滿負載條件 的英文怎麼說

中文拼音 [mǎnzǎitiáojiàn]
滿負載條件 英文
full-load conditions
  • 滿 : Ⅰ形容詞1 (全部充實; 達到容量的極點) full; filled; packed 2 (滿足) satisfied; contented; conte...
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 載Ⅰ名詞(年) year : 一年半載 six to twelve months; six months to a year; 三年五載 three to five ...
  • : Ⅰ名詞1 (細長的樹枝) twig 2 (條子) slip; strip 3 (分項目的) item; article 4 (層次; 秩序; 條...
  • : Ⅰ量詞(用於個體事物) piece; article; item Ⅱ名詞1. (指可以一一計算的事物) 2. (文件) letter; correspondence; paper; document
  • 負載 : [電學] load
  • 條件 : 1. (客觀的因素) condition; term; factor 2. (提出的要求) requirement; prerequisite; qualification
  1. The typical ground current ( quiescent current ) is 1ma at full load, 60 a with no load and, and less than 1 a in shutdown mode

    滿負載條件下,靜態電流為1ma ;在空情況下,靜態電流為60 a ;在關斷情況下,靜態電流小於1 a 。
  2. ( 4 ) the experiment of asymmetrical half bridge converter design and the result of it base of the above analysis, the dc / dc converter is designed, it is proved that asymmetrical half bridge can realize zero voltage switching when it satisfies the condition of load current and deadtime by the experiment

    ( 4 )不對稱半橋的實驗電路設計及實驗結果基於前面的分析,設計了一個不對稱半橋dc dc變換器的實驗電路,進行了實驗研究,實驗結果證實了在滿足死區和電流兩個時,不對稱半橋可以實現零電壓開關。
  3. The further research in port engineering pile foundation is considered to be important of such as behavior and bearing capacity of laterally loaded single piles and pile groups, and the functional mode of wharf foundation pile under flood tide torrent, and load - deflection curve, and negative skin friction along the pile, et al. the bearing capacity and the negative skin friction of port engineering piles are analyzed, to satisfy port engineering development demand better

    在港口樁基工程領域,港口工程水平承(群)樁的工作性狀以及承力計算方法,漲潮急流等動態荷作用下碼頭基樁的受力性狀,樁的作用荷與變位趨勢關系、樁的摩擦等問題都要求作進一步的研究。本文致力於以港口工程樁基為主要研究對象,對港口工程(群)樁基水平承力和摩擦力進行研究,以更好地滿足港口工程建設需要。
  4. Repetitive control is used to reduce voltage distortion under abrupt load variation or nonlinear loads and attain good quality of the voltage waveform ; current loop is designed to quicken the dynamic response and strengthen the ability of the inverter control

    重復控制可以抑制逆變電源在變化嚴重(空加到滿)或者非線性下的輸出電壓畸變,保證輸出波形的質量;電流環用以改善輸出波形的動態響應特性,提高逆變控制的能力。
  5. According to the characteristic of nine - area diagram of substation vol / var coordinated control, this system gives the defination of fuzzy sets and the degree of membership of input / output variables, and designs corresponding control rules. the results of simulation demonstrate the system can satisfy the constrains of the day - adjusting times of the switching of on - load transformer and paralleled compensation capacitors, and ensure voltage quality, reactive power basical balance. considering the var requirement in different load time period and the control demand in load saltation, a improved control scheme is provided. the results of simulation show the improved scheme can meet the demand of vol / var in different load time period, protect the wrong operation when either voltage or reactive power appears saltation, and decrease the times of regulation of the switching of on - load transformer and paralleled compensation capacitors finally, a background software module of substation vol / var coordinated control is designed, based on the supervisory control and data acquisition system of substation

    模擬結果證明該系統能在各種下確保電壓合格和無功基本平衡,且能滿足變電站對有調壓變壓器分接頭日調節次數和並聯補償電容器組的日投切次數的限制。通過考慮不同荷時段對無功功率的需求和荷突變情況下的控制要求,對上述模糊控制策略進行了改進,模擬結果證明改進后的控制策略能滿足不同荷時段對電壓和無功的要求、抑制電壓或無功突變情況下的誤動作,且有效地減少了有調壓變壓器分接頭和並聯補償電容器組的調節次數。最後基於變電站scada系統設計了一后臺電壓無功綜合控制軟體模塊。
  6. The second, the realization of the zvs has no concerned with the attribute of load. with the load of light or full, even the resistance or inductor load, the chopper can ensure that the main - switches will realize the zvs switching

    其次,實現零電壓軟開關的的性質和程度沒有關系,無論是電阻性還是大電感,無論是輕還是滿,都可以實現功率器的零電壓開通和關斷。
分享友人