pseudo-force 中文意思是什麼

pseudo-force 解釋
假力,偽力
  • pseudo : adj. 〈口語〉假,偽,冒充的。
  • force : n 1 力,勢。2 體力,氣力,精力,魄力。3 暴力,壓力;兵力,武力。4 〈pl 〉 部隊,軍隊,兵力。5 勢...
  1. 2. pseudo - static force testing of twelve full - scale connections, including top - seat angle connections, two web flange and top - seat connections, extended - end - plate connections, slit - t steel connections and dog - bone connections are carried out for the first time in our country

    2首次在國內大規模地進行了頂底角鋼連接、帶雙腹板頂底角鋼連接、外伸端板連接以及短t型鋼連接等半剛性連接以及狗骨式剛性連接這五種連接類型共十二個原型試件的擬靜力試驗。
  2. Pseudo - static force testing of 1 : 2 scale models of a steel frame with dog - bone connections is first carried out in china in order to obtain elastic - plastic behavior of dog - bone connections steel frames under cyclic loading as well as to analyze collapse characteristic after structural ultimate strength has lost. the influence of dog - bone connection on the coming order of plastic hinges and failure characteristic of steel frame, and the influence of dog - bone ' s shape and position on the behavior of structure is obtained

    通過試驗考察了狗骨式連接平面鋼框架結構在循環荷載作用下的彈塑性性能;了解狗骨式連接對結構塑性鉸出現的順序以及結構破壞形態的影響;了解節點處與狗骨處應力發展狀況,探討狗骨削弱的形狀和削弱位置對節點性能的影響。
  3. Based on the pseudo - static experimental results of nine abnormal joints, the damage process of abnormal joint is divided into four stages of original crack, entire crack, ultimate state and failure, the effect of axial force ratio, stirrup ratio and height of column section on seismic behavior of abnormal joint are discussed, the conclusion that anti - shear capacity of abnormal joint are studied in entire crack state by studying the minor core of abnormal joint is made, the calculating formula for anti - shear capacity of abnormal joint is proposed with a view to asymmetry in stirrup yield

    摘要根據9個鋼筋混凝土框架異型節點試件的擬靜力試驗結果,指出異型節點受力過程分為初裂、通裂、極限和破壞4個階段;討論了軸壓比、節點核芯配箍率、柱截面高度變化對異型節點抗剪性能的影響;提出應考慮節點核芯區箍筋屈服的不均勻性並在通裂狀態下以「小核芯」為分析單元來研究此類節點抗剪承載力的建議;最終給出了異型節點抗剪承載力的計算公式。
  4. Non - linear shock response calculation of shipboard equipment with displacement restrictor using pseudo - force approach

    利用偽力法計算帶限位器的船舶設備非線性沖擊響應
  5. Taking the bending stiffness, cable sag and cable inclination into consideration, the space vibration control of the cables using the visco - elastic dampers in cable - stayed bridges is investigated by joining the center difference method and the state space strategy. both the maximum modal damping ration and the optimal damper size are obtained, then the practical suggestions are proposed for the design of the dampers. the space nonlinear vibration equations of the cable - damper system are derived, and a new hybrid method for solving the cable - damper system is presented by combing the newmark method and pseudo - force technology

    綜合考慮了拉索抗彎剛度、垂度的影響,研究了粘彈性阻尼器對斜拉橋拉索的空間振動控制,聯合中心差分方法及狀態空間法,得出了拉索麵內、外振動各階模態可能達到的最大阻尼比及相應的最優阻尼器系數,並對斜拉橋拉索的阻尼器設計提出了參考建議:考慮拉索抗彎剛度、垂度及幾何非線性,導出了索-阻尼器系統的空間振動非線性方程組,結合newmark方法及偽力( pseudo - force )方法,創新地提出了求解非線性方程組的雜交方法,根據拉索-阻尼器系統的阻尼特性,在各種荷載作用下,對索-阻尼器系統的非線性瞬態振動響應進行了研究,從系統響應的角度更加直接地驗證了阻尼器的控制效果。
  6. By the pseudo - dynamic test and modal analysis of the frame - bent structure, the paper discussed the seismic behavior, calculation method of initial force, simplified design method and structural features of this type of structure

    綜上所述,通過對該類框排架結構的試驗及理論分析,研究了該體系的抗震性能提出了針對該體系計算方法、設計方法及相應的構造措施。
  7. The earthquake force was ignored during designing midget pump station, while the pseudo - static method just gave approximate calculation to the large and medium pump station ever

    在以往的泵站設計中,對于小型泵站,一般不考慮地震力;對于大中型泵站,即使考慮地震載荷大多都運用擬靜力法,進行大致的近似計算。
  8. Based on the pseudo - static experimental results of nine specimens 1 / 5 - scale specimens and failure characteristic in the structural test, the damage mechanism and the failure of abnormal joints under the shear force is analyzed. the paper discusses the possible affections of stirrup ratio, the changes of beam or column sections and initial eccentricity on carrying capacity of abnormal joints. according to experimental data, the formula for calculation of the shear - bearing capacity of abnormal joints is given

