跳合閘參數 的英文怎麼說

中文拼音 [tiàozháshēnshǔ]
跳合閘參數 英文
tripping-closing parameter / auto-reclosing
  • : 動詞1 (腿用力彈起) jump; leap; skip; bounce 2 (彈力使物體突然向上移動) spring; leap 3 (一起...
  • : 合量詞(容量單位) ge, a unit of dry measure for grain (=1 decilitre)
  • : anchor gate
  • : 參構詞成分。
  • : 數副詞(屢次) frequently; repeatedly
  1. Measuring of lightning parameters is the base work of lightning research. it is very important for researching the lightning characteristics, analyzing the accident of lightning, identifying the responsibility of lightning strike outage accident and discussing the strategies of lightning protection. it also can provide precise original data of atmosphere over - voltage for designing insulation co - ordination

    雷電流的測量是進行雷電研究的基礎工作,對于研究雷電特性、分析雷害事故、鑒定雷擊事故責任、探討防雷對策及為絕緣配設計提供精確的大氣過電壓原始據均具有十分重要的意義。
  2. This can fully consider the effect of the structure of transmission line and the selection of lighting parameter etc. by calculating and analyzing various of factor that affect the lightning tripping probability of 500kv double circuit transmission line, we can draw the conclusions : the result by intersecting method is more accord with the practicality circumstance than by existing standard methods, using unbalance high insulation and reverse sequence of wire can reduce the contemporary outage rate of double circuit line, reducing the footing resistance is one of the most efficiency method to reduce the back stroking rate of double circuit transmission line, the double back stroking rate and the single back stroking rate will fall by three ground wire, when the footing resistance is 10 ohm, the back stroking rate by three ground wire is 83 percent of by two ground wire

    在分析輸電線路繞擊耐雷性能時,對線路的雷電屏蔽問題進行了分析,提出對擊距法進行改進,充分考慮了風速的影響因素,編寫了具有工程實用價值的計算線路繞擊耐雷水平的程序,此方法可以充分考慮線路結構和雷電等對繞擊率的影響。通過對影響500kv同桿雙回線路雷擊率的各種因素進行了計算和分析,得到以下結論:採用相交法的計算結果比定義法更符實際運行情況。採用不平衡高絕緣方式和導線逆相序排列可以大大降低雙回同時率。
  3. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次,還是在事故所造成的停電時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性監測方法;提出了二次迴路保護器的概念,並將線圈完整性監視和二次迴路保護結起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路電流分斷次,計算每次分對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷路器殼體溫度和斷路器周圍空氣溫度結斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的負荷電流間接計算主觸頭迴路的電阻;在硬體電路設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作電壓晶元之間的介面問題,並給出了直接聯接的接線方案。
分享友人