  1. In order to verify the effectiveness of steep - front impulse voltage test in finding the internal faults of composite insulator, some insulators with faults, including conductive channel, semi - conductive channels, airy channel, partial little air bubble that occur separately at different place, are modeled. steep - front wave impulse voltage test is made for these faulty insulator and normal insulator

    為了檢驗陡波試驗對于發現合成子內部的有效性,分別模擬了子內部不同部位有導電性、半導電性通道,小氣泡,金屬雜質,長氣泡以及芯棒與護套間不粘連子,並從三維靜電場計算和用不同陡度的陡波試驗兩個方面進行了驗證。
  2. Analysis of ungrounded neutral ac electric network insulation fault

    中性點不接地交流電網絕緣故障分析
  3. In on - line diagnosis, time series analytic approach is used to take delivery of fault symptoms

    在線診斷中,本文嘗試了引入時序分析法提取徵兆。
  4. The second class cable ? suitable for more the earthing ? block time and more better insulated performa

    第二類? ?用於接地時間更長的系統及對電纜性能要求較高的場合。
  5. Di - on electric one of the beijing hi - new - tech enterprise develop and manufacture lots of equipment like sf6 dewpoint meter dp100, cable fault location system cfl6000 and more. di - on electric supply the most advanced technology and equipment on such as gis surge arrestor on line monitoring, resistance measuring, ac dc metrology, thermal - temperature bridge, power transformer diagnostic and testing, cable diagnostic and fault location, sf6and oil moisture measuring, oil treatment and testing, optic fiber temperature monitoring, circuit breaker testing, relay testing and more

    迪揚電氣在gis和避雷器的帶電測試與診斷分析,電力電纜的定位與局放檢測,變壓器電抗器的各種測試診斷與溫度監測, sf6的水分測量與回收,油的測試分析與濾油處理,紅外測溫與光纖在線測溫,以及各種電阻測試與計量,溫度計量與電能計量等方面擁有世界一流的技術與成熟的儀器設備。
  6. Utilising dissolved gases analysis, a new insulation fault diagnosis method for power transformers is proposed. this method is based on the group grey relational grade analysis method. first, according to the fault type and grey reference sequence structure, some typical fault samples are divided into several sets of grey reference sequences. these sets are structured as one grey reference sequence group. secondly, according to a new calculation method of the grey relational coefficient, the individual relational coefficient and grade are computed. then according to the given calculation method for the group grey relation grade, the group grey relational grade is computed and the group grey relational grade matrix is structured. finally, according to the relational sequence, the insulation fault is identified for power transformers. the results of a large quantity of instant analyses show that the proposed method has higher diagnosis accuracy and reliability than the three - ratio method and the traditional grey relational method. it has good classified diagnosis ability and reliability

    基於變壓器油中溶解氣體分析,提出了一種基於群灰色關聯度分析的變壓器絕緣故障診斷新方法.首先根據類型與灰色參考序列構造,選擇變壓器典型樣本構造多組參考序列,這些參考序列組構成一個灰色參考序列群.其次根據給出的新的關聯系數計算方法,計算個體關聯系數和關聯度.然後根據給出的群灰色關聯度計算方法,計算群灰色關聯度和構造群灰色關聯度矩陣.最後根據關聯序識別變壓器絕緣故障診斷.通過大量變壓器絕緣故障診斷實例分析,所提方法診斷準確性與可靠性優於三比值法和傳統的灰色關聯分析方法,具有較好的分類診斷能力和可靠性
  7. Model sywly - 75 physics high to foam polyethylene insulating, aluminum pipe other conductor coaxial cable suitable for catv backbone project, its interior conductor adopt bastion of iron make aluminium, other conductor adopt aluminum pipe, the two have the same hot coefficient of expansion and modulus of elasticity, woods reduce in cable conductor draw the troubles that are led to the fact

