酸度誤差 的英文怎麼說

中文拼音 [suānchā]
酸度誤差 英文
acidity error
  • : 酸構詞成分。
  • : 度動詞[書面語] (推測; 估計) surmise; estimate
  • : Ⅰ名詞(錯誤) mistake; error Ⅱ動詞1 (弄錯) mistake; misunderstand 2 (耽誤) miss 3 (使受損害...
  • : 差Ⅰ名詞1 (不相同; 不相合) difference; dissimilarity 2 (差錯) mistake 3 [數學] (差數) differ...
  • 酸度 : [化學] acidity酸度計 acidimeter; acidometer; 酸度檢定 acidity test; 酸度控制 acidity control; 酸...
  • 誤差 : error
  1. The s - l - e experiment data for the eight binary condensed systems of fatty alcohol / fatty acid were treated by using the improved equation, and the equation was examined with experimental data. at the same time, we used ideal model to predict the tenary s - l - e of n - octadecane / lauric acid / stearic acid system, and we got an accurate result of the simple eutectic temperature. the relative error is 0. 51 % comparing with the experimental result, so we will offer a method of prediction for quickly obtaining multicomponent system phase change materials this article calculated the pcms quantities and energy saving effect in theory, designed the experimental apparatus to measure the energy saving effect, and analyzed the temperature equalization action of the pcms by comparing experiment

    利用這種方法,建立了適合醇-羧等系列二元體系的單參數margules方程,本文對醇-羧系列等8個二元凝聚體系的單參數margules方程的參數進行回歸,並利用整個實驗數據對模型進行了檢驗,另外,本文利用理想狀態模型對一個三元體系18烷-月桂-硬酯相圖進行預測,通過與實驗數據進行比較,預測的低共熔溫與實驗測定溫較為吻合,其相對為0 . 51 ,這將為快速獲取多元體系的相變材料提供預測方法。
  2. A resolution method in software is applied to calibrate zero point and full scale of the circuit. software approach to nonlinear correction for sensor and circuit is presented. therefore system error is eliminated, and measurement accuracy of temperature is improved. the signal of acidity electrode is detected by a differential amplifier circuit, which consists of operational amplifiers tlc2254 with high input impedance and low drift

    採用橋路和單運放動放大電路對溫傳感器信號檢測放大,軟體校正溫傳感器和測量電路的非線性,軟體校準測量電路的零點和滿,消除測量電路的系統,提高補償溫的測量精;採用高阻、低漂移運放tlc2254組成高阻動放大電路用於電極信號測量。
  3. Abstract : an imidazole - catalyzed acylation method of phthalic anhydride is applied to the determination of hydroxyl values of reinforcing agent is211. the analytical error is 5. 0 10 - 3. the relative standard deviation of the method is less than 0. 04 and its coefficient of variation is not more than 5. 0 10 - 3. hydroxyl values determined in different batch samples meet the design requirement completely. this method is rapid and simple, it is adaptable to conventional analysis

    文摘:以咪唑催化鄰苯二甲酐酰化的方法測定增強劑is211的羥值,準確高,分析為5 . 0 10 - 3 ;方法精密好,標準偏小於0 . 4 ,變異系數不大於5 . 0 10 - 3 ,測定不同批號試樣的羥值完全符合商標值,方法快速、簡便,適用於常規分析。
  4. Results of experiments show that accuracy of temperature and acidity arrive at 0. 2 and 0. 02ph respectively

    實驗數據表明補償溫的測量小於0 . 2 ,的測量小於0 . 02ph 。
  5. Abstract : the germinating capacities, fatty acid values and viscosities of wheat samples were analyzed by determining the viscosities, germinating capacities and fatty acid values, etc, which are the indices of quality deterioration, of 53 types of different wheat samples and the retrogradation degree and quality state of grains were showed through fatty acid value, germinating capacity, senes analysis and taste evaluation, however, wheat quality was evaluated by only viscosity which would cause greater error

    文摘:本研究通過測定53個不同品質小麥樣品的粘值、發芽率和脂肪值等品質劣變指標,分析了發芽率、脂肪值和粘之間的關系,並認為脂肪值、發芽率、感觀分析及品嘗評分結果都能較好地說明糧食的陳化程和品質狀況,而粘值用於評價小麥的品質則會產生較大的
分享友人