電流比較式 的英文怎麼說
中文拼音 [diànliúbǐjiàoshì]
電流比較式
英文
current comparison system- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 流 : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
- 比 : Ⅰ動詞1 (比較; 較量高下、 長短、距離、好壞等) compare; compete; contrast; match; emulate 2 (比...
- 較 : Ⅰ動詞1 (比較) compare 2 [書面語] (計較) dispute Ⅱ副詞(比較) comparatively; relatively; fair...
- 式 : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
- 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
- 比較 : 1 (對比) compare; compare with; contrast; parallel (with); comparison; by comparison; in comp...
-
A large member of experimental findings was analyzed. the output torque of rera and plate er actuator were compared. the results showed that the torque transferred by ripple actuator is larger decuple than that of plate actuator
本文通過對大量的實驗數據進行分析,對波紋式與平盤式電流變傳動機構的輸出力矩進行比較,得出波紋式要比平盤式所傳遞的力矩大十倍的結論。Contraposing the measurement principle of the traditional hotwire air mass flowmeter, the reason of the excursion of the result for flow measurement was analyzed and inferred when environment temperature changed ; the method for temperature compensation and the realization circuit was given ; and compared the theory output of the new type hotwire air mass flowmeter with its real output after temperature compensation
摘要針對傳統型熱線式空氣質量流量計的測量原理,分析和推導出當環境溫度變化時對流量測量結果產生偏移的原因;提出了一種環境溫度的補償方法和具體的實現電路;並對經環境溫度補償后的一種新型熱線式空氣質量流量計的理論輸出和實際輸出進行了計算與比較。Compared with existing modulating method, torque ripple is greatly reduced by uniform modulating in one monocycle, increasing current slope of upcoming conducting phase instantaneously suppresses the torque ripple by 30 ’ during low speed with obviously lower initiating noise
採用單周期內各功率管均衡調制的方式,不僅消除了反向電流,而且與其他調制方式相比,可使轉矩脈動較小。At the end of the formation, both current and potential distributions are uniform. however, their distributions on the negative plate with the expanded grid design are a little more uniform
化成結束時電流密度和電位分佈都比較均勻,且拉網式負極板比輻射式負極板更均勻。Firstly. operation principle of induction heating is introduced and the actuality of the power supply for induction heating is summarized. then, the scheme of structure of the power supply is established : uncontrolled rectifier and buck chopper constitute dc circuit. in this part, operation principle of a kind of soft switching buck chopper is presented mainly and the conclusion that the power semiconductor devices operate in soft switching is also illustrated by analysing the operation principle of all stages ; series resonant inverter is selected as inverter circuit via comparing the advantage and shortcoming of parallel resonant and series resonant. moreover. the work principle of series resonant inverter is analysed and the calculating method of the best dead time is put forward as well
文中首先介紹了感應加熱電源的工作原理並綜述了國內外的研究現狀。接下來分析並制定了電源主電路的構成方案:在對比幾種功率調節方式的基礎上選擇了不控整流加斬波調壓作為直流部分。在這部分里,重點研究了一種軟開關buck變換器,通過分析各階段的工作原理說明了開關器件如何工作在軟開關狀態;對于逆變器部分,在比較了串、並聯逆變器優缺點的基礎上選擇了串聯諧振逆變器,並詳細分析了串聯逆變器的工作原理,提出了最佳死區的計算方法。Verification regulation of dc comparator bridge
直流比較儀式電橋檢定規程The effects of various additives elements and doping methods on foam nickel electrode ' s performance were studied using constant current charge - discharge test. we compared two doping methods : mechanical mixing doping and chemical co - precipitation doping
利用恆流充放電實驗等電化學測試方法研究了不同摻雜元素及摻雜方式對泡沫鎳電極的影響作用,對機械混合摻雜和化學共沉積摻雜進行了比較。Furthermore, this dissertation also gives a comprehensive analysis and comparison to the torque ripple factor, torque - current ratio and other aspects for pseudo - sinusoidal emf bldcm drived by 120 conduction mode, 180 conduction mode and self - synchronous svpwm mode respectively. the simulation and the experimental results indicate that self - synchronous svpwm method is more effective for minimizing the torque ripple without any expense of the torque - current ratio when the crest width of the back - emf waveform is less than 107 electrical angles
對準正弦波反電動勢無刷直流電動機在120導通方式、 180導通方式和自同步svpwm三種控制方式下的轉矩脈動系數、轉矩電流比等方面進行了全面的分析與比較,模擬研究和實驗結果表明,當反電動勢的平頂寬度小於107電角時,採用自同步svpwm控制方法可以在不損失轉矩電流比的基礎上,更有效地抑制電磁轉矩脈動。We obtained ptat and ctat current generator with low power consumption and high psrr, which in a simple circuit structure
用較簡單的電路形式實現了低功耗和高電源抑制比的ptat電流產生電路和ctat電流產生電路。The paper proceeds from the transient equation for voltage and torque, analyze the electromechanic time constant of permanent - magnet dc servomotors based on the theory, and compare with the several testing methods which are used normal in the engineering, point out the difference and applying area also for the testing error which is led to possibly
摘要為了準確評價伺服電動機的動態性能指標,從電機的電壓、轉矩平衡方程式出發,在理論上對永磁直流伺服電動機的時間常數進行了分析探討,並對工程實際中常用的幾種測試方法進行分析和比較,指出其差別和適用范圍以及可能造成的測試誤差。The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,
