放大器研究所 的英文怎麼說

中文拼音 [fàngyánjiūsuǒ]
放大器研究所 英文
amplifier research
  • : releaseset freelet go
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • : 研同 「硯」
  • : Ⅰ動詞(仔細推求; 追查) study carefully; go into; investigate Ⅱ副詞[書面語] (到底; 究竟) actually; really; after all
  • 放大器 : amplifier; pantograph; lawnmower; enlarger; magnifier
  • 放大 : amplify; magnify; boost; enlarge; blow up; gain; amplification; enhancement; multiplication; magn...
  • 研究所 : a graduate school
  • 研究 : 1. (探求) study; research 2. (考慮或商討) consider; discuss; deliberate
  1. This paper starts the research of the liquid floated pendulous accelerometer testing system according to the engineering. at first, this paper gives the brief introduction of the history and present status of accelerometer and its testing technology, the working principium and math model of the liquid floated pendu - lous accelerometer, and then, decides the binary width pulse force retrim loop as the design proposal of testing system, researches the transfer function of every part in the system emphasizly, analyses the stability of the whole accelerometer testing system from the angle of control theoretics by the open loop transfer function of system, and designed the correcting net, analyses the basal problems such as resolution, sampling restraint, precision and so on, designs the hardware testing circuits such as preamplification, band - pass filter, alternating amplifier, phase sensitive demodulatorn, pulse - width modulation, frequency scale circuit, moment current generator. finally, using the graphics program language labv - iew which is designed for testing field especially by ni accomplishes the solfware design of testing system, realized the testing functions

    首先對加速度計及其測試技術的發展歷史和現狀,液浮擺式加速度計的工作原理和數學模型等作了簡要的介紹,然後確定了以二元調寬脈沖再平衡測試迴路為設計方案,並從控制理論的角度進行了分析,著重了系統中各部分的傳遞函數,利用系統開環傳遞函數分析了系統的穩定性,同時設計了系統的校正網路;分析了二元調寬脈沖再平衡測試迴路的解析度、采樣約束以及測試精度等基本問題,並按照系統分析的結果設計了包括前置、帶通濾波、交流、相敏解調、脈寬調制、頻標電路以及力矩電流發生等測試系統各部分硬體電路,驗證了電路的正確性,最後按照測試系統的要求,採用了美國ni公司專為測試領域開發的虛擬儀工具? ? labview作為測試軟體開發工具,利用該圖形化編程語言完成了測試系統軟體部分的設計,實現了測試功能。
  2. Objective : to establish a rat model of orthotopic gastric isotransplantation by using microsurgical techniques. methods : 70 sd rats were used in our experiment and 35 gastric trasplantations were carried out. in the donor ' s operation : after the spleen was resected and the proper liver artery was ligated, the stomach was perfused through the abdominal aorta. then the stomach was resected with its peripheral blood vessels including celiac trunk and the portal vein, etc. in the recipient operation : after the stomach and the spleen were reseeted, the implantation was performed by the following sequence : the end - to - side anastomosis between the portal veins. the end - to - end anastomosis between the celiac trunk and the left gastric artery. open the blood flow to observe the effect of the blood supply of the stomach. the end - to - end anastomosis between the duodenum. the end - to - end anastomosis between the cardiac and the esophagus. results : 35transplantations were carried out in which the operation success rate in the last 20 cases was 80 ( 16 / 20 ). the average operation time was 2. 35 h. the longest survival time was over three months. conclusions : the model of orthotopic gastric transplantation in rat was successfully established. it could be used to study the transplanted stomach in the abdominal multiviseeral transplantation and the reconstruction after the total gastrectomy

    目的應用顯微外科技術,建立鼠原位異體胃移植模型.方法70隻sd鼠,行35例次的胃移值手術.供體手術,先切除脾臟,經腹主動脈行原位胃冷灌洗.將胃及其屬血管,包括腹腔乾和門靜脈乾等一併切取.受體手術,先切除胃和脾臟,分別行供、受體間門靜脈的端側吻合,供體腹腔干與受體胃左動脈的端端吻合,然後開血流.再行供體和受體十二指腸間端端吻合,賁門與食管端端吻合.結果在施行的35例手術,后20例中有16例成功,成功率為80 .最長存活者達3個月.結論成功地建立了鼠原位異體胃移植類型.該模型可用於腹部多臟移植中移植胃的相關及全胃切除術後代胃的
  3. Relative to euro, euro emission regulations add the test of emission in 40s after cold - start. in order to meet the more strict emission regulations, the key question is how to make the three - way catalytic converter to light - off and increase the conversion efficiency. so it is necessary to do a numerical simulation on light - off characteristic and conversion efficiency of three - way catalytic converter in cold - start stage

