mutual inductor 中文意思是什麼

mutual inductor 解釋
互感器
  • mutual : adj. 1. 相互的。2. 〈口語〉共有的,共同的。adv. -ly
  • inductor : n. 1. 引導者,授職人。2. 【電學】感應器,感應體,感應物,電感線圈,電感器。3. 手搖磁石發電機。4. 【化學】誘導物。
  1. The mutual inductor of electric current and voltage mutual inductor play an important role in relay protection. prevent from ct differential to protect and miss movement an important subject that the generatrix is protected on the saturation, put forward two electric current pass zero hour linear to spread person who become put into differential to protect in ct in recent years, avoid ct saturation district, can judge the bus bar trouble correctly

    但是在母線區外發生短路故障(特別是故障電流含有大量非周期分量)時, ct會出現飽和現象, ct飽和后,不能正確地傳變一次側電流,從而使二次電流發生嚴重畸變,產生很大的差電流,這樣就容易引起誤動作。防止ct飽和時差動保護誤動作一直是母線保護的一個重要課題,近年來提出的在ct二次電流過零時的線性傳變區投入差動保護,避開ct飽和區,能對母線故障做出正確判斷。
  2. Founded in june 1984 as the first to be designated to manufacture mutual inductors by the former ministry of machine - building and the ministry of electric power, the company became members of the divisions of both china electrial equipment industrial association and national transformer association earliest. the company mainly produces current / voltage mutual inductors below 35kv, which are in comformity with national standards gb1208 - 1997 current mutual inductor and gb1207 - 1997 voltage mutual inductor and adopt international standards iec44 current mutual inductor and iec60044 voltage mutual inductor

    公司成立於1984年6月,系原機械工業部、電力部首批定點互感器生產的專業廠家,是中國電器工業協會分會、全國變壓器分會首批成員單位,公司主要生產35kv及以下的電流、電壓互感器,產品符合國家標準gb1208 - 1997 《電流互感器》 、 gb1207 - 1997 《電壓互感器》 ,採用國際標準iec44 《電流互感器》和iec60044 《電壓互感器》 。
  3. Hez - 1 type digital display self - balancing check meter of mutual inductor

    1型數顯自平衡互感器校驗儀
  4. Thesis this in existing electric capacity, whether it utilize by the ct one mainly reject and mix by suitable partial pressure not low - voltage partial pressure arm not high - handed of cvt electric capacity not insulating, in the middle of and ca n ' t compensate reactor, etc. of voltage transformer, design by sectional mutual inductor that ct combine cvt with, sectional mutual inductance utensil this have electric current mutual inductor and voltage double function of mutual inductor

    本論文在現有電容型絕緣電流互感器和電容式電壓互感器製造技術的基礎上,利用ct的主絕緣電容屏作為cvt的高壓分壓臂,配以合適的低壓分壓器、中間變壓器以及補償電抗器等,設計了由ct和cvt相結合的組合式互感器,該組合式互感器具有電流互感器和電壓互感器的雙重功能。
  5. Standard mutual inductor

    標準互感器
  6. It can be applied for purification of unqualified transformer oil, mutual inductor oil, oil switch oil and capacitor oil as well as low - viscosity lubricating oils

    廣泛應用於電廠電站電力公司冶金石化鐵路等工曠企業,對不合格的變壓器油互感器油油開關油電容器油進行凈化處理。
  7. It can be applied for purification of unqualified transformer oil, mutual inductor oil, oil switch oil and capacitor oil as well as low - viscosity lubricating oils for electric plant, power station, electric company, transformer substation working area, plant, railway, ect

    廣泛適用於電廠電站電力公司變電工區廠礦鐵路等,對不合格變壓器油互感器油油開關油電容器油低粘度潤滑油的凈化再生處理。
  8. Among our country project of transmitting and converting electricity, mutual inductor guarantee power system safe, reliable and economical operation essential equipment

    在我國輸變電工程中,互感器是保證電力系統安全、可靠和經濟運行必不可少的設備。
  9. This thesis analyses the present situation of energy metering in bishan network and some network at home, main factors which lead to inaccuracy of energy metering are dissected and the severity degree are pointed out. the method of enhancing accuracy of metering using modern technique are put forward which including : 1 ) modernization of meter, replacing the induction watthour meter with full electronic watthour meter ; 2 ) put real time change of mutual inductor ratio of transformation into consideration, method on real - time computation are presented. 3 ) using full electronic watthour meter to measure fundamental power and harmonic power separately and discussing idea of billing on harmonic

    這些方法包括: 1 )計量儀表的現代改造,用全電子式電能表代換感應式電能表; 2 )計及互感器變比的實時變化,對互感器的變比進行實時模擬計算,並提出了實時計算的方法; 3 )用全電子式電能表對基波電能與諧波電能分別計量,並討論了對諧波電能計費的觀點。
  10. On the faults of mutual inductor and treatment

    互感器事故及處理
  11. Voltage mutual inductor grounding and its function in transformer substation

    變電站的電壓互感器接地方式及功能
  12. For meet the needs of modern relay protection, these had the above, must study in carrying on design of mutual inductor

    為了適應現代繼電保護的要求,以上所有這些,在進行互感器的設計中都必須加以研究。
  13. Adopt some new material, new technology in design of mutual inductor, apply to mutual inductor to technology of relay protection study

    在互感器的設計中採用了一些新材料、新技術,並且對互感器運用於繼電保護的技術進行了研究。
  14. Fail and turn electric wire into of the distance in 110kv and above voltage high pressure and vltrahigh voltage of grade, the mutual inductor generally adopts the mutual inductor of electric current ( ct ) and voltage mutual inductor ( cvt )

    在110kv及以上電壓等級的高壓和超高壓輸變電線路中,互感器一般採用電流互感器( ct )和電壓互感器( cvt ) 。電流互感器和電壓互感器在繼電保護中起著重要的作用。
  15. And to the electric capacity type voltage mutual inductor, because it compares with electromagnetic type voltage mutual inductor, transient state its bad to respond characteristic, as circuit when making the short circuit two times trouble, the voltage two times delays dropping to zero while needing to pass certain one

    而對于電容式電壓互感器,由於它與電磁式電壓互感器相比,其瞬態響應特性比較差,當線路故障而使二次短路時,二次電壓需經過一定的時延後才能下降到零。
  16. We utilize the mutual inductor to take a sample to the three - phase current, and sample which is enlarged, rectified, filtered, is send into pic single chip microcomputer to deal with. the size of three - phase current on the line is calculated out, which offer the accurate value for the change of controls the equipment state

    利用互感器對三相電流取樣,然後通過放大、整流、濾波,實現交直流轉換,送入pic單片機處理,計算出溫室輸電線上三相電流大小,為控制設備狀態的改變提供精確數值依據。
分享友人