管壁度 的英文怎麼說

中文拼音 [guǎn]
管壁度 英文
pipe thickness
  • : Ⅰ名詞1 (管子) pipe; tube 2 (吹奏的樂器) wind musical instrument 3 (形狀似管的電器件) valve;...
  • : 名詞1 (墻) wall (of a house etc ) : 銅墻鐵壁 bastion of iron2 (作用像圍墻的部分) wall of st...
  • : 度動詞[書面語] (推測; 估計) surmise; estimate
  1. Roughness may be attributable to the nature of the wall substance and the method of its manufacture.

    粗糙可歸因於材料性質及其製造方法。
  2. Finally, based on the types of all load, using matlab, the reliability programs are compiled to calculate the reliability index under different design and different load combination. the results can be used to evaluate the relatively safety, and direct the leak hunting

    最後,基於所得出的各種荷載的分佈狀況,利用matlab環境編制可靠計算程序,利用該程序計算在不同設計情況下、不同荷載組合情況下的可靠指標。
  3. This article aims at the boiler ' s problems in operation : 1 ) under nominal load, the smoke temperature at the outlet of hearth reaches 1200, far more exceeds 1050 the original designed temperature. this will always result in slag inside boiler and the temperature of overheater ' s pipe superheat, so that boiler cannot take nominal load and all these influence boiler ' s nomal operation heavily, 2 ) this article also studied the reason why the assistant oil becoming necessary when coal changes. during the nomal operation, many factors ( makeup of combustor and its disposal, smirch and encrust of water wall, excessive air coefficient, temperature of primary air, coal type and density of coal dust ) can deviate the designed working conditions, then affect the boiler ' s nomal operation

    本文針對該鍋爐在實際運行中存在的問題:在額定負荷下,爐膛出口超溫、低溫段過熱器前煙溫高達936 ,遠遠超過815的設計值;噴燃器四周水冷結焦嚴重,過熱器超標,無法帶上額定負荷;甚至有時因燃煤質量的變化,必須投油助燃的嚴重情況進行了分析研究。在實際生產過程中,燃燒器的結構、布置,水冷的粘污、結垢,過剩空氣系數、一次風溫、煤種及其濃變化等許多因素都會偏離鍋爐的設計工況,從而影響爐內的傳熱和燃燒,造成爐膛出口超溫、水冷結渣等問題。
  4. Under the precondition that the radiator has enough cooling efficiency and intension, it is the necessary trend that the volume is less, the weight is lighter, the tube wall and belt materials are thinner, and the cooling efficiency is higher

    在保證散熱器具有足夠散熱能力和強的前提下,體積更小、重量更輕、及帶材更簿、散熱效率更高成了散熱器發展的必然趨勢。
  5. Aimed at tube curve by sun shining, it analyzes and calculates the instance of curve when tube up and down face have difference in temperature, and discourses upon it influenced degree to cannon firing accuracy. for hot spread asymmetry caused tube curve, it explains it ' s form cause. for irregularly hot stress acting tube curve, it stressfully analyzes effect of body tube wall thickness difference

    重點分析了身熱彎曲產生機理,針對太陽照射下的身彎曲,分析計算了身上下表面存在溫差時的彎曲情況,論述了其對火炮射擊精的影響程;對于散熱不均引起的身彎曲說明了其形成原因;對于不規則熱應力作用下的身彎曲重點分析了身厚差的作用。
  6. The interior size and the calorific capacity of the borehole are much smaller, moreover the temperature change is slow, so usually we can neglect the influence of calorific capacity but to consider according to the heat transfer in steady state process, thus we can establish one - dimensional and the two - dimensional thermal resistance model in the borehole

    而在鉆孔內部,包括回填材料,內傳熱介質,與鉆孔外的傳熱過程相比較,由於其幾何尺寸和熱容量要小得多,而且溫變化較為緩慢,因此通常可以忽略其熱容量的影響而按穩態傳熱過程來考慮,建立了鉆孔內的一維和二維的熱阻模型。
  7. Form the point view of condenser and cooling tower as a whole, the paper studies the model of condenser performance monitoring, which includes the monitoring model of tube wall cleanness factor, the calculation model of condenser pressure target value and the optimum model of circulating water system

