrograph ( sem ) ; other properties such as electric resistance, the breakdown field strength and dielectric properties were evaluated using high resistance meter, voltage resistance meter and precision impedance analyzer respectively

    採用x射線衍射儀( xrd )對表面絕緣薄膜的物相組成進行了分析,掃描電子顯微鏡( sem )對表面絕緣薄膜的微觀結構進行了研究,並用絕緣電阻測試儀、耐壓測試儀和精密阻抗分析儀分別對絕緣膜進行絕緣電阻率、擊穿場強和介電性能的測試。
  2. A series of multi - pulse experiments are performed at breakdown voltage up to 400kv, peak current up to 30ka with an interval of 5ms, which shows spark gap switch could be obtained good insulation recovery in several milliseconds under the condition of water dielectric pulse power modulator with low load

    在擊穿電壓400kv ,峰值電流30ka ,脈寬40ns的工作參數下,採用吹氣的辦法(氣流速度30m / s ) ,使氣體火花開關多脈沖運行間隔達到5ms ,實驗結果與理論估計相符。
  3. The simulation results indicate, deep - trench junction termination with certain width, depth and filling with isolated dielectric can increase the avalanche breakdown voltage of devices to above 95 % of the ideal value

    結果表明:具有一定寬度、深度且填充絕緣介質的深阱結終端結構,阻止了結的橫向擴展,並能將器件的雪崩擊穿電壓提高到理想值的95以上。
  4. Standard test method for dielectric breakdown voltage of insulating liquids using disk electrodes

    用圓盤電極測定絕緣液體介電擊穿電壓的標準試驗方法
  5. Standard test method for dielectric breakdown voltage of insulating oils of petroleum origin using vde electrodes

    用vde電極測量源自石油的絕緣油介電擊穿電壓的標準試驗方法
  6. Standard test method for dielectric breakdown voltage and dielectric strength of insulating gases at commercial power frequencies

    在工業用電頻率時絕緣氣體介電擊穿電壓和介電強度的標準測試方法
  7. Test method for dielectric breakdown voltage and dielectric strength of electrical insulating materials under direct - voltage stress

    直流電壓應力下電氣絕緣材料的介電擊穿電壓和介電強度的試驗方法
  8. Test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials at commercial power frequencies

    固體電絕緣材料在工業電源頻率下的介電擊穿電壓和介電強度的試驗方法
  9. 10. 01 test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials at commercial power frequencies

    固體電絕緣材料在工業用電頻率下的介電擊穿電壓和介電強度的試驗方法
  10. Standard test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials under direct - voltage stress

    在直流電壓作用下固體電絕緣材料的介電擊穿電壓及介電強度的標準試驗方法
  11. Standard test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials at commercial power frequencies

    固體電絕緣材料在商用電源頻率下的介電擊穿電壓和介電強度的標準試驗方法
  12. Then the ideal models ( dielectric isolation structure with high - voltage interconnection and without high - voltage interconnection ) are simulated by a 2d device simulator medici respectively. according to the simulation results, the two models ’ breakdown mechanism is analyzed and compared, and the influence of the isolated trench structure parameter on breakdown - voltage is studied, synchronously

    藉助二維數值模擬軟體medici對理想模型(有、無高壓互連線兩種情況的介質隔離結構)進行模擬,分析其耐壓機理,研究隔離槽參數(槽寬、槽內氧化層厚度)對擊穿電壓的影響。
  13. Firstly, the deep trench dielectric isolation structure is designed, and a mathematical model of the breakdown - voltage is given

    首先設計厚膜soi基深槽介質隔離結構,經過分析得到擊穿電壓的數學模型。
  14. The author ' s main contributions are outlined as following : first, the roles of hot electron and hole in dielectric breakdown of ultra - thin gate oxides have been quantitatively investigated by separately controlling the amounts of hot electron and hot hole injection using substrate hot hole ( shh ) injection method. the changes of threshold voltage have been discussed under different stress conditions

    主要研究結果如下:首先,利用襯底熱空穴( shh )注入技術分別控制注入到超薄柵氧化層中的熱電子和空穴的數量,定量研究了熱電子和空穴注入對超薄柵氧化層擊穿的影響,討論了不同應力條件下的閾值電壓變化。
  15. Standard test method for dielectric breakdown voltage of insulating oils of petroleum origin under impulse conditions

    在脈沖條件下石油成因的絕緣油的電介質擊穿電壓的標準試驗方法
  16. Standard test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials using impulse waves

    用脈沖波法測定固體電絕緣材料的電介質擊穿電壓及抗電強度的標準試驗方法
  17. 10. 02 test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials using impulse waves

    用沖擊波測定電氣固體絕緣材料的電介質擊穿電壓和介電強度的試驗方法
  18. Standard test method for verifying the specified dielectric withstand voltage and determining the dielectric breakdown voltage of a membrane switch

    薄膜開關的規定的介質抗電強度的驗證和介質擊穿電壓測定的標準試驗方法
  19. In this paper, the over voltage induced by re - ignition, rules of breakdown in vacuum contact clearance, factors which influence dielectric strength of clearance and characteristics of re - ignition when vacuum switchgear switch capacitor banks are analyzed. the conclusion is that the breakdown of clearance in vacuum interrupter is the direct cause which inducing re - ignition of vacuum circuit - breaker in capacitor banks ’ switch. particle breakdown is the essential reason to induce breakdown in clearance of vacuum interrupter, although mechanical characteristic of vacuum circuit - breaker is another factor

    本文通過對真空開關投切電容器組重燃過電壓、真空觸頭間隙擊穿機理及影響真空間隙介質強度的因素、真空開關投切電容器組重燃現象特點進行分析研究發現,真空滅弧室斷口的真空間隙擊穿是導致真空斷路器投切電容器組重燃的直接原因,其次是真空斷路器機械性能的影響,而微粒擊穿是導致國產真空滅弧室真空間隙擊穿的根本原因。
分享友人