線圈短路 的英文怎麼說

中文拼音 [xiànjuānduǎn]
線圈短路 英文
coil short
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 圈名詞1. (養豬羊等牲畜的建築) pen; fold; sty 2. (姓氏) a surname
  • : Ⅰ形容詞(空間、時間兩端之間的距離小) short; brief Ⅱ動詞(缺少; 欠) lack; owe Ⅲ名詞1 (缺點) we...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • 線圈 : [電學] coil
  • 短路 : [電學] short; short circuit; cutting out; direct short; short out; short pass短路保護(裝置) sho...
  1. Because the fault of field windings turn - to - turn shorted do not cause much effect of the operation of the machine or its fault characteristics are not very clear, most of the faults are neglected

    轉子匝間故障對機組正常運行影響不大或故障特徵不明顯,因此許多匝間故障被忽略了,但長期運行匝間故障會導致轉子一點甚至兩點接地。
  2. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧接地和經小電阻接地方式下電網的過電壓水平和接地點電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  3. According to the actuality of the present research on ct, we bring forward a new design scheme based on the rogowski coil, in this design, the protection in short circuit failure and the measurement in normal condition are both fulfilled. it can also communicate with the computer through the communicating interface, sending the parameter of the system current and accepting the instruction

    本文在考察了國內外電流互感器發展現狀的基礎上,提出了一種基於rogowski的電流互感器,該互感器具有正常電流的測量和故障時的保護功能,並且預留了與上位機的通訊介面,接受上位機的指令並向上傳送電網的電流參數。
  4. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷器所造成的事故無論是在次數,還是在事故所造成的停電時間上都占據總量60以上。因此,及時了解斷器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷器機械特性參數監測方法;提出了二次迴保護器的概念,並將跳、合閘完整性監視和二次迴保護結合起來,給出具有完整性監視功能的二次迴保護器實現方案;根據斷器生產廠家提供的斷器額定電流分斷次數,計算每次分閘對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷器殼體溫度和斷器周圍空氣溫度結合斷器熱阻來計算斷器主觸頭穩態溫升的方法,並根據此時的負荷電流間接計算主觸頭迴的電阻;在硬體電設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作電壓晶元之間的介面問題,並給出了直接聯接的接方案。
  5. In order to fulfill the protection more effectively in the short circuit failure, a new method based on the varying rate of the system current is developed. in order to get the virtual value of the system current, considering the characteristic of the rogowski coil output, a new integral method based on software is adopted and the traditional integrator is omitted

    為更好地實現電流的保護,本文針對rogowski測量電流的特點,結合對電流變化規律的分析,提出了一種基於電流變化率判斷發生的新型判據,並通過模擬實驗對本文理論部分進行了初步的驗證。
  6. The dislocation of the conductors under short circuit is virtually impossible

    當發生時,導體不致於產生位移現象。
  7. 9. the reactor is soaked with epoxy and its coil is sealed by fiberglass cloth, the great mechanical stress caused by short circuit current in reactor will be carried by sealed material, so the reactor coil is provided with the feature of high endurance for short circuit current

    9 .由於電抗器採用浸漬環氧樹脂的無緯玻璃絲帶對進行包封,在電抗器通過電流時所產生的巨大機械力由包封承受,從而使整個具有極高的抗電流能力。
  8. The hv, lv winding are assembled with the core, elastic supports are provided so as to enable the assembly to feature minimum influence ; by vibration and excellent features of impact - proof

    高低壓與鐵心組裝時,均有彈性膠墊支承。整體具有減振功能和很好的抗沖擊性能。
  9. Adopting the short circuit electric current of to formate the test prove that this contact turn on and cut off performance. according to ablation situation of contact surface after testing, have analysed that coil type double - pole amf influences electric arc

    採用電流合成試驗驗證了這種觸頭的開斷性能,根據實驗后觸頭表面的燒蝕情況,分析了式兩極縱向磁場在大電流時對電弧特性的影響。
  10. Calculation to short - circuit mechanical strength for powerformer windings

    電纜繞組變壓器線圈短路機械強度的計算
分享友人