阻抗測量儀 的英文怎麼說

中文拼音 [kàngliáng]
阻抗測量儀 英文
impedometer
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : Ⅰ動詞1 (抵抗; 抵擋) resist; combat; fight 2 (拒絕; 抗拒) refuse; defy 3 (對等) contend with...
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 名詞1 (人的外表) appearance; bearing 2 (禮節; 儀式) ceremony; rite 3 (禮物)present; gift 4 ...
  • 阻抗 : [電學] impedance
  • 測量 : measure; survey; gauge; meter; measurement; measuring; surveying; mensuration; metering; gauging;...
  1. A new measurement system for electrical conductivity in an yj - 3000t press fitted with a wedge - type cubic anvil was set up on the basis of the old one. a solartron 1260 impedance / gain phase analyzer was used in the new system ; mo electrodes and a mo shield were also used to keep oxygen fugacity close to the mo - moo2, which is similar to that of iron - wustite ( iw )

    在yj ?緊裝式六面頂壓機上,對原有的礦物、巖石電性系統進行了進一步的改進:建立了一套以solartron1260增益?相位分析器,使用mo電極和mo盾來控制樣品氧逸度的系統,該系統的氧逸度環境為mo ? moo _ 2 ,接近iw緩沖對。
  2. It combained potentiostat, potentiostatic circuit instrument and ac impedance measurement organticace, which can measure usual dynamic potentio - scan, experiment of dynamic potentio - scan, but also unique measurement of ac impedance measurement, also, this new type electrochemical workstation can carry on complex experiment, sucn as potentio / current scan ac impedance measurement procedural measurment, life - span - circle ac impedance measurement procedural measurement in order to fullfill the goal of track and analysis of parameter in various electrochemical conditions. this graduation thesis indicate the structure, function of the multifunct - ional electrochemical workstation

    它把恆電位,恆電流和電化學交流分析有機地結合到一起,既可以做常規的基本試如動電位掃描、動電流掃描試驗和電化學交流,也可以做基於這三種基本試驗的程式化試驗,如恆電流充電-電化學交流,電池壽命循環試驗-電化學交流試驗,從而完成多種狀態下電化學體系的參數跟蹤和分析。
  3. Di - on electric one of the beijing hi - new - tech enterprise develop and manufacture lots of equipment like sf6 dewpoint meter dp100, cable fault location system cfl6000 and more. di - on electric supply the most advanced technology and equipment on such as gis surge arrestor on line monitoring, resistance measuring, ac dc metrology, thermal - temperature bridge, power transformer diagnostic and testing, cable diagnostic and fault location, sf6and oil moisture measuring, oil treatment and testing, optic fiber temperature monitoring, circuit breaker testing, relay testing and more

    迪揚電氣在gis和避雷器的帶電試與故障診斷分析,電力電纜的故障定位與局放檢,變壓器電器的各種試診斷與溫度監, sf6的水分與回收,絕緣油的試分析與濾油處理,紅外溫與光纖在線溫,以及各種電試與計,溫度計與電能計等方面擁有世界一流的技術與成熟的器設備。
  4. Manufacturer of high voltage resistors, power and precision resistors, high voltage dividers, hybrid circuits, resistor networks, pressure and force sensors and load cells

    -生產ai - 6000自動干擾精密介質損耗,氧化鋅避雷器,地網接地電,油介損電
  5. Is used with a spectrum analyzer or measurement receiver

    Hm6050 - 2電源穩定網路一般與頻譜分析接收機一起使用。
  6. The instrument adopts the theory of ultrasonic echo for quickly scanning river bed topography under water and employs the principle of resistance for measuring river bed topography upon water and shallow beach topography, which increases the measuring speed effectively and decreases the disturbing influence on river bed

    器採用超聲原理實現了水下地形的無接觸快速掃描,採用原理實現了洲灘、邊灘、淺灘的地形,有效提高了速度,並減小了對河床的擾動影響。
  7. Our national capacitance metrology level in the low frequency range ( below 10 khz ) has reached the international advanced level. but with the development of science and technology, there exists a big difference between our national and international advanced level in the aspect of the frequency range and the capacitance range etc, especially in the aspect of the frequency range. so the capacitance metrology technology in high frequency cannot meet the need of testing for impedance metrology standards and the measurement instruments

    在低頻段( 10khz以下) ,我國電容計水平已達到國際先進,但隨著科技的發展,在頻率范圍、值范圍等方面與國際先進水平有較大的差距,特別是在頻率范圍方面,不能滿足進口標準器及其器的檢定試要求,迫切需要在頻率范圍上進行擴展。
  8. The alternating resistance method was adopted to test the moisture content of the fiber, the bathtub effect on the alternating conductivity, which insisted in the fiber, was verified, the sensitive frequency band of measuring the moisture content of the fiber was acquired, and the dielectric polarization theory was applied, the organism of the bathtub effect of the alternating conductivity of the fiber was gained

    採用交流纖維水分,驗證了纖維存在交流導電浴盆效應現象,找出了纖維水分的敏感頻帶,並運用介質極化理論,說明了纖維交流導電浴盆效應的機理。第三章新型纖維水分快速設計:運用纖維交流特性,設計了新型纖維水分快速
分享友人