primary capacitor 中文意思是什麼

primary capacitor 解釋
初級電路電容器
  • primary : adj 1 第一的,最初的,初級的;初等的;基本的;基層的。2 主要的,為首的,第一位的。3 原始的,根本...
  • capacitor : n. 【電學】電容器 (=condenser)。 a capacitor microphone 電容傳聲器[話筒,微音器]。
  1. First the paper use the different four network operating condition as the primary given conditions and set the 330 / 220kv transformer tap changer position in the standard position, adding the paralleled capacitor bank sets one by one into the network to change the amount of the input reactive power, thus obtained four sets of the 330kv and 220kv bus voltage and the active and reactive power losses changing curves

    進而研究了在每一確定並聯補償電容器組投入量條件下,隨聯變調壓檔位變化而產生出的一組並聯補償量、母線電壓與損耗的變化曲線。進而選出了隴南電網在四種選定電網運行方式下、有功損耗最小條件下的最優綜合控制組合曲線。
  2. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及電網潮流,總結出了如下規則:隴南電網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯補償電抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變電站母線電壓在理想的范圍內時電網有功損耗最小,從而也提高了電網安全運行水平及供電質量。
  3. On the aspect of errors analysis of hrg, a brief introduction of the close - loop detection theory of hrg is present first. later the expressions of close - loop detection errors are deduced in theory. the impact of stimulating signals, turning speed, outside appended oscillation, the location & area of electrodes, and the current loss in capacitor is considered, and the primary analysis of error compensation is given

    在半球諧振陀螺誤差分析方面,本文從半球諧振陀螺的閉環檢測原理出發,對半球諧振陀螺閉環檢測誤差進行了分析和推導,考慮了激勵信號、轉動速率、外界附加振蕩、電極位置及極板面積和電容傳感器等因素造成的陀螺誤差並對誤差補償進行初步分析。
  4. In the end, the part - magnetic - core pulse transformer is constructed with primary inductance 3. 14 h, second inductance 298. 89 h and coupling coefficient 0. 873. compared with the air - core spiral strip pulse transformer of the same dimension, the coupling coefficient is increased by 13. 4 percent. this transformer is used to charge for water capacitor

    最終研製的部分磁芯帶繞式脈沖變壓器的初級電感為3 . 14 h ,次級電感為298 . 9 h ,次級輸出電壓在635kv以上,耦合系數為0 . 87 ,比相同結構尺寸的帶繞式空芯脈沖變壓器的耦合系數提高了13 . 4 % ,變比提高了20 % ,能量傳輸效率提高44 % 。
分享友人