離子分析儀 的英文怎麼說

中文拼音 [zifēn]
離子分析儀 英文
ion analyser
  • : Ⅰ動詞1 (離開) leave; part from; be away from; separate 2 (背離) go against 3 (缺少) dispens...
  • : 子Ⅰ名詞1 (兒子) son 2 (人的通稱) person 3 (古代特指有學問的男人) ancient title of respect f...
  • : 分Ⅰ名詞1. (成分) component 2. (職責和權利的限度) what is within one's duty or rights Ⅱ同 「份」Ⅲ動詞[書面語] (料想) judge
  • : Ⅰ動詞1. (分開; 散開) divide; separate 2. (分析) analyse; dissect; resolve Ⅱ名詞(姓氏) a surname
  • : 名詞1 (人的外表) appearance; bearing 2 (禮節; 儀式) ceremony; rite 3 (禮物)present; gift 4 ...
  • 離子 : [物理學] ion
  1. Equipment and instruments : electronic analytic balance, uv and vis spectrophotometer, 97rt fluorescence spectrophotometer, gas chromatograph spectrometer, high speed centrifugal machines, leica rm 2015 microtome, fluorescence microscopes, pcr amplifier, and so on

    :電天平、紫外可見光光光度計、 97rt熒光光光度計、氣相色譜(附4種檢測器) 、高速心機、病理切片機、熒光顯微鏡、 pcr擴增等。
  2. Ioniza calcium andlyzer

    離子分析儀
  3. In the paper the structure and principle of the secondary ion mass spectrometry ( sims ) are reported, and its typical applications in the hgcdte material and devices processing, especially in the measurement of the junction depth and the quantity analysis of trace impurity are introduced

    摘要文章介紹了二次質譜的結構及其基本工作原理,並通過對典型應用的,介紹了二次質譜技術在高靈敏度碲鎘汞紅外焦平面探測器材料和器件制備工藝中的作用,特別是在結探監測和微量雜質監控方面所發揮的重要作用。
  4. The recent progress in the instrument, analytical technique of laser ablation inductively coupled plasma mass spectrometry ( la - icp - ms ) in metallurgical analysis has been reviewed

    摘要從器發展、技術應用研究等方面介紹了近年來激光燒蝕進樣電感耦合等體質譜法( la - icp - ms )在冶金領域的最新進展。
  5. And the report has passed the analysis to ionic membrane caustic soda salt refining handicraft, has suggested that controlling a scheme comparatively rationally, calculation and driving force having carried out the ability choosing a type, circulating to the regulating valve on various appearance ( the temperature, pressure, rate of flow, liquid place, component ) supply a problem waiting for aspect to have done one by one also expound

    本報告通過對膜燒堿一次鹽水精製工藝的,提出了較為合理的控制方案,並對各種表(溫度、壓力、流量、液位、成)進行了選型,對調節閥流通能力計算及動力供給問題等方面也都一一作了闡述。
  6. Study on the impurities in synthesized pioglitazone hydrochloride by hplc - esi ion trap mass spectrometry

    阱質譜聯用鹽酸匹格列酮中的雜質
  7. Ion micro probe analysis method

    微探針質譜
  8. Currently the laboratory is capable of fire assay gold , base metals by aas using various digestion methods and a 34 element suite by icp

    實驗室進行火試金法,以不同的溶樣方法用原吸收光譜進行賤金屬測試,以及用等體直讀光譜進行34種元素的測試。
  9. Gd0511na sodium concentration analyzer

    型鈉濃度
  10. The distribution characteristics of the metals from the intertidal sediments of jiaozhou bay ( 1 ) the results shown that, the available concentraion of zn is ranged 53. 88 - 143. 21 g / g ( dry weight ), cu is ranged 18. 56 - 65. 34 g / g ( dry weight ), cr is ranged 10. 82 - 105. 49 g / g ( dry weight ), pb is ranged 2. 14 - 31. 92 g / g ( dry weight ), cd is ranged 0. 04 - 0. 836 g / g ( dry weight ), hg is ranged 0. 005 - 0. 115 g / g ( dry weight ), eh is ranged - 307. 9 - 84. 4mv, ph is ranged 7. 589 - 8. 019, the sediment in jiaozhou bay is featured by reduction, so the sediment of jiaozhou bay deposied well