    針對該類框排架結構中通常存在異型節點的實際,在9 (其中邊節點4個、中節點5個)個1 5的偽靜力試件試驗研究及整體結構模型中該類節點破損特點的基礎上,提出了異型中節點和邊節點的破壞機理,針對異型中節點和邊節點的受力特點給出了該類異型節點的抗剪承載力計算公式和節點區的加強構造措施。
  9. Based on the pseudo rigid - body dynamics equivalent model of compliant mechanism, combining with the work done of rigid body mechanism and principle of energy conversion and instantaneous center method, an analysis was carried out on the force transmission effect of compliant mechanism and the expression of relationship of force transmission effect of compliant mechanism and position of mechanism was derived

    摘要基於柔順機構的偽剛體動力學等效模型,結合剛體機構的做功與能量轉換原理以及瞬心法,對柔順機構的傳力效益進行了分析,推導出了柔順機構的力傳遞效益與機構位置關系的表達式。
  10. There are still many problems remain to be solved in these aspects, such as behavior research on the lateral resistant of steel frame and connection etc. in this paper three 1 : 2 - scale steel frame specimens and eight full - scale steel frame connection specimens are tested on their behavior under cycle loading. there are six aspects as below on the problems of steel resident building researched : 1 pseudo - static force testing of eight full - scale connections, including top - seat angle connections, two web flange and top - seat connections and dog - bone connections are carried out for the first time in our country

    本文針對鋼結構住宅體系中亟待解決的若干問題,完成了三榀1 : 2鋼框架模型和八個足尺比例的樑柱連接模型在低周往復荷載作用下的試驗,進行了以下幾個方面的深入研究: 1進行了頂底角鋼連接、帶雙腹板頂底角鋼連接等半剛性連接及狗骨式剛性連接這三種連接類型共八個原型試件的擬靜力試驗。
  11. The result of computational example demonstrated that the practical effect has a better coincidence with the force transmission effect of compliant mechanism analyzed by adopting the pseudo rigid - body method

    算例結果顯示,採用偽剛體法分析的柔順機構傳力效益與實際效果吻合較好。
  12. First, one type of sma - based passive energy dissipation device was developed to utilize pseudo - elastic property. then, according to the characteristic of response of the passive energy dissipation systems, adapting the bilinear restored force model, the mof shear type elastic - plastic time history analysis program is compiled. the vibration - suppressed is verified and vibration control mechanism of sma dampers is studied by time - history analysis

    首先利用sma的超彈性性能,設計了一種新型的耗能減震裝置;其次,結合耗能減震結構的動力反應特點,採用雙線性模型,編制了耗能減震結構串聯多質點體系彈塑性時程分析程序,通過對有控結構和無控結構的地震響應分析比較,檢驗了sma耗能器的被動控制效果,探討了其控制機理。
  13. 4 pseudo - static force testing of 1 : 2 scale models including three steel frame two with semi - rigid connection and one with dog - bone connection are first carried out in china in order to obtain elastic - plastic behavior of semi - rigid connections and dog - bone connections steel frames under cyclic loading as well as to analyze collapse characteristic and the coming order of plastic hinges of the structure with different connections after structural ultimate strength has lost and conditions of stress development in the dog - bone, and the reason of the brittle failure in the rigid connections is obtained

    同時探討了連接形式對鋼框架性能的影響。 4進行了兩榀半剛性連接和一榀狗骨式連接平面鋼框架結構的擬靜力試驗。通過試驗考察了半剛性連接和狗骨式連接平面鋼框架結構在循環荷載作用下的彈塑性性能;了解了不同連接形式的結構在達到極限承載力后的破壞形態和塑性鉸出現的順序。
  14. The pseudo - force method is applied to calculate the compressive strength factor of the kinky propagated crack with the effect of interaction among cracks taken into account

    採用偽面力法計算了考慮相互作用的彎折擴展裂紋應力強度因子,並通過一些簡化得到了顯式的表達式。
  15. Pseudo - static force testing of 1 : 2 scale models including two steel frame with semi - rigid connections is first carried out in china in order to obtain elastic - plastic behavior of semi - rigid connections steel frames under cyclic loading as well as to analyze collapse characteristic after structural ultimate strength has lost and the coming order of plastic hinges

    通過試驗考察了半剛性連接平面鋼框架結構在循環荷載作用下的彈塑性性能;了解結構在喪失極限承載力后的破壞形態和塑性鉸出現的順序;利用所編程序計算了其中一個框架的受力性能。
  16. Secondly, the push - over analysis is for the three - dimensional solid element model and the plane beam element model. the total shearing force - lateral displacement curve can be obtained from it. and then the total shearing force - lateral displacement curve is converted to pseudo acceleration - period curve and some comparisons are made between the pseudo acceleration - period curve and design response spectrum

    然後,建立了有限元三維實體單元模型及平面桿單元模型,對其進行了push - over分析,並將所得的底部剪力一頂點位移曲線轉化為擬加速度一周期曲線,與規范反應譜進行對比,以此評定該體系的抗震能力。
分享友人