  1. Based on many references form civil and abroad, the author mainly studies the measurment theory and method for flux, raising height, axial power and rotational velocity. avoiding many complicated and intermediate courses for power wastage analysis, introduces the electric measurement and using efficiency curve of motor in measureing axial power, and satisfies the automatization of the device. the paper also provides a new method, inductive winding, in measuring rotational velocity of electromotor, supplys limitations of other method in measuring rotational velocity of electromotor in water, and meet practical needs in developing diving electric pump for corporation

    作者在參閱大量國內外有關文獻,著重探討了水泵流量、揚程、軸功率、轉速的測試原理和測試方法,提出了採用測法並結合機效率特性曲線測量水泵軸功率,從而避免了分析法中大量復雜的中間過程,滿足了試驗裝置的自動化測量要求;採用磁感應線圈法測量機轉速,彌補了其它轉速測量方法對水下機測試的局限性,適應了萊恩公司開發潛水泵的實際需要。
  2. By compared with the simulation results and the experiment results, we come to the conclusions that : ( 1 ) circuit with assistant network can widen soft - switching extent in lagging arm, reduces duty - cycle loss on the secondary, diminishes switching dissipation of inverter spot - welding power source. ( 2 ) the range of resonant capacitor, the important factor to soft - switching process, not only affects zero - voltage turn - off of power switches, but also affects the range of zero - voltage turn - on of power switches. so resonant capacitors must be considered according to many aspects ; ( 3 ) it easily fulfils soft - switching condition in lagging arm as leakage inductance of power transformer increases, but bigger leakage inductance of power transformer increases opening dissipation of transformer and decreases efficiency of soft - switching inverter power source

    通過模擬結果與軟開關點焊逆變器試驗結果的對比分析,得到了如下主要結論:採用輔助網路可以完全拓寬全橋軟開關逆變器的滯后橋臂軟開關范圍,減小了次級占空比丟失,降低了逆變阻點焊源的開關;諧振容是影響軟開關工作狀態的重要因素,其大小不僅影響開關管的零壓關斷,同時也影響開關管的零壓開通范圍,因此,諧振容應該綜合考慮;功率變壓器感越大,越容易滿足滯后橋臂的軟開關條件,但是大的感也使變壓器的通態增加,降低了軟開關逆變器的效率。
  3. In order to obtain ideal efficiency, the rf mosfet sd2918 [ 4 ] is used. also, the dead - time is inserted between the drive signals of mosfets, which is effective for reducing the shot - through loss and drain - source capacitor cds loss

    為了獲得理想的放大效率,採用射頻場效應管sd2918 [ 4 ] ;同時,在兩驅動信號之間引入dead - time ,減小mosfet的串通以及mosfet的源輸出容cds
  4. Research and summary for stray losses and overheating control on metal parts caused by leakage flux of transformer has been given by author in this article through a lot of tests on site, meanwhile, the analysis has been given by electrical - magnetic theory also

    本文運用變壓器磁學理論,通過進行大量探索性試驗,研究並總結出如何控制由於變壓器磁引起的附加以及金屬構件中的溫升。
  5. This paper, according to the characteristic and requests of measurement for the medium loss of electric capacitive equipment and the resistive weight of moa leak current in a power substation, according to the on - line monitoring principle and implementing scheme of electric equipment in substation relying mainly on the means through the software analysis, finish the design and the fabrication of monitoring system hardware and software, and then empolder the on - line monitoring equipment fitting for the 220kv substation of dazhuling in chongqing, have finished the installation, debugging and the data analyzing of the running device

    本文針對變容性設備介質和moa泄流阻性分量測量的特點和要求,按照以軟體分析為主的變氣設備絕緣在線監測的原理和實施方案,完成了監測系統硬體、軟體的設計、製作並開發了適合於重慶大竹林220kv變氣設備絕緣的在線監測裝置,完成了裝置的安裝、調試和運行的數據分析。