    本文從凝汽器和冷卻塔的整體角研究了凝汽器的性能監測模型,主要包括:凝汽器水側清潔系數的監測模型、凝汽器壓力應達值的計算模型和循環水系統的優化模型。
  8. Adopt advanced technic of f4 whole cold - press to moulding and heat melt to process to make, let the lining no slot to link withal cheek by jowl connect with exterior metalpipes wall, in the state of allowwing to work keep to distort in - phase, thereby to enhance using - life of lining in the working status of opposite high temperature high vacuum, stop the ecumenic pad fluorin pipes using in condition of cold and heat alternate and minus tension to come into being the matter of padding fluorin floor shrivel to jam the flowway and plastic rip, its perfect choice use to transport medium of strong corrosive strong oxidation by modern chemical - industry corporation

    採用氟塑料f4整體冷壓成型及熱熔加工等先進技術製造,使內襯層無縫搭接且與外層金屬緊密粘接,在允許工作狀態下能夠保持同步變形,從而提高了襯里層在相對高溫高真空的工況下的使用壽命,杜絕了一般襯氟在冷熱交替,及負壓的條件下使用易產生襯塑層鼓癟阻塞流道及塑料拉裂的問題,是現代化工企業在輸送強腐蝕強氧化介質理想的選擇。
  9. After thermodynamic calculation on several operation conditions of the furnace, cold - state flow and resistance mensuration, the combustion of the tubular - furnace hearth was changed into swirl and addition of radiate cylinder and oxygen content detection minish 1. 25 surplus air to less than 1. 15, improving the combustion condition and convection and radiate heat transfer efficacy, resuling in reducing the waste - gas temperature 45, decreasing exhaust gas loss, and saving fuel by 6 %

    摘要通過對加熱爐幾種工況進行熱力計算、冷態試驗的流場分佈及阻力測定和熱態試驗的爐膛溫場分佈及等參數的測定,確定將式加熱爐爐膛內直流燃燒改為旋流場燃燒和增加輻射筒,增設煙氣含氧量分析,可以將燃燒的過剩空氣系數從1 . 35減小到1 . 15以下,極好地改善爐膛內的燃燒狀況和對流輻射傳熱效果,從而降低排煙溫45 ,減少加熱爐排煙損失,節約了煤氣量6 %以上。
  10. Wrkd - jz type thermocouple on the wall of boiler takes 4 sheathed thermocouple as measuring element. the thermal junction is fastened in stainless steel gathering heat clump with different curved surface of bearing treble points welded or m8 screw fixed to measure surface temperature of the wall of boiler, furnace and other equipments. wrkd - hg surface sandwich thermocoupleon the wall of boiler is specialized in measuring surface temperature of round column

    Wrkd - jz型鍋爐爐熱電偶採用4的鎧裝熱電偶做測溫元件,熱接點緊固在帶有不同曲面的不銹鋼,集熱塊上採用三點焊接或m8螺釘固定,用於鍋爐,爐及其它設備的表面溫
  11. Using v2 & 5 and alkylamines ( cs - cao alkyl chain ) as precursor, vanadium oxide nanotubes which have an unique structure that alkylamines intercalate into layers of tubes wall affecting the layer spacing were prepared. their layers spacing ranges from 1. 25 nm to 3. 82 nm according to the length of alkyl chain. moreover, the growth mechanism of vanadium oxide nanotubes have been investigated and 3 - 2 - id model was established to interpret the vanadium oxide nanotubes growth process. potassium niobate is a functional materials which can be used as photochemical catalysts. lt is well known that the catalytic activites are affected greatly by the surface area of catalyst particles on which the reaction take place

    以系列烷基胺和五氧化二釩為原材料,通過簡單的水熱反應合成出了氧化釩納米,這種納米結構獨特,烷基胺作為模板劑內嵌入納米層間,成為支持納米的骨架,並影響層間距大小,納米層間距隨著烷基胺碳鏈長的不同在很大范圍內變化,通過採用不同碳鏈長的烷基胺( c _ nh _ ( 2n + 1 ) nh _ 23 n 20 )作為模板,來控制氧化釩納米的層間距,層間距可調控范圍從1 . 25nm到3 . 82nm 。
  12. The outermost layer of fluid clings to the walls of the tube, and its velocity is zero.

