  1. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv網接地故障的形式、消弧圈接地的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以為主的城區10kv網中性點接地方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際來建立值計算模型,在考慮了網接地流變化、中性點阻取值大小、接地點接地阻值變化等多種影響因素的情況下,對中性點經消弧圈接地和經小阻接地方式下網的過壓水平和接地點短流大小進行了值計算,其計算結果與科院所作現場試驗進行了比較。
  2. Divider, coaxial line, trigger, signal processing, data acquisition, acquisition control and waveform analysis software is included in the device. when the device operate in the system, overvoltage is transferred to coaxial line by the divider. if the overvoltage amplitude is higher than initialization value, data acqusition card start sampling. when sampling is over, computer save data to file. engineer can analyse parameter of waveform by appropriative software reading data from file

    當裝置在運行時,系統中出現的過壓信號通過分壓器傳遞到同軸,通過觸發判斷,如果大於預先設定的值則啟動採集卡的同時采樣,采樣結束后,計算機把據存盤並以文件格式保存,管理人員隨時通過調用專用軟體調取文件進行各種分析。
  3. Overvoltage amplitude is higher than initialization value, data acqusition card start sampling. when sampling is over, computer save data to file. engineer can analyse parameter of waveform by appropriative software reading data from file. in the trial measurement, the device shows good performance. simulant trial and actual result indicate that method in the paper acquire approving effect, and the device can be used in the lokv distribution network

    當裝置在運行時,系統中出現的過壓信號通過分壓器傳遞到同軸,通過觸發判斷,如果大於預先設定的值則啟動採集卡的同時采樣,采樣結束后,計算機把據存盤並以文件格式保存,管理人員隨時通過調用專用軟體調取文件進行各種分析。
  4. The core of epiipc is the 51 series microcontrollers, which automatic detect the error signal of the circuit, like short circuit, overload, high voltage, low voltage, current leakage etc. meanwhile it monitors and tests the insulation level of high voltage cable, with convenience two variable key setting and full chinese version lcd display features

    本次研製的保護器以高檔51系列單片機為核心,能自動判斷中出現的短、過載、過壓、欠壓、漏等故障,並對高壓的絕緣水平進行實時監測,有方便的兩鍵設定和全中文液晶顯示功能。
  5. The last proposed method is based on the distributed parameter model, the algorithm utilizes searching and iteration methods to locate the fault point

    第三種方法採用的分佈模型,根據功率平衡原理推導出故障測距方程,並通過搜索迭代方法解之。
  6. Based on the above analysis results, the system design is finished. the system design principal is detailed. the system architecture and data transmission proctocal are discussed. in order to transmit multi - channel data simutaneously on the monacable, tdm ( time division multiplexing ) technique is adoped in the system design. a special code is designed for data transmission on the tool - bus, so that the too - bus can both supply power and transmit data

    包括單芯據傳輸系統的設計思想、結構設計和據傳輸協議的制定。在單芯據傳輸系統設計中,採用時分多復用技術,實現多種儀器據的同時傳輸。在儀器總上採用特殊的碼進行據傳輸,使得儀器總既能供又能傳輸據。