補償電容 的英文怎麼說

中文拼音 [chángdiànróng]
補償電容 英文
building out capacitor
  • : Ⅰ動詞1 (修理; 修補) repair; mend; patch 2 (補充; 補足;填補) fill up; add supplement; supply; ...
  • : 動詞1. (歸還; 抵補) repay; compensate for 2. (滿足) meet; fulfil
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • 補償 : compensate; make up; make up for; make it up to sb. ; make sth. good; compensation; offset
  • 電容 : electric capacity; capacitance; capacity
  1. Rated frequency : 50 60hz rated capacitance : 1f - 100f

    Cbb60b燈具用功率因素補償電容
  2. Appling closed loop control strategy in the power factor dynamic compensation system. then the key techniques, for example, the fashion of real time sampling idle current and the fashion of compensation capacitor connected with, the time when the compensation capacitor are thrown up, are researched

    針對本系統的應用對象,確定了本系統中所應用的無功流實時檢測理論和方式、補償電容器接線和分組方式、補償電容器投入時刻的選擇等關鍵技術;並對can技術應用於功率因素動態系統進行了研究。
  3. Exchange non - clearane metal oxidate matter arrester is suitabe for the voltage protection of transformer switch cupboard, vacuum switch etc

    交流無間隙金屬氧化物避雷器,適用於變壓器、配屏、開關櫃、真空開關、輸線路、力計量箱、並聯補償電容器、旋轉機等壓保護。
  4. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變站的運行記錄,指出了導致該站器湯6c頻繁燒保險的主要原因是5次諧波流含量偏高,引起湯7c放pt爆炸也是因為7次和9次諧波流被放大。針對這些導致湯陰變補償電容器故障的原因,提出了相應的諧波治理措施,包括針對湯6c器5次諧波流含量偏高的原因,提出了停運湯6c器或者通過把湯sc器的部分量併入湯6c器(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低壓側7次和9次諧波流被放大的現象,提出了在湯7c器上加裝一定百分比的串聯抗器的措施。
  5. With the development of the electric power system, static - state reactive power compensators ca n ' t have met the requirements of the actual production and operation, and the trend to the fast and dynamic compensation for reactive power become greater and greater. since ertan hydroplant and 500kv transmission systems in sichuan power system have been operated, many power plants of load center are forced to halt during the high - water period, because the great deal of power is transmitted to far - distance load center. thus the load center loses voltage sustentation and the level of the system stabilization is debased greatly

    四川網的二灘水站和500kv輸變系統投入運行后,由於二灘水站的大量力遠距離輸送至負荷中心,迫使負荷中心的火機組在豐水期大量停機,使負荷中心失去壓支撐,大大降低了網的壓穩定水平;同時,因為四川網中的無功裝置全為靜態無功補償電容器(或抗器) ,這些設備只能在系統正常運行狀態下起到無功壓支撐的作用,而在網出現事故時,不但不能起到壓支撐作用,反而會促使壓崩潰事故的發生。
  6. On the base of widely investigating and researching, author deems that the conventional reactive power compensation devices used by consumer had many defects with among others : lower response time, remaining residual voltage on the compensation capacitors, and so on. because of existing improper trigging time, it is impossible to realizing balance compensation for 3 - phrase unbalance loads

    本文在充分調研的基礎上,認為目前採用的傳統的無功功率裝置存在響應速度慢、觸發時刻不合適、補償電容器上有殘壓、不能實行三相平衡、對網產生污染、不能消除負荷本身產生的高次諧波等弊病。
  7. Cbb60b compensation capacitor for lighting fixtures

    Cbb60b燈具用功率因素補償電容
  8. The characteristics of damping shows that the uncompensated parallel ac transmission line can release the coupling between the hvdc and generator and improve the damping of the system, hence the possibility of subsynchronous oscillation decrease. in such a system scheme, the hvdc system dominates the changes of damping due to the small magnitude of the damping provided by ac line. when the ac transmission line is compensated with a fixed series capacitor, the situation will be totally different

