熱膜流速計 的英文怎麼說
中文拼音 [rèmóliúsùjì]
熱膜流速計
英文
hot- film anemometer- 膜 : 名詞1. [生物學] (像薄皮的組織) membrane 2. (像膜的薄皮) film; thin coating
- 流 : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
- 速 : Ⅰ形容詞(迅速; 快) fast; rapid; quick; speedy Ⅱ名詞1 (速度) speed; velocity 2 (姓氏) a surna...
- 計 : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
- 流速 : [機械工程] velocity of flow; strength; [水文] current velocity; current speed; flow rate流速管 pi...
-
Abstract : through study on energy dissipation of goupitang project on the wu - jiang river, the velocity field in the water cushion pool downstream ski - jump or drop was measured by hot - film anemometers on a fine model with scale 1 380
文摘:結合烏江構皮灘水利樞紐工程消能問題研究,用熱膜流速儀在比尺為1 380的精細模型上量測了拱壩挑跌流在水墊塘內的流速場,並由試驗成果分析了淹沒射流在水墊塘內的消能過程,計算了消能率。Hot - film anemometer
熱膜流速計Good agreement is obtained between present cfd predictions and published experimental data of solari and bell [ 77 ]. the maximum standard error of the result is 18. 9 %. the results can reflect the phenomena of different circulation area along the height of liquid layer and above the inlet baffle
在1 . 2米塔徑的冷模篩板塔上,提出使用熱膜流速儀通過在平面內旋轉探針測量三維流速的新方法,與計算結果的對比有力地說明了該方法是正確的。Applying the computer program developed by this paper, and choosing the real values of the gear transmission, this paper has completed more than 50 sets of calculations of the thermal elastohydrodynamic lubrication based on the non - newtonian fluid. the following conclusions can be drawn according to the computational results : 1, when the gear teeth are engaged at the pitch point, the changes of both the gear rotational speed and the load have little influence on the pressure distribution and the film shape, but they have large influence on the film temperature distribution
應用本文研發的計算機程序,選用齒輪傳動的實際參數,先後進行了50餘組的基於非牛頓流體的熱彈流潤滑計算,所得的主要結論如下: 1 、當齒輪在節點嚙合時,齒輪轉速及載荷的變化對壓力分佈口太原理工大學碩士學位論文和油膜形狀的影響不大,但對溫度分佈有明顯的影響。Film cooling of the surface of a gas turbine blade was studied in a large - scale low - speed opening wind tunnel according to actual requirement of the design of aero - engine. the surface of a gas turbine blade was cooled by cylindrical holes in the experiment, with the hole number of fifteen in stator and eight in rotor
應航空發動機設計的要求,在大尺寸低速葉柵傳熱風洞中分別對發動機渦輪導向葉片和動葉表面的氣膜冷卻特性進行了研究,具體研究在不同氣膜孔出流時,在不同主流雷諾數和吹風比情況下葉片表面局部換熱系數的分佈規律。The sensor is calibrated, then the relative curve of heat flux vs thermal voltage is determined. moreover, the test of responses of steady state and transient state has been done and the results are compared with predecessors ? results, and proved to be advanced in response speed
在此基礎上對薄膜熱流計進行了穩態響應測試和瞬態響應測試,並與國外的結果進行了比較,結果表明,該熱流計在響應速度方面較快,在靈敏度方面稍低。分享友人