氣冷式減熱器 的英文怎麼說
中文拼音 [qìlěngshìjiǎnrèqì]
氣冷式減熱器
英文
air-cooled desuperheater- 氣 : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
- 冷 : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
- 式 : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
- 器 : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
-
Heat pipe air pre - heater is adopted to recover gas heat to heat up cold air for burning, reducing flue gas temperature and increasing heat efficiency of injecting steam boiler
採用熱管式空氣預熱器,利用排煙熱量加熱冷空氣,降低了煙氣溫度,減少排煙熱損失,提高注汽爐熱效率。The corrugated tank made of high quality cold - rolled - steel sheet manufactured with special production line. it can swell up or shrink compensating the oil from atmosphere. protect and delay the oil and the insulation against degradation, therefore enhance the operation reliability and free of maintenance under normal conditions
全密封變壓器與普通油浸式變壓器相比,取消了儲油櫃,由波紋油箱的波翅代替油管作為冷卻散熱元件,波紋油箱由優質冷軋薄鋼板在專用生產線上製造,波翅可以隨變壓器油體積的脹縮而脹縮,從而使變壓器內部與大氣隔絕,防止和減緩油層的劣化和絕緣受潮,增強運行可靠性,正常運行免維護。The main products includes various steam and electric heating reaction vessel, conduction oil, outer coil reaction vessel, polyester and resin completed equipments, vacuum reducing concentration tank, methanol and ethanol recovery tower, various corrugated stuffing, high effective membrane evaporator, new - type centrifugal drag membrane evaporator, vacuum rake dryer, condensing drum cut - off machine, shell - and - tube condenser,
本廠主要產品有各類蒸氣電加熱反應鍋,導熱油外盤管反應鍋,聚脂樹脂全套設備,真空減壓濃縮罐,甲醇乙醇回收塔,各類波紋填料,高效薄膜蒸發器,新型離心刮板式薄膜蒸發器,真空耙式乾燥機,冷凝滾筒切片機,列管式冷凝器,螺旋板式換熱器,外循環蒸發器,鋁制槽車貯罐,乳化設備,高速剪切分散機,種子罐,發酵罐,多功能提取罐,並承接各類非標設備。The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure
建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為蒸餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;凝結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure
文摘:建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為蒸餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴散規律進行了試驗,得出分離式熱管有一最佳充液率,其值為45 %左右;凝結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制Evaporative cooling can keep a low and uniform wall temperature. it can reduce the volume, the weight of the electrical equipments. meanwhile, it is safe and reliable even in short - time emergency overloads, so this cooling method really shows great promise on the application of large electrical equipment
採用此種冷卻方式的大型變壓器等電氣設備換熱效率高、能耗少;發熱表面溫度均勻;結構緊湊、製造所需材料減少、製造成本下降;壽命延長;重量減輕、體積減小;安全可靠。分享友人