    其中,並列運行的無串交流輸線路可以緩解hvdc與其臨近機組之間的機耦合程度,改善hvdc的氣負阻尼特性,從浙江大學博士學位論文摘要而減輕機組發生次同步振蕩的危險性,此時系統的整體氣阻尼特性由hvdc的性質決定;但若交流線路中存在串聯補償電容,則系統幅值較大的氣負阻尼不僅可能使整流站機組發生次同步振蕩,逆變站附近機組同樣存在發生次同步振蕩的可能性,此時系統的整體阻尼特性由串聯補償電容的性質決定。
  9. First the paper use the different four network operating condition as the primary given conditions and set the 330 / 220kv transformer tap changer position in the standard position, adding the paralleled capacitor bank sets one by one into the network to change the amount of the input reactive power, thus obtained four sets of the 330kv and 220kv bus voltage and the active and reactive power losses changing curves

    進而研究了在每一確定並聯補償電容器組投入量條件下,隨聯變調壓檔位變化而產生出的一組並聯量、母線壓與損耗的變化曲線。進而選出了隴南網在四種選定網運行方式下、有功損耗最小條件下的最優綜合控制組合曲線。
  10. Then the paper uses the same typical four network operating conditions as the primary given conditions and when adding one set of the parallel capacitor bank, changing the 330 / 220kv transformer tap changer position step by step to change the transformer ration, through this study methods this paper found out all the optimized combination of the tap changer position and the amount of input reactive power, also obtained four sets of the 330kv, 220kv and hokv s / s bus voltage and the active and reactive power losses changing curves. through analyzing the optimized combination control curve and the network power flow, the paper generalizes the rules as following : the chief measure of coordinative control is inputting shunt reactor in chengxian s / s in winter time both in the planning year of 2010 & 2005 ; in summer time in planning year of 2010 the chief measure is to input proper shunt capacitor

    本研究通過分析所獲得的最優綜合控制組合曲線及網潮流,總結出了如下規則:隴南網在2005年及2010年冬大、以及2005年夏小運行方式下,綜合控制應以成縣變投入適量並聯抗器作為主要措施;在2010年夏小運行方式下則投入適量並聯補償電容器作為主要措施,再輔助以選擇合適的主變有載調壓分接頭來調節,達到控制網內無功潮流分佈合理、各變站母線壓在理想的范圍內時網有功損耗最小,從而也提高了網安全運行水平及供質量。
  11. With the consideration of most of our transformers " taps are changed manually and some fluctuate unnecessarily, this paper presents a supervision system of oltc based on plc control technique. then we combine this system with reactive power compensate device such as shunt capacitor to design a new supervision system of substation voltage and reactive power synthetic control based on plc fieldbus

    針對國內變壓調整大多依靠人工調節,且有載調壓變壓器( oltc )分接頭動作頻繁的特點,本文提出了基於plc控制技術的有載調壓監控系統的研製方法,並以此監控系統為基礎,結合併聯補償電容器組等無功設備,設計了一種基於plc現場總線的變壓無功監控系統。
  12. In order to ensure the whole system operate economically, power department equip transformer with onload tap changer and shunt capacitors for most distribution substations, according to the operating condition, adjusting the position of transformer taps and capacitors can control the variation of voltage and reactive power exchanger of distribution substations and power system in certain extent

    為確保整個系統運行經濟性,降低網損,力部門在大多數變站配置了有載調壓變壓器和並聯補償電容器組,根據運行情況適當調節變壓器分接頭的位置和投切並聯補償電容器組,可以降低壓變化和變站與系統的無功交換控制在一定的范圍內,確保供質量和網運行的經濟性。
  13. It is composed of a reactor and in series with a compensation capacitor, which is paralleled with a by - pass reactor controlled by a gto pair

    本文研究了一種帶串聯的故障限流器的模型,它由補償電容和旁路感並聯后與限流感串聯而成。
  14. A variable reactance can be realized by duty ratio control. then the fcl can attain to the goal of controllable limiting fault current and controllable series compensation. first, the topology of pwm - fcl is proposed based on the analysis of others " s research