    Sywly - 75型物理高發泡聚乙烯、鋁管外導體同軸電纜適用於catv主幹線工程,其內導體採用銅墻鐵壁包鋁,外導體採用鋁管,兩者具有相同的熱膨脹系數和彈性模數,林減少了由電纜內導體拉拔所造成的
  8. In connection with the difference and distribution characteristic of the samples in sample space rs based on dga, a new self - adapted weight fuzzy omean clustering model of fault diagnosis of the power transformer based on the potential function is proposed. meanwhile, from the aspect of geometry characteristic of fc - divided in s dimension sample space, a method is proposed for the purpose of getting an effective adjacent radius, adaptive cluster number c and original cluster center of x sample set. for the diagnosis sample x, the property measure and diagnosis rule are proposed, which under the condition of potential density function that determine c number of optimal fuzzy cluster p1

    根據以變壓器dga數據為特徵量的樣本空間各樣本差異特性以及樣本在空間r ~ s的分佈特性,首次提出了基於勢函數自適應加權的變壓器絕緣故障診斷的模糊c -均值聚類模型;同時,從s維樣本空間的f ~ c -劃分幾何特性出發,提出了一種求取樣本集的類勢有效鄰域半徑和自適應求取聚類數和聚類中心初值的方法;對一個待診斷樣本,設計了基於類勢密度函數意義下的屬性測度和診斷準則。
  9. In this thesis the high voltage electric capacity equipment is adapted as on - line object of monitor and diagnose system. the system ' s structure of high voltage electric equipment is introduced, and the possible to each error occuring in high voltage capacity type equipments during the monitoring, analysis and judgment is given

    本文選擇變電站高壓電容型設備作為在線監測的對象,探討了高壓電氣設備在線監測系統的構成,在理論上分析了變電站小四器的特點,並對其在在線監測和診斷中可能出現的誤差進行了分析和判斷。
  10. A novel measurement and control system ( mcs ) used in hv flameproof switchgear has been established based on the 80c196kb single - chip microprocessor, by which electrical faults such as short circuit, over - load, over - voltage, open circuit, earth leakage and so on can be automatically distinguished and processed, and with the exception of this, the insulation degree of the double screen cables is monitored on - line. the operating condition and fault parameters can be displayed in turn with liquid crystal display

    該系統能自動判斷短路、過載、過壓、欠壓、漏電等,並對高壓電纜的水平進行實時監測,大屏幕液晶顯示器實現了電太原理工大學碩士學位論文網參數的輪流顯示,通過撥碼盤輸入系統各項整定參數,真正實現了保護系統數字化。
  11. With an introduction of cable laying and the environment for the cable, this paper classifies the cable faults recorded on the historic statistics, holds that the armored cable and the on - line detection method shall be adopted, professional evaluation system also be established for the improvement of cable operation

    介紹了上海地鐵直流電纜的敷設方式和環境,在統計歷史的基礎上對直流電纜進行了分類,提出了在新線建設和改造項目中,盡可能採用帶鎧裝的軟電纜;通過在線檢測手段,建立專家評估系統,評定的優劣並預警其劣化的趨勢;改進直流電纜敷設質量,改善其運行環境等措施和建議。
  12. While the insulation is usually the feeble tache of high voltage electric apparatus and a large part of malfunctions are brought by the destruction of insulation

    同時通常是高壓電器設備中的薄弱環節,中很大一部分就是由於破壞而造成的。
  13. The core of epiipc is the 51 series microcontrollers, which automatic detect the error signal of the circuit, like short circuit, overload, high voltage, low voltage, current leakage etc. meanwhile it monitors and tests the insulation level of high voltage cable, with convenience two variable key setting and full chinese version lcd display features

    本次研製的保護器以高檔51系列單片機為核心,能自動判斷線路中出現的短路、過載、過壓、欠壓、漏電等,並對高壓電纜的水平進行實時監測,有方便的兩鍵參數設定和全中文液晶顯示功能。
  14. The final result shows that steep - front wave impulse voltage test plays a very effective part in finding serious faults of the insulator, however, tiny faults are not easy to be found through this method