    離子分析儀測得沉積物中重金屬相關參數氧化還原電位eh的范圍為307 . 9 84 . 4mv , ph的范圍為7 . 589 8 . 019 ,說明膠州灣沉積物有較強的還原性,重金屬沉積較好。為將汞相對于濕樣的含量轉化為相對于干樣,測得沉積物含水率的范圍為23 . 2 34 . 8 。
  11. Abstract : this paper reports the observation and analysis results on three kinds of impurity in - al2o3 by using epma - eds. we studied the differences of electric conductivity between the area containing inmpurity and the normal area by ion transport method. the effects of impurity in - al2o3 on cycle life of the na - s cell were also discussed

    文摘:用epma - eds組合,對氧化鋁中的三種典型雜質進行了形貌觀察和成,並用電束誘導遷移法,研究了雜質區及正常區的電導差異,討論了不同雜質的特點及對氧化鋁作用中的危害。
  12. Suppressor is the key part for ic instrument, and developing a high performance suppressor for ic instrument is quite important to gradient ion chromatography, to analysis of some ions which have strong affinities with the functional groups located on the surface of the pellicular ion exchange column packing

    抑制柱是色譜的一個核心部件,研製具有較高抑制容量的抑制柱對于色譜法的梯度淋洗、對于在柱上保留時間長的具有重要的意義。
  13. They used liquid and gas chromatography to fractionate the sample into its molecular constituents ; an electron beam then fragmented the separated molecules in a mass spectrometer to produce a spectrum indicating the basic chemical components

    他們運用液相與氣相層法,將樣本的組成開,然後導入質譜,以電束使已斷裂,進而產生出可識別基本化學組成的圖譜。
  14. The apsp produced abroad is made by numerical controlled machine tool, which has noise level of 71db ( a ), the apsp produced in our country is made in the method of exploratory which has noise level of 73db ( a ) and 75db ( a ). in order to analyze the influence of stator curve to noise, the author used tri - coordinate measuring instrument to measured exactly the inside surface of stator and got the straddling point coordinate, and made curve fitting by using matlab as language and studied the fitting effect and then worked out the equation of stator transition curve in return seeking, then comparied this method with the standard style and made the conclusion : the equation of atator transiting curve of apsp made by numerical controlled machine tool is close to theorical 5 power curve standard style, but compared with it, the stator transiting curve of apsp produced in exploratory has a major error. combining the testing results of noise, one can know that the qualily of stator transition curve play an importance to t he noise of the pump

    國外生產的汽車動力轉向泵是用數控機床加工的,其噪聲值為71db ( a ) ,國內生產的汽車動力轉向泵是用靠模方法加工的,其噪聲值別為73db ( a )和75db ( a ) ,為了曲線對泵的噪聲的影響,本人用三坐標測量對定內表面進行精密測量,獲得定內表面的散點坐標,以matlab語言為工具對散點進行曲線擬合,觀察擬合效果,然後,用回歸方法求出了定過渡曲線的方程,並把該方程與理論方程標準型進行了比較,得出如下結論:用數控機床生產的汽車動力轉向泵的定過渡曲線方程非常接近理論5次曲線標準型,而用靠模方法加工的汽車動力轉向泵的定過渡曲線與理論5次曲線標準型相比較,則存在著較大的誤差,結合噪聲測試結果可知,定過渡曲線的優劣,對泵的噪聲大小有著重要的影響。
  15. Using the microwave selective heating property for materials, by setup equivalent equation, and first time inducing the electromagnetic field perturbation theory to the design of heating materials for substrate in mpcvd, three temperature distribution modes were established, including temperature distribution comprehensive mode of inhomogeneous plasma, temperature distribution composite mode of composite substrate materials, temperature distribution perturbation mode of composite materials, which ii provided an whole new technology route to the design of substrate heating system in mpcvd and guided the preparation of heating materials for substrate. and then the heating materials for substrate were designed and optimized to obtain large area homogeneous temperature distribution even larger than substrate holder ' s diameter. as an important part, this thesis researched the nucleation and growth of diamond films in mpcvd, systematically researched the effects of substrate pretreatment, methane concentration, deposition pressure and substrate temperature etc experimental technologic parameters on diamond films " quality on ( 100 ) single crystal silicon substrate in the process of mpcvd, characterized the films qualities in laser raman spectra ( raman ), x - ray diffraction ( xrd ), scanning electron microscopy ( sem ), infrared transmission spectra ( ir ), atomic force microscopy ( afm ), determined the optimum parameters for mpcvd high quality diamond in the mpcvd - 4 mode system