    它是由一個以pwm原理控制的感模塊和一個補償電容並聯后,再與一個限流感串聯而成,改變脈沖的占空比可以得到變化的阻抗,實現限流和串聯
  15. Making use of the idea of the parallel genetic algorithms, presenting the adaptive multiple subpopulation evolutive strategy. presenting extinction and immigration strategy in order to avoid the similar or even same individuals appear. in order to enhance convergence velocity of reactive power optimization of the radial distribution system, combining the characteristic of the radial distribution system, a sensitivity analysis approach was build up for optimal selection of capacitors and mutation of transformer tap changer

    為了提高配網無功優化的收斂速度,結合配網的特點,提出採用簡單可行的靈敏度公式選擇無功器的安裝地點,並用靈敏度分析變異變壓器分接頭,使變異運算元的選取更符合配網無功優化問題中關于調節變壓器分接頭的實際情況,減少了一些不必要的變異運算,使適應性和魯棒性加強;根據實際情況採用無功補償電容器的啟發式變異,使變異運算元的選取更符合無功優化問題中關于補償電容器的實際。
  16. The device can measure reactive parameters in distribution power net which are generally considered to he difficultly measured the paper also introduces the calculating method of the reactive compensation capacity and its optimal location, the design method and realization principle of the series devices, such as the reactive power acquisition device, the reactive power optimized controller and the compensation capacitor operator, is seated in detail through economic and technical comparison, a realistic hardware scheme of reactive power compensation system is proposed

    文章利用磁感應原理和數字通訊技術結合試驗設計出源自給式高壓線路無線信號採集裝置,解決了配網分支線路無功參數不易測量的問題。文章還介紹了系統無功量及安裝位置的計算方法,較為具體的講述了無功功率採集器、無功優化控制器以及補償電容操作器等一系列裝置的設計方法和製作原理。通過經濟技術比較提出了一整套切實可行的無功系統硬體製作方案。
  17. The 2 - stage differential transconductance amplifier is used in the design to achieve high gain. in the design of amplifier, a resister and a miller capacitor is used to deal with the stability and frequency compensation

    系統中採用差分跨導運算放大器的設計,為了保證其具備高增益與高穩定性,選用二級結構,並且增加了補償電容阻。
  18. Then computation modules for line loss and flow are built up with considering building out capacitor, with the net communicate system based on the technology of field bus

    基於以現場總線為紐帶互連成的現場網路數據通信系統,建立補償電容后的潮流計算模型及線損計算數學模型。
  19. According to the characteristic of nine - area diagram of substation vol / var coordinated control, this system gives the defination of fuzzy sets and the degree of membership of input / output variables, and designs corresponding control rules. the results of simulation demonstrate the system can satisfy the constrains of the day - adjusting times of the switching of on - load transformer and paralleled compensation capacitors, and ensure voltage quality, reactive power basical balance. considering the var requirement in different load time period and the control demand in load saltation, a improved control scheme is provided. the results of simulation show the improved scheme can meet the demand of vol / var in different load time period, protect the wrong operation when either voltage or reactive power appears saltation, and decrease the times of regulation of the switching of on - load transformer and paralleled compensation capacitors finally, a background software module of substation vol / var coordinated control is designed, based on the supervisory control and data acquisition system of substation

    模擬結果證明該系統能在各種負荷條件下確保壓合格和無功基本平衡,且能滿足變站對有載調壓變壓器分接頭日調節次數和並聯補償電容器組的日投切次數的限制。通過考慮不同負荷時段對無功功率的需求和負荷突變情況下的控制要求,對上述模糊控制策略進行了改進,模擬結果證明改進后的控制策略能滿足不同負荷時段對壓和無功的要求、抑制壓或無功突變情況下的誤動作,且有效地減少了有載調壓變壓器分接頭和並聯補償電容器組的調節次數。最後基於變站scada系統設計了一后臺壓無功綜合控制軟體模塊。
  20. Studies on some distribution test systems show the power flow analysis of distribution systems to have the superior performance in terms of solution time and convergence characteristics. the thesis proposes two algorithms for real - time switching control scheme of shunt capacitors

    在配網中布置有許多並聯補償電容器組,它們在網路經濟運行中所起的作用不同和運行現場的技術條件不同,它們的實時運行控制採用不同的控制方式和控制演算法。
分享友人