    計算和試驗結果相一致,結果表明陡波試驗在檢驗合成子嚴重內絕緣故障方面很有效,但對較輕的就不太有效。
  15. The operation reliability of the power transformer as the key equipment in electrical power systems, influences operation security of electrical power systems directly. the components and contents of gases dissolved in transformer oil can be used to reflects internal insulation faults of operating transformer. in order to overcome the errors caused by complex handling procedure and man - made factors using general chromatogram analysis method, author brings forward an on - line detecting of gases dissolved in transformer oil by using macromolecule polymer to separate oil and gases automatically and an information fusion technology of multi - sensors ; at the same time, in order to improve the accuracy and reliability, author uses neural networks to diagnose transformer faults

    變壓器作為電力系統的樞紐設備,其運行可靠性直接影響電力系統的安全運行;變壓器油中溶解氣體的成分和含量能有效體現運行變壓器內部的絕緣故障情況,為解決常規色譜分析中復雜的操作程序和由於人為因素引起的較大的誤差,論文提出了應用高分子聚合膜實現變壓器油氣自動分離、多傳感信息融合技術智能檢測多種氣體成分的變壓器油中溶解氣體在線監測技術,應用神經網路智能診斷方法實施診斷,提高變壓器診斷的準確性和可靠性。
  16. Plenty of diagnosis examples demonstrate the validity of the gray relationship analysis method in diagnosing power system insulation faults. not only the misjudgment rate can be reduced, but also the transformer fault incidences can be classified by using self - adapted weight fuzzy clustering method. further more, the transformer insulation condition can be analyzed, as well as the fault position can be located by recognizing the fault types

    經過大量的診斷實例表明:本文的模糊綜合診斷與模糊規則推理結合起來的診斷方法對電力研究變壓器絕緣故障診斷是有效的,能大大減少錯判、誤判比率;自適應加權模糊聚類方法能對變壓器的樣本正確分類,同時能有效判別類型,診斷的準確性大大高於常用的三比值法。
  17. In this thesis, the insulation failures characteristics of oil - filled transformer are analyzed firstly. then the existing measurement techniques used for on - line monitoring are compared each other in accordance with the practicability and the validity

    本論文在分析了油浸式變壓器各種絕緣故障特性的基礎上,對常見在線檢測技術的實用性和有效性進行了對比,最終採用油色譜分析法實現變壓器的狀態檢測。
  18. With the widely application of xlpe cable and the increasing defaults, the detecting technology on xlpe cable insulation has got great improvement

    =隨著電力電纜的廣泛應用和的增加,交聯聚乙烯電力電纜的絕緣故障檢測技術取得了長足的進展。
  19. Based on summarizing the present technology on xlpe faults detection and reference the pd detection method on power transformer, this paper introduces a method on recognition pd mode of xlpe. this paper uses discharging quantum and stat. arithmetic operators of chart as inputs to artificial neural network

    本文在總結前有的xlpe電力電纜絕緣故障檢測方法和借鑒變壓器局部放電的基礎上,以理論與實驗相結合,研究了基於人工神經網路的以xlpe電力電纜局部放電信號的模式識別方法。
  20. 3 ) studying the principle and method of many sensitive elements which are used to detecting the gases dissolved in oil, author bring forward the viewpoint that sensors of mq series have obvious selectivity and higher accuracy when they detect gases of h2, co, ch4, c2h4, c2h2and c2h6 dissolved in oil. especially, the accuracy of c2h2 which reflects the main faults of transformer can reach 1ul / l

    3 )研究採用多種傳感元件檢測變壓器油中多種溶解氣體的原理及方法,研製的mq型系列傳感器對變壓器油中h2 、 co 、 ch4 、 c2h4 、 c2h2 、 c2h6六種溶解氣體具有明顯的選擇性和較高的靈敏度,特別對體現變壓器內部絕緣故障較敏感的c2h2氣體的檢測靈敏度達1 l / l 。