污染測量儀 的英文怎麼說

中文拼音 [rǎnliáng]
污染測量儀 英文
contamination meter
  • : Ⅰ名詞(臟水; 臟物) slops; sewage; dirt; filth Ⅱ動詞(弄臟) defile; dirty; smear Ⅲ形容詞1 (臟)...
  • : Ⅰ動詞1 (用染料著色)dye 2 (感染) catch [contract] (a disease) 3 (沾染) acquire (a bad hab...
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 名詞1 (人的外表) appearance; bearing 2 (禮節; 儀式) ceremony; rite 3 (禮物)present; gift 4 ...
  • 污染 : pollute; contaminate
  • 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
  1. Using mass flux controller ( mfc ), gas regulation system achieved accurate mix of two kinds of gases, steel bottle gas ( some compressed gas ) and zero air ( pure air ). for the sake of data transmission between dynamic air regulator and other equipments in the monitoring air quality system, normal digital interface ( rs - 232c ) make correlative role of communication interface so that automatic survey could be achieved

    器採用國際先進的自動控制配氣原理,採用精密質控制器( mfc )來控制鋼瓶氣(某種壓縮氣體)與零空氣(純凈無的空氣)的混合比來得到精確濃度的校準氣體,以便於對各種氣體監進行高精度校準。
  2. This paper describes mainly system functions, measuring methods, circuit design, software program and errors analysis of a new type of measuring instrument. this instrument can measure and monitor electric parameters in single - phase circuits, three - phase ( three - wire or four - wire ) circuits. this system can be applied to electric devices and power plants, transformer substations with harmonic pollution. it can measure current, voltage, power, energy, frequence, power factor etc. it also can detect load quality, phase sequence, alarm, display and print results, as well as detect and dispose negative power

    器適用於含有諧波情況下的機電設備現場、發電廠、供電局、企業變電所現場,可用來電流、電壓、有功功率、無功功率、視在功率、有功電能、無功電能、視在電能以及頻率和功率因數等電參數,並具有負載性質(感性、容性)判別,正、逆相序判別指示功能;超限報警功能;列印記錄功能和負功檢及處理功能。
  3. Method for the determination of an acid gas pollution index expressed as so2 equivalent using a continuous sampling automatic sequential analyser

    用連續取樣自動順序分析定酸性氣體指數用2當值表示的檢方法
  4. Development of portable tritium surface contamination survey meter

    便攜式氚表面污染測量儀的研製
  5. Portable radiation surface contamination meters and monitors

    便攜式放射性表面器和監
  6. Reference sources for the calibration of surface contamination monitors part 2 : electrons of energy less than 0. 15mev and photons of energy less than 1. 5mev

    用於校準表面的參考源第二部分:能低於0 . 15mev的電子和能低於1 . 5mev的光子
  7. Reference sources for the calibration of surface contamination monitors. part 2 : electrons of energy less than 0, 15 mev and photons of energy less than 1, 5 mev

    表面校準的參考輻射源.第2部分:能低於0 . 15mev的電子和能低於1 . 5mev的光子
  8. Because of the influences of the turbidity, ph of raw water, current, temperature and the pollutions of raw water, the process of coagulant dosage is a very complex reaction. to find out the automation of coagulant dosage and reduce the cost of the coagulant, many domestic and international scientific research organizations make research into the theory and mechanism of automation of coagulant dosage, such as the streaming current control method ( scd ), the emulation experimenting method in spot, mathematics model, flocculation control device ( fcd )

    由於受到原水濁度、 ph值、配水流、原水溫度和其他水質的影響,投藥絮凝過程是一個非常復雜的反應過程,為實現投藥系統的自動化和降低混凝劑耗率,國內外相當多的科研機構和院校在進行投藥機理和自動化處理的研究,主要有流動電流法( scd ) 、現場模擬實驗法、數學模型、顯示絮凝控製法( fcd法)等自動投藥方式的研究和實驗。
  9. Without lens, the scattering pattern caused by the dust particles contamination on the lens surface was avoided

    另外,由於該不使用透鏡,還避免了由於透鏡受而引起的雜質衍射對的干擾。
  10. A multi - parameter intelligent environmental monitora feasible environmental monitoring terminal system of the updated and advanced international technology, has been developed under the environmental protection objectives of the total amount control of pollutant discharge and on the basis of the present techniques as to the environmental monitor and supervision in our country

    根據我國環境保護的目標?實施物排放總控制,從我國環境監和環境監理現狀出發,開發了既切合我國國情又具有二十世紀末國際先進水平的環境終端系統一多參數智能環境監
  11. Calibration for alpha, beta surface contamination meters and monitors

    .表面污染測量儀與監的校準
  12. Alpha, beta and alpha - beta surface contamination meters and monitors

    Alpha beta和alpha - beta表面污染測量儀與監
  13. Radioactive aerosol contamination meters and monitors

    放射性氣溶膠污染測量儀和監視
  14. Surface contamination meters and monitors for alpha -, beta - and gamma - radiation - part 10 : installed personnel surface contamination monitoring assemblies for alpha and beta radiation iec 61098 : 1992, modified

    ,和射線表面污染測量儀和監視.第10部分:和
  15. This updated universal monitor is the compound of a flow meter, a pollution treatment facility operation recorder, a pollutant indicators " collector and a adapter of general monitors, which is characteristic of intellectualization, networking and functional modularization with the modern techniques relevant to microprocessor, data communication and control network

    它是採用先進的微處理器、數據通信技術口控制網路技術,實現了智能化、網路化、功能模塊化,並集監表中的流計、處理設施運行記錄指標數據採集、適配器於一體的新型環境監通用表。
  16. Air quality. ambient air. instruction handbook for the calibration of atmospheric polluant analyzers and samplers. sampling. measuring station and gas flow rates

    空氣質.環境空氣.大氣分析和樣品器校準的說明手冊.采樣站和氣流速
  17. We detect the degree of oil pollution on line. at the same time we analyzed the eroded and polluted procedure of the wall of steel piping and found the most effective chemical rinsing technics of degreasing, pickling, passive and desiccation procedure

    該裝置全方位控制源,合理有效地控制沖洗液的溫度、壓力、流,在檢方法上使用了油度檢在線檢。同時分析鋼管內表面的腐蝕和過程,找到了脫脂、酸洗、鈍化及乾燥處理這一最有效的化學清洗工藝。
分享友人