基於基爾霍夫定律的電流差動保護無論對於何種形式的輸電線路都是一種簡單、可靠、選擇性強的保護形式,電力系統的發展使得電流差動保護應用於線路保護成為需要,而電子、通信技術的發展使得電流差動保護應用於輸電線路成為可能。首先,本文對目前線路保護的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量電流差動保護易受正常負荷電流和故障過渡電阻影響的缺點,同時為加快差動保護的動作速度,對基於故障分量瞬時采樣值電流差動保護的原理、判據、動作特性等作了討論和分析,結果表明基於故障分量瞬時采樣值電流差動保護在可靠性、靈敏度、抗電流互感器飽和方面明顯優于常規相量電流差動保護,對電流差動保護各端的同步采樣方法和數據通信也進行了分析和評價。Compare to the traditional current methods, this method is not only immune from neutral grounding modes, but also more bearable to interference
該方法與單獨採用電流的電流型方法相比,可靠性更高,且不受系統接地方式的影響,能適用於較復雜的網路結構。The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。In this paper, several scheme of vscf is compared firstly, of which gets doubly - fed generating mode. doubly - fed vscf wind power generating system uses a doubly - fed induction generator, which rotate speed can be able to change with wind turbine, and it ensures a constant - frequency output, by controlling the frequency of current input into rotor windings. in vector trans control system, the control of stator active power and the control of stator reactive power can be essentially decoupled, and the former is via torque component and the latter is via exciting component of stator current
本文首先比較了幾種變速恆頻方案,從中選擇了雙饋式變速恆頻方案;它運用雙饋電機的工作原理,允許發電機轉速變化,而在電機轉子側接入低頻勵磁電流,通過控制該電流的頻率,保證雙饋電機定子輸出的頻率恆定;再結合矢量控制技術,通過調節轉子電流來控制定子電流的轉矩分量和勵磁分量,相應獨立地控制發電機輸出的有功功率和無功功率。This paper researches the non - direct - grounded system fault detection from software arithmetic view, whose main content is as follows : the paper analyses the system running characters before and after fault. and the paper analyses the fault transient signal and fault steady signal and all parts in fault steady signal after the single line - to - earth fault occurs, and discovers the fault laws and appearance of fault signal. the analyzing of the fault laws and fault phenomenon of non - direct - grounded system all above is the base of analyzing arithmetic
本文針對小電流接地系統選線的問題,從軟體演算法的角度進行了研究,主要內容如下:對小電流接地系統故障前和故障后系統的運行特點進行了分析,並且對小電流接地系統發生單相接地故障后,故障暫態信號、故障穩態信號以及故障穩態信號的各種成分進行了深入的分析,找到了故障的規律以及其故障信號的表現形式,為對各種演算法的分析比較打下了基礎。Under windows nt and labview development environment, using the linear fit module, exponential fit module > general polynomial fit module of labview to design a method for fitting the experiment data, the results of curve fitting indicate that the purpose of general polynomial fitting is better than the rest. separating the equivalent input impedance of magnetostrictive transducers without stimulate current from input impedance of it with stimulate loop based on the results of curve fitting, and determining the syntony frequency and electric simulation network parameters of magnetostrictive transducers by this input impedance. finally, with labview network functions, realizing magnetostrictive transducer electric simulation system based on web server and discussing a scheme for this system network by datasocket. the method of this paper can more accurately determine the syntony frequency and electric simulation network parameters of magnetostrictive transducers than the testing method of syntony & anti - syntony. at the same time, discussing virtual instrument measurement system and how to realize magnetostrictive transducer electric simulation network system by labview network functions of network virtual instrument measurement development environment
在windowsnt系統環境和labview虛擬儀器技術開發平臺下,首次利用labview中的直線擬合模塊、指數擬合模塊以及多項式擬合模塊,設計了一種對實驗所得數據進行曲線擬合的方法,對三種擬合方法進行了比較,曲線擬合結果表明,多項式擬合方法相對于其它兩種擬合方法效果更好;根據曲線擬合的結果可從帶激勵線圈的磁致伸縮換能器的輸入阻抗中分離出磁致伸縮換能器鐵芯在無激勵電流時機械振動形成的等效輸入阻抗,並由此輸入阻抗確定了磁致伸縮換能器的諧振頻率及其電氣模擬網路參數;最後通過labview提供的網路功能,實現了基於web服務器的磁致伸縮換能器電氣模擬虛擬儀器測試系統,並探討了通過datasocket技術實現該系統網路化的方案。This paper analyzes detailedly the principles on distributed busbar protection - current instantaneous value differential method, impedance method, and put forward the new method of current fault component phase method, then compares with these methods
本文詳細分析了分散式母線保護中的原理?瞬時值電流差動法、阻抗法,提出了電流故障分量相位法的新方法,將這幾種方法進行比較。Even if the fault spread from external fault zone to internal fault zone, the differential protection can avoid misoperation. main criterion of protection is composite - percentage current differential algorithm according to every sampled value, which can accelerate the protection ' s trip, reduce large amounts of calculation and have strong stability to ta saturation
本文採用基於采樣值的比率制動式電流差動保護演算法作為保護的主判據,可以明顯提高保護動作速度和減少計算量;具有較強的抗ta飽和能力,在區內故障時無制動,區外故障時有極強的制動特性。Different power circuits and control strategy of the single phase inverter in parallel condition are first analyzed, and half - bridge inverter is selected as the power circuit and current hysteresis control is selected as the control strategy
本文首先對單相逆變器的主電路結構和控制電路的結構在並聯條件下進行了比較分析,最後選用了半橋結構的主電路和內環為滯環控制的瞬時電壓電流雙閉環反饋控制方式。For the current source supply, the current waveforms are much easy to control though it has more complicated main circuit and more voltage harmonics
電流源方式主迴路比較復雜(需要將電壓源轉換為電流源) ,但電機電流波形容易控制, emi問題容易解決。分享友人