  1. This article aims at the boiler ' s problems in operation : 1 ) under nominal load, the smoke temperature at the outlet of hearth reaches 1200, far more exceeds 1050 the original designed temperature. this will always result in slag inside boiler and the temperature of overheater ' s pipe superheat, so that boiler cannot take nominal load and all these influence boiler ' s nomal operation heavily, 2 ) this article also studied the reason why the assistant oil becoming necessary when coal changes. during the nomal operation, many factors ( makeup of combustor and its disposal, smirch and encrust of water wall, excessive air coefficient, temperature of primary air, coal type and density of coal dust ) can deviate the designed working conditions, then affect the boiler ' s nomal operation

    本文針對該鍋爐在實際運行中存在的問題:在額定負荷下,爐膛出口超溫、低溫段過熱器前溫高達936 ,遠遠超過815的設值;噴燃器四周水冷壁結焦嚴重,過熱器管壁溫超標,無法帶上額定負荷;甚至有時因燃煤質量的變化,必須投油助燃的嚴重情況進行了分析研究。在實際生產過程中,燃燒器的結構、布置,水冷壁的粘污、結垢,過剩空系數、一次風溫、煤種及其變化等許多因素都會偏離鍋爐的設工況,從而影響爐內的傳熱和燃燒,造成爐膛出口超溫、水冷壁結渣等問題。
  2. With analyzing of the case study and based on simulating and analyzing quantitatively, this article, considering the goal of the performance - based fire - protection design is protecting occupants from being injured and keeping buildings from being damaged, thought that fire compartmentation of a large building of saling books can be divided according to their saling malls and fire compartmentation in the saling mall can be separated by the fire - proof screen. on the evacuation design, the quantity of safety exits around these buildings and the evacuation width should be increased if possible and the safety exit number, exit width and evacuation distance can be determined according to the simulating results on smoke layer temperature and height, concentration of co2 and co, occupants evacuation time and visibility. on the means of preventing and discharging smoke, the most proper measure should be determined according to their geometrical characteristics and the natural means of discharging smoke is feasible to the large building of saling books. based on analyzing of smoke

    通過對案例分析研究,本文認為大型書城建築性能化防火設研究的最終目的是保證人員生命安全和保證建築結構安全,在模擬算和量化分析的基礎上,大型書城的防火分區可以將中庭連通的書城區域劃分為一個區,在書城場地內可以採用防火卷簾進行防火分區劃分;在人員疏散設中,應盡可能利用書城賣場的空間設較多的安全出口和增大疏散寬,其安全出口數量、寬和疏散距離可以根據人員安全疏散時間和、沉降高、 co2、 co、能見模擬算結果驗證確定;在防排方式的選擇上,應當根據建築物的幾何特點選取最適宜的措施,就大型書城建築而言,採用自然排的方式是可行的。
  3. Using the inverse model to calculate the distribution of source density, based on gauss smoke plume ' s standard density distribution, environmental capacity of fluoride in the air of northern suburban in xining was found

    摘要由高斯羽模式推導出的標準分佈推算源強分佈的反演模式方法,算了西寧市北郊地區環境空中氟化物的環境容量。
  4. It tell us : the abrasive capability of fly ash ; the similar calculation of ash erosion ; the calculation of ash erosion in the tube in turn and tube out of turn ; the reason of tube abrasion for gas flue ; the influence of air parameter for fly ash erosion ; the influence of changing temperature ; the influence of the flue gas composition, etc. next, it advances the solving measure ; reduce the flue gas velocity ; reduce the concentration of fly ash ; responsible construction : replace smooth tube with spiral tube ; use the new material of abrasion ; fuel desulfurization ; reduce so3 of flue gas ; raise flue gas temperature, making it up the dew point ; use the abrasion - resistance material to resist abrasion

    討論了飛灰磨損性能、管壁受飛灰沖蝕的近似算、灰粒對順列管和錯列管的磨損算、走廊引起對流管束的磨損機理、空動力參數對飛灰沖蝕的影響以及受熱面壁溫變化及成份對飛灰磨損的影響等問題。接著提出了解決的措施:降低平均流速;降低飛灰;使用鰭片管、螺旋翅片管代替光管;選擇合適的結構及排列方式,減少中so3的含量;提高受熱面壁溫使之大於的露點溫;採用抗腐蝕材料作受熱面等防腐蝕的措施。
  5. A gas sampling system was designed to accurately provide testing gases in demanded concentrations, and two other were specialized for the application in the identification of different brands of cigarettes and the detection of alcohol with gasoline interference. array chambers of different structures were fabricated, and the influence of the chamber ' s dimension and structure on the performance of the gas sampling system was discussed in detail. en pattern recognition system was studied

    並實現了可以按照指定的實驗室進樣系統,並在此基礎上,根據實際應用需求,設了分別用於卷鑒別和存在汽油干擾的酒精檢測的進樣系統;設製造了兩種不同結構的測試室,並分析了室的結構及其容積對于系統性能的影響,給出了比較實驗的結果。
  6. There will appear a very uneven flow field, and appear a very big velocity magnitude distribution and ash concentration distribution near back wall. thus, the velocity magnitude is far bigger than that of optimal design velocity magnitude, which will lead to serious wear and tear in metal face of heater. especially, because of curve structure in front of heat pipe air preheater, there is more serious wear and tear

    由於靠近豎井后墻面的流速很大,飛灰也較大,斷面速分佈的最大速大於最佳設的2 - 3倍,這樣將造成受熱面的嚴重磨損,特別是熱管空預熱器前端道的幾何結構有一定的轉角,更增加了磨損的程