  1. Based on researching the function of every kind of eliminating arc loop, new concept was brought up in this paper, and the protective device for eliminating arc and overvoltage was researched and manufactured. when the arc light connecting the ground emerges, the chip synthesizing controller control the vacuum contacter which can be operated with dividing phase and make its fault phase earthed so that the arc light can be dissolved thoroughly

    本文在研究各種消弧線圈的基礎上,提出全新的概念,研製出了消弧及過電壓裝置,該裝置在出現弧光接地時,通過單片機綜合控制器控制一組可以分操作的真空接觸器,使接地,達到徹底消除弧光的目的。
  2. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的電流差動無論對於何種形式的輸電線路都是一種簡單、可靠、選擇性強的形式,電力系統的發展使得電流差動應用於線路成為需要,而電子、通信技術的發展使得電流差動應用於輸電線路成為可能。首先,本文對目前線路的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯的實現原理和實現條件及優缺點。其次,針對常規量電流差動易受正常負荷電流和過渡電阻影響的缺點,同時為加快差動的動作速度,對基於分量瞬時采樣值電流差動的原理、判據、動作特性等作了討論和分析,結果表明基於分量瞬時采樣值電流差動在可靠性、靈敏度、抗電流互感器飽和方面明顯優于常規量電流差動,對電流差動各端的同步采樣方法和數據通信也進行了分析和評價。
  3. Ground fault protection this function trips ( opens ) a circuit breaker or sounds an alarm in the event that there is an electrical fault between one or more of the phase conductors and ground ( earth )

    接地當一個或多個導線與地之間出現電氣時,接地通過跳脫斷路器或報警來示警。
  4. To resolve the situation that the sensitivity of present ground fault protection schemes is low for the large - sized hydro - generators, a kind of protection scheme based on the fault component of third - harmonic voltage and two kinds of protection scheme based on the fault component of zero - sequence voltage at the terminals and neutral are developed, and they can obtain higher sensitivity and reliability and provide 100 % protection for the stator windings. the influence of noise on the stator ground fault protection based on the local modulus maximum of wavelet transform is analyzed

    針對目前大型水輪發電機定子繞組單接地靈敏度偏低的問題,通過分析單接地后機端和中性點零序電壓的變化特點,提出了一種基於機端和中性點三次諧波電壓分量和兩種基於機端和中性點零序電壓分量的高靈敏度、高可靠性方案,並實現定子繞組的100 %
  5. The ground faults in the generator stator are by far common faults to which generators are subjected. internal short - circuit faults, which may immediately damage generator, are always preceded by the ground faults. the possibility of internal fault and damages caused by it can be decreased largely if the stator ground fault protection reliably and sensitively operates

    定子繞組單接地是發電機最常見的一種,而且往往是更為嚴重的繞組內部短路發生的先兆,定子繞組單接地的可靠與靈敏動作可以大大降低內部短路的發生幾率,減少造成的損失。
  6. If only one phase - to - ground relay operates, the operated phase is tripped in a single - pole tripping scheme ; otherwise, the tree phase of the protected line is tripped

    提出了繼電器按單設置方案, ?繼電器動作跳單,超過兩繼電器動作認為是則三跳閘。
  7. Self - protect when booting there is error indictor and no output with false setting or studying parameter

    具有自檢功能,當設置參數或學習參數不正確時,有應的指示,同時變頻器不輸出
  8. In the past 10 years, we inherit the tradition of ningbo businessman of “ to conduct ourselves honorably in commercial transaction and business activities ”, insist on the tenet of “ customer first, quality first ”, and have developed 4 series and 40 types of products, which all can provide protection on occasion of power phase lack, motor over load, motor stall, well pump leaking

    十年來,本廠繼承了寧波人素有的「文明經商、誠信經營」的優良傳統,始終抱定「用戶至上、質量第一」的經營宗旨,先後研製了4個系列、 40餘種規格的產品,都能對電機在因電源缺、電機超載、電機堵轉、潛水泵電機漏水等情況下,實施快速可靠的
  9. The device has realized the real - time control and protection for short circuit, failure to start, unbalance ( open phase ), under - voltage, earth faults, and overload

    與控制裝置實現了對短路、起動、不平衡(斷) 、欠壓、接地、過負荷的實時監控和
  10. The protection system can deal with the following motor faults : heavy over - current, over / under - voltage, over - current, current unbalance protection, repeated startings, earth fault and so on

    在此基礎上實現了針對過載、堵轉、短路、斷、逆不平衡等
  11. This paper analyzes detailedly the principles on distributed busbar protection - current instantaneous value differential method, impedance method, and put forward the new method of current fault component phase method, then compares with these methods

    本文詳細分析了分散式母線中的原理?瞬時值電流差動法、阻抗法,提出了電流分量位法的新方法,將這幾種方法進行比較。
  12. The art of computer programming, seminumerical algorithms volume 2, edition 3 addison wesley longman, inc., october 1997, isbn 0201896842. visit rst to read about their