    歐排標準相對于歐排標準增加了冷起動頭40s的有害排物測試,為滿足更嚴格的排法規,如何使三效催化轉化盡快起燃,提高對排氣的轉化效率是關鍵問題,因此對三效催化轉化在發動機冷起動階段的起燃特性和轉化效率進行數值模擬趨。
  4. The results indicate that the soliton amplitude slightly decreases in the border between the single - mode fiber ( smf ) and the dispersion compensation fiber ( dcf ), but and its shape remains unchanged, while its signal amplitude is amplified when it passes an amplifier and its shape automatically restored

    表明,在普通光纖與色散補償光纖的交界處,孤波的幅度有降低,但其形狀保持不變;光孤子通過后其幅度得到,其形狀將自動得到恢復。
  5. In practical application, the m10 180 bolts, which are installed in the head cover of the torque divider of ts5560 special automobile, sometimes fracture all of a sudden. according to the tests of acceleration, stress and strain, and the exciting test, it is resonance vibration that leads to the compound - bending fatigue fracture of the bolts. the exciting force caused by drive system, transmitted through the torque divider, produces a 1000 - 1500hz cyclical excitation at the junction of the bolts and head cover, which causes the first order bending resonance vibration of the bolts

    通過加速度、應力應變測試實驗和激振試驗的,發現ts5560特種車分動取力氣缸端蓋m10 180螺栓斷裂問題是由於共振引起的雙向彎曲疲勞斷裂:傳動系統工作產生的激勵,經過分動結構的傳遞(特別是分動一階扭轉模態的) ,在螺栓的連接處產生1000 1500hz的振動激勵,其導致螺栓一階彎曲共振,在螺栓一階彎曲模態的阻尼比較小的情況下,使得螺栓產生較的共振響應,導致螺紋處的彎曲動應力較,疲勞壽命較低。
  6. Abstract : by using the pulse - sequence model , the inverse problem of amplification of broad - spectral - bandwidth laser pulse has been studied , i. e. , to find the initial input temporal pulse profile , spatial profile , spectral distribution and fluence from the required output temporal , spatial pulse profile , spectral distribution and fluence as well as the given amplifier parameters

    文摘:採用脈沖分割模型,了寬頻帶激光脈沖的逆問題,即由要求的輸出激光脈沖時間、空間波形、光譜分佈和能量密度,並給定參數情況下,求輸入激光脈沖時間波形、空間、光譜分佈。
  7. Fatigue test indicates that strain multiplier have not been damaged for fatigue in the service life of fatigue life gage, fatigue response of fatigue life gage can be derived from the strain amplitude equal to specimen strain multiplied by amplification coefficient of strain multiplier

    疲勞實驗表明,在疲勞壽命計工作壽命內,應變倍增無疲勞破壞情況,疲勞壽命計疲勞響應可由靜載標定倍數乘試件表面應變后對應的等幅應變值得到。
  8. The paper primarily researches a kind of nonlinearity of fiber - the effect of srs ( stimulated raman scattering ) to wdm ( wavelength division multiplexing ) system and the gain and noise properties of fiber raman amplification exploited with srs

    本文主要了光纖中的一種非線性效應?受激喇曼散射對數字波分復用傳輸系統性能的影響,以及利用它開發的光纖喇曼的增益和噪聲特性。
  9. A ppt test set has been made, and a measurement system of ppt ' s electric properties ( voltage and discharge current ), isp and thrust has been established. measurement of electric properties of the ppt and its isp, thrust has been carried out

    通過量的工作,製造了脈沖等離子體推力樣機,設計並建立了地面真空環境下對于樣機的電參數(電壓、電流變化)以及推力、比沖的測量環境,並對製的樣機進行了電參數和比沖及推力的測量。
  10. This paper has analyzed the characteristics of near - field electromagnetic fields and the measurement principle of magnetic - field sensor, and designed probe, amplifier unit and compensator according to measurement needs. finally, based on the electromagnetic pulse simulator in the lab, a set of experiments have been done on the designed magnetic fields measurement system and analyzed the error of the measurement system

    文中分析了近場電磁場分佈的特點;了磁場探頭的測量原理;根據實際測量需要製作了磁場探頭、設計了信號單元和用於補償電纜信號衰減的補償;最後利用實驗室的電磁脈沖模擬設計的磁場測量系統進行了一系列實驗,分析了系統的測量誤差。
  11. The erbium doped fiber amplifier has been tested in the direct amplifier station of institute of fujian telecommunications for the first time in china. the experiment was very successful

    並將製成功的摻鉺光纖首次運用到合作單位福建郵電科學的光纖直機上進行線路傳輸實驗,實驗十分成功。
分享友人