標稱相對電平 的英文怎麼說

中文拼音 [biāochènxiāngduìdiànpíng]
標稱相對電平 英文
nominal relative level
  • : Ⅰ名詞1 [書面語] (樹梢) treetop; the tip of a tree2 (枝節或表面) symptom; outside appearance; ...
  • : 稱動詞(適合; 相當) fit; match; suit
  • : 相Ⅰ名詞1 (相貌; 外貌) looks; appearance 2 (坐、立等的姿態) bearing; posture 3 [物理學] (相位...
  • : Ⅰ動詞1 (回答) answer; reply 2 (對待; 對付) treat; cope with; counter 3 (朝; 向; 面對) be tr...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ形容詞1 (沒有高低凹凸 不頃斜) flat; level; even; smooth 2 (高度相同; 不相上下) on the same l...
  • 相對 : 1. (面對面) opposite; face to face 2. (非絕對的) relative 3. (比較的) relatively; comparatively
  1. It has been verified by simulation tests that the symmetric short - circuit protection can not only avoid the starting current but also achieve higher sensibility ; unbalance protection can distinguish unbalance short - circuit and loss of phase. the operation parameters of other protective functions has all reached the design requirements

    短路保護既能躲過起動流,又有較高的靈敏度;不衡保護,能準確區分不短路和斷故障;其它保護功能的動作指均達到了設計要求。
  2. It compares and analyses the equipment test voltage emendated to standard atmosphere conditions with the equipment nominal withstanding voltage. and then it concluded that : the emendation value educed by " humidity ratio " integrated emendation method is basically equal or close to the equipment nominal withstanding voltage ; but the values by two traditional emendation methods are mostly higher. it also proves that, " humidity ratio " integrated emendation method is more perfect than any other methods, and it can reflect the influence degree of atmospheric parameters on electrical equipment outer insulation discharge voltage actually

    文中選擇「比濕」綜合校正法和兩種傳統校正法,分別西高所為羊八井、拉薩、羊湖110kv變所設備所做的人工氣候室模擬試驗數據及雲南中試所做的zs - 110工頻放壓試驗數據進行校正計算,將試驗壓的校正值與試驗設備的耐受壓水進行比較分析;認為: 「比濕」綜合校正法的校正值與設備耐受壓水基本等或接近,而兩傳統校正法的校正值大多高於設備耐受壓水;進一步證明, 「比濕」綜合校正法是目前諸多校正法中較為完善的,能真實地反映大氣參數氣設備外絕緣放壓的影響程度的校正法,在高海拔力工程設計中應推廣應用。
  3. Firstly, the basic character of the remote filed eddy current is simulated and analyzed in case of two - dimension axial symmetry which approves the existence of remote filed eddy current phenomenon ; the full circumferential defect model is investigated to approve the feasibility of using the rfec techniques to detect the position and depth of defect ; the pit corrosion 、 circumferential and axial crack models are simulated, and the defect character based on voltage plane polar plot and the changes of phase and amplitude are analyzed to supply the standard for defect reconfiguration

    首先,在二維軸情況下模擬與分析了遠場渦流的基本特性,證實了遠場渦流現象的存在;全周向缺陷的遠場渦流檢測進行了詳細研究,證實了遠場渦流檢測缺陷位置和深度的可行性;點狀腐蝕、軸向與周向裂紋三種非軸缺陷進行三維有限元模擬,利用位差和幅值變化曲線與面極坐缺陷特徵進行分析,為缺陷形狀重構提供了依據。
分享友人