補償線圈 的英文怎麼說

中文拼音 [chángxiànjuān]
補償線圈 英文
bucking coil
  • : Ⅰ動詞1 (修理; 修補) repair; mend; patch 2 (補充; 補足;填補) fill up; add supplement; supply; ...
  • : 動詞1. (歸還; 抵補) repay; compensate for 2. (滿足) meet; fulfil
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 圈名詞1. (養豬羊等牲畜的建築) pen; fold; sty 2. (姓氏) a surname
  • 補償 : compensate; make up; make up for; make it up to sb. ; make sth. good; compensation; offset
  • 線圈 : [電學] coil
  1. The design of east diamagnetic measurement system including diamagnetic loop and compensation loop has been given

    摘要介紹了east托卡馬克逆磁補償線圈的逆磁測量。
  2. Being added an anti - phase compensating winding, this device, which is placed between high voltage line and first insulator, makes the synthesized magnetic field in magnetic core reach a dynamic balance, and thus solves the problems from remanence and assures the measurement accuracy

    其漏電流傳感器增加一個反相的補償線圈,使得電流傳感器磁芯內的合成磁場達到動態平衡,解決了由於剩磁而帶來的問題,保證了測量精度。
  3. The verify experiment proves that its ratio and phase characteristics are much better than ordinary ones and the precision is enough for measure use. zero - flux current transformer can ’ t obtain absolute zero flux because residuary flux, so when the secondary turns is too small it will not satisfying. to improve the precision further, proposes a method to compensate zero - flux current transformer using capacitance parallel connected coil and deduces it

    為了進一步抵消剩餘磁通,提高互感器的精度,提出了一種並聯電容零磁通的方法,並進行了理論推導,設計了基於該方法的100匝電流互感器,通過校驗證明它可以改善零磁通電流互感器的比差和角差特性,提高互感器的精度,將電流互感器的二次匝數由普通互感器的幾千匝降到了100匝,提高了測量微小電流的能力。
  4. According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred

    依據可控硅控制消弧接地系統的快速可控性,一改傳統的電網正常運行時調節消弧接近於全的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過電壓;故障時立即調節消弧電感量達到與對地電容諧振,以利熄弧的新型調節原理和方法。
  5. New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized

    論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧對接地電容電流的迅速準確是減小故障危害的最主要手段。
  6. The voltage ir on core adopts semienclosed insert model. the current element adopts two - stage compensation to have wide load property. the whole plasticenclosed voltage coil. can withstand instantaneous large voltage impulse. the double jewels bearing or the magnetic - propelled bearing can ensure long lifetime. the bipolar aluminium nickel cobalt damping magnet steels have high coercivity, stable magmetic property. the electric function is in accordance with iec521 international standard

    :電壓鐵芯採用半封閉插入式,電流元件採用二級使表計具有寬的負載特性。全塑封的電壓能稱說瞬時大電壓沖擊。雙寶石軸承或磁推動軸承確保表計長壽命。
  7. Then the idea of integral control of automatic resonance and single - phase earth faulted line selection was put forward

    並在此基礎上給出了電網中消弧自動調諧與單相接地故障選一體化的綜合控制思路。
  8. Moreover, the epiipc functions properly and stably under well due to the reasonable electrical circuit design and very strong anti - jamming design. this design successfully solves the directionally power current leakage fault action and reject action, and makes it working in both neutral point non - grounded and grounded through resistors or coils under compensate systems and over compensate systems

    本次研製的保護器較好地解決了功率方向型漏電的誤動作和拒動作問題,使得它既能較好地運行在中性點不接地的系統中,又能用在中性點經消弧接地的欠系統中,同時試用於過系統中。
  9. Firstly, the temperature varies in a large range in the place where the gap sensor works, so this paper analyzes the temperature drift of gap sensor, and finds out that the main reasons which result in temperature drift are the resistance of detecting coil and demodulating circuit parameters. to resolve this problem, a practical design of detecting coil is given, and a compensative measure considering the detecting coil and demodulation circuit is proposed to improve the temperature stability of gap sensor

    首先,針對間隙傳感器工作環境溫度變化較大的情況,本文對間隙傳感器溫度漂移現象進行了分析,認為檢測電阻和檢波電路參數變化是造成傳感器溫漂的主要原因,建立了檢測的數學模型,提出了檢測和檢波電路綜合方法,解決了間隙傳感器的輸出信號溫度穩定性的問題。
  10. The advantage of this method is that, the compensation loop is applied for eliminating the change of toroidal flux produced by the toroidal coils and the adjustable structure can be used to decrease the error signals come from the poloidal field

    該方法的優點是補償線圈有效地消除了縱場產生的磁通變化,而調節機構能降低來自極向場的誤差信號。
  11. Sb2011 precise decade inductance box adopts loop inductance coil, emc screen, special temperature compensation structure, aging technology, and whole - seal moistureproof measure therefore, it possesses many special characteristics, such as strong anti electromagnetic capability, little effect by humidity and temperature, perfect stability, reliable performance, strong adaptability, novel structure, and easy to operate

    Sb2011型精密十進位電感箱採用鐲環形電感及電磁屏蔽,獨特的溫度結構與老化處理工藝並採取全封閉式的防潮措施,具有抗電磁干擾能力強、受濕度與溫度影響極小、穩定性好、性能可靠、適應性強、結構新穎、操作方便等獨特優點。
  12. In this paper, the research was made to solute these problems. the peterson coil compensation system has been designed which can measure capacitor current and damp degree ; a fault selection method of distribution network which was put forward that based on ftu

    本課題就這兩方面的問題進行了深入研究,設計了一種消弧自動裝置,該裝置可測量系統對地電容電流和阻尼率,具有響應快、準確性高的優點;同時提出了一種基於ftu的配電網接地選方法。
  13. The paper explains the method of the petersen coil parameter selection and expatiates the working principle of micro - computer controller. new methods of on - line measuring of the capacitive current and the control of the series resistance are put forward ? which lead to the integration of the automatic resonance and the faulted line selection in a compensating network

    文中說明了消弧參數的選擇方法,闡述了微機控制器的工作原理,提出了在測量電網對地電容電流以及控制串聯電阻的新方法,實現了電網自動調諧與單相接地選的一體化。
  14. To solve these problems, the compensating method of neutral point grounding through peterson coil is commonly used in our country

    為了解決這一問題,我國現在普遍採用中性點經消弧接地的方式。
  15. Considering the actual condition and development of the 35kv distribution network in changzhi district ? a new type of automatic resonance devices with on - line tap - changer is developed for the capacitive current compensation and faulted line selection in case of an earth fault

    結合長治地區35kv配電網的實際情況和發展趨勢,研製了新型調匝式自動跟蹤調諧消弧接地裝置,用於電網單相接地故障時的電容電流和接地選
  16. In recent years, with the large - scale reconstruction of city power system, the scale of power system is continuously expanding, and the power supply network is becoming larger and larger. in addition, the enormous use of cables in city power system increases the current through the grounded capacitor. these lead to more and more instantaneously grounding faults unable to eliminate naturally

    近年來,國家對城市電網的大規模改造,使得電網的規模不斷發展,配電網路越來越大,加上城網中大量使用電纜,使接地電容電流大大增加,越來越多的瞬間單相接地故障不能自動消除,為了解決這一問題,我國普遍採用中性點經消弧接地的方式。
分享友人