    關注于縱深防禦(它提倡使用多個防禦策略)和(指出了系統與系統的薄弱環節未必是同的這一概念) 。
  13. Third, this thesis presents a fault location method on two point ' s different phase short circuit fault. this method only uses relaying data

    再次,分析了異地異,利用前數據和信息,研究了此種類型的測距演算法。
  14. It has been verified by simulation tests that the symmetric short - circuit protection can not only avoid the starting current but also achieve higher sensibility ; unbalance protection can distinguish unbalance short - circuit and loss of phase. the operation parameters of other protective functions has all reached the design requirements

    短路既能躲過起動電流,又有較高的靈敏度;不平衡,能準確區分不對稱短路和斷;其它功能的動作指標均達到了設計要求。
  15. Abstract : the system composed of intelligent control modules for three - phase induction motors is introduced in this paper. this module can conduct starting, reverse braking, and reverse conrtol with current limiting resistance. besides, it can also detect low voltage, overload, and open circuit of 1 or 2 phases, and do protection according to the detection. it especially fits to the controlling of motors which often do starting, braking and reversing

    文摘:介紹了一種智能三電機控制模塊組成的系統,能在串電阻(電抗)起動、反接制動和換向控制的基礎上進行欠壓檢測、過載檢測、斷檢測及電機.尤其適用於起動、制動和換向控制頻繁的電機控制場合
  16. Full bridge phase - shifted zero - voltage - switched converter ( fbps - zvs converter ) is a successful implementation for soft - switching and is easy for usage in dc / dc converter. the core technique to reach digitalization is dsp technique. in order to reach both high frequency and digitalization of converter, a fbps - zvs converter based on dsp control is proposed in this paper the converter worked on the high frequency of 150k. periphery hardware circuit is simple and its bulk is small. the converter realizes soft - switching over half load and get a high efficiency. it achieves the aim of digital control and error protect

    實現數字化的核心是dsp技術。本文立足於將開關電源的高頻化與數字化結合,具體研究內容為一種基於dsp控制的移全橋軟開關zvs變換器,該變換器工作于較高的開關頻率( 150k ) ,外圍硬體電路結構簡單、器件少、體積小;在半載以上實現了開關管的zvs開關,取得了較高的變換效率;實現數字化控制與,變換器取得了較好的性能效果。
  17. In order to analyze the characteristics of stator ground fault and develop its protection schemes, a mathematical model for large - sized hydro - generators is established based on the multi - loop theory of ac machines and considering the capacitance to ground and actual construction of the stator windings

    為了詳細分析大型水輪發電機定子繞組單接地特點,校驗和開發應的方案,本文建立了以交流電機多迴路分析方法為基礎、考慮定子繞組對地電容、採用實際繞組結構的發電機定子繞組單接地模擬模型。
  18. In addition, according to the safety requirements of underground electrical equipment, the fault characteristics and protection principle of asynchronous motors with single speed or double speed used in underground are simultaneously analyzed, the function parameters corresponding to the fault protection for high capacity motors are determined. at the same time, module program design method and compiled monitoring program and function subprogram are emphatically described. especially, more attention is paid to the design philosophy, operation principle, hardware block diagram and software flow chart of mcs

    根據礦井生產要求,分析了異步電動機的各種特徵和原理,確立了每種的動作指標;設計了主控制板的硬體電路;根據結構化程序的設計方法,設計了監控程序和各功能模塊程序;並且分析了工業生產環境存在的干擾源及所產生干擾信號的特徵,針對不同特徵的干擾信號,制定了應的硬體、軟體抗干擾措施。
  19. The operation characteristic of the new relay is analyzed in theory and verified by the simulation tests. the new relay operates with clear selectivity and high operation speed and can satisfy the demand of the protection for the ehv transmission line. the performance of the fault component impedance relay has been improved and the misoperaion of the healthy phase under cross - country fault and close - in fault have been avoided

    理論分析及模擬計算表明,基於自適應補償的突變量距離繼電器有很好的選擇性和速動性,完全能夠滿足高壓線路的需要,顯著提高了突變量距離的性能,解決了其在大電源出口單以及正反向復可能會誤跳三的缺點。
  20. Fristly, according to the non - linear characteristics of twelve - phase rectifier, the thesis gives the calculation model for a short circuit in the subway traction power supply networks which provides the academic foundation for the design of the setting values and the simulation of protection. secondly, the thesis designs the dc feeder protection and control of subway, and gives the principle of setting accordingly, after it analysizes the characteristics of electric current under tow load and short circuit and considers severel factors. to validate the rationality of the design, the thesis simulates the transient electric current under two work conditions ( starting and passing the insulation ) ahd short circuit

    其次,本文在詳細分析地鐵牽引負荷電流和饋線短路電流特點的基礎上,考慮了直流系統設計應注意的幾個因素,對地鐵饋線與控制進行配置,給出了應的整定原則,並針對某一地鐵供電系統在詳細分析了兩種工況(機車起動與過分段絕緣)的電流暫態過程,得到了電流計算的數字模型,結合前面提出的短路模型,進行了地鐵饋線的模擬,經模擬表明本文的設計是合理的。