    該系統可通過沉積參數的精確控制,以控制沉積過程,減少金剛石膜生長過程中的缺陷,並採用光纖光譜檢測體的可見光光譜以監測微波等體化學氣相沉積過程;利用微波對材料的選擇加熱特性,通過構造等效方程,並首次將電磁場攝動理論引入到mpcvd的基片加熱材料的設計中,建立了非均勻等體溫度場綜合模型、復合介質基片材料的復合溫度場模型及復合介質材料溫度場攝動模型,為mpcvd的基片加熱系統設計提供了一條全新的技術路線以指導基片加熱材料的制備,並對基片加熱材料進行了設計和優選,以獲取大面積均勻的溫度場區,甚至獲得大於基片臺尺寸的均勻溫度區;作為研究重點之一,開展了微波等體化學氣相沉積金剛石的成核與生長研究,系統地研究了在( 100 )單晶硅基片上mpcvd沉積金剛石膜的實驗過程中,基片預處理、甲烷濃度、沉積氣壓、基體溫度等不同實驗工藝參數對金剛石薄膜質量的影響,別用raman光譜、 x射線衍射( xrd ) 、掃描電鏡( sem ) 、紅外透射光譜( ir ) 、原力顯微鏡( afm )對薄膜進行了表徵,確立了該系統上mpcvd金剛石膜的最佳的實驗工藝參數。
  16. The stability of nano - alumina aqueous dispersion is tokened by spectrophotometer and particle size distribution instrument. it is proved that when condition is dispersant pmaa = 0. 4 %, ph = 9, nano - - alumina content = 4 % ( wt % ), ultrasonic for twenty minites, excellent stable nano - alumina aqueous dispersion can be acquired. nano particle average size is 205nm

    光光度計和粒度表徵了納米粒散液的穩定性,結果表明納米相al2o3濃度為4 % ,散劑為陰聚電解質,用量0 . 4 % , ph = 9 ,採用超聲波散20鐘得到最好的散效果,納米顆粒的平均粒徑為205nm 。
  17. Mass analyzed ion kinetic energy spectrometer

    質量動能譜
  18. There are a few basic elements to a mass spectrometer : an inlet to introduce the sample gas into the vacuum of the mass spectrometer, an ion source to convert the sample gas molecules into positively charged ions, a mass filter to separate the ions using magnetic or electric fields and a detector that quantifies the amounts of ions at different masses

    質譜的幾個基本組成部:將樣品引入質譜的進樣系統,將氣體轉變為正源,使用磁場或電場的質量器,對不同質量數定量的檢測系統。
  19. The trace heavy metal determination instrument is a kind of instrument which combines the method of using ise and isfet microsensors based on a sensitive chalcogenide glass with the method of the stripping voltammetry to determinate the trace metals in seawater

    船載海水重金屬元素現場自動是一種聯合選擇性電極檢測技術和溶出伏安檢測技術自動檢測海水中痕量重金屬元素的器。
  20. Hydrogen flame ionization detector

    氫火焰
分享友人