    最外層流體附著,速為零。
  13. Pvc standard for safety for schedule 40 and 80 rigid pvc conduit

    40和80的硬聚氯乙烯
  14. In order to improve the prediction accuracy, the sensitivities of pipe friction coefficients, pressure loss coefficients in bents, wall temperatures and heat transfer coefficients in pipes and cylinders on the volume efficiency are investigated

    為提高充氣效率的計算精,由模擬計算和相關試驗,分析了道的摩擦系數、彎的壓力損失系數、進氣和氣缸及其傳熱系數對充氣效率的影響程
  15. Depressie symptoms were associated with plaque build - up during the 3 - year study, the authors report, whereas anxiety and anger symptoms seemed to be unrelated

    研究人員使用癥狀評分法評估抑鬱、焦慮、憤怒,使用測量頸總動脈的影像學方法評價動脈粥樣硬化的程。頸總動脈位於頸部,其功能是向大腦供氧。
  16. The research result demonstrates that along with the increment of reynolds number, the root mean square value of outer fluctuating magnitude of the external diameter in fall frequency band increases, the root mean square value of fluctuating magnitude of the external diameter in high frequency band decreses, demonstrating that the fluctuation of flexible pipe wall changes fluctuation don field of original rigid pipe, large - size eddy motion increases and small - size eddy motion decreases, this reduces energy loss and increases friction reduction effectiveness

    研究結果表明:隨著雷諾數的增加,全頻帶的外徑脈動的均方根值加大,但高頻帶外徑脈動的均方根值減小,說明柔性脈動確實改變了原剛性的脈動流場,大尺渦的運動加劇,低尺渦運動減弱,從而使得能量損失減少,減阻效果增大。
  17. The circuit metal temperature is an elemental result averaged over the cycle, and shows the temperature of the metal cooling circuits

    冷卻?基於元素的結果,冷卻金屬在整個循環中的平均溫
  18. The preferences are analyzed, pipe ’ s parameters such as depth, thickness, pipe diameter, and mechanical property of material ; soil parameters such as soil types, internal friction angle, pipe - soil interaction ; fault ’ s parameters such as fault types, fault throw, fault drop, fault - pipe angle, mechanical property of material ; load types such as gravity force, linear displacement load, seismic load and seismic wave. some conclusions are drawn from the calculating results : when buried pipes cross fault, pipe ’ s embedded depth should be shallow, and big pipe diameter and thick wall should be selected. avoid the site where fault moves severe, and select suitable pipe - fault angle

    在有限元三維模型建立中考慮的因素有:道自身參數如道埋置深徑、道材料等;巖土材料參數如土體類型、巖土的內摩擦角、土相互作用等;斷層考慮有斷層類型,斷層斷距,斷層錯動距離,斷層與道的交角,斷層材料的考慮等;荷載分別考慮靜荷載,動荷載,其中動荷載包括線性位移加載、地震力加載和地震波加載等。
  19. Although strict design calculations are made to guarantee the members have sufficient strength in their work life, yet dash and improper loads may damage them during construction and in service. these damages include elastic - plastic bending and local dent in the walls of the tube. in addition, corrosive medium such as atmosphere and contaminated water can also bring corrosion damage in the walls of the tube

    雖然都經過嚴格的設計計算,以保證其在使用壽命期內有足夠的強,但在安裝施工和使用期間,往往因受到沖撞和非正常荷載而產生彈塑性彎曲和凹陷等損傷,此外大氣、受污染的水分等腐蝕性介質也可能在上產生腐蝕損傷。
  20. The hemodynamic change induced by embolization of the cerebral arteriovenous malformation was analyzed using the water hammer principle. the highest pressure that can be reached when the water hammer phenomenon occurs was calculated. the acute instantaneous pressure rising may be an important factor leading to intracranial hemorrhage or swelling when the avm is embolized. it is shown that long feeding artery of avm will increase the possibility of direct water hammer, and high wall shear stress of feeding artery will increase the water hammer pressure. this suggests that such kind of avms should be embolized stepwise and the systemic pressure should be rationally reduced before embolization

    以水擊原理分析了腦avm栓塞治療時血液動力學變化過程,計算了瞬時水擊壓力可能達到的最高值。瞬時增高的水擊壓力可能是avm栓塞時發生急性腦出血或腦腫脹的重要血液動力學因素。而avm供血動脈血面切應力偏高和供血動脈過長可增加水擊的危險程,提示對這類結構avm栓塞治療時應採取合理的降壓措施並盡可能分多次栓塞。
分享友人