風負荷計算 的英文怎麼說
中文拼音 [fēngfùhéjìsuàn]
風負荷計算
英文
wind load calcutation- 風 : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
- 負 : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
- 荷 : 荷名詞(蓮) lotus
- 計 : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
- 算 : Ⅰ動詞1 (計算數目) calculate; reckon; compute; figure 2 (計算進去) include; count 3 (謀劃;計...
- 負荷 : [電學] load; charge; weight
- 計算 : 1 (求得未知數) count; compute; calculate; reckon; enumerate 2 (考慮; 籌劃) consideration; pla...
-
Then the air distribution system of the above - mentioned hotel ' s multi - function - hall was simulated with fidap, and the indoor temperature and velocity under the preliminary option was calculated. under the half - load condition of small air - supply quantity and slow velocity, finds that the problem has arisen, which the cold jets fall too fast in summer and the air distributes layer upon layer in winter
然後應用fidap對上述旅館的多功能廳空調氣流組織初步方案進行了數值模擬計算,預測了該初步方案的室內溫度、速度分佈,發現在送風量和送風速度小的半負荷工況下,會出現夏季送風時冷射流過早下降,冬季送風時氣流分層分佈的現象。Building site equipment - building site stairways intended for access and evacuation of personel - materials - dimensions - calculation loads - resistance and safety requirement - tests
建築工地設備.建築工地專用排風機及輔助設備用樓梯.材料.尺寸.負荷計算.耐用性和安全要求.試驗The most effective way to do so is to analyze the special indoor environment of swimming pools, calculate the proper volume of moisture migration and ventilation, and check carefully the heating / cooling loads. good air currents organization could also be essentially necessary
指出要解決好游泳池內表面防結露問題,首先需要從設計出發,分析游泳池的室內特殊環境,計算游泳池散濕量、通風量、冷熱負荷,合理進行氣流組織設計。Firstly, system cooling load, ventilation flux and thermal and humid processing were calculated and its feasibility was showed from the temperature, humidity of indoor air and fresh air flux
首先進行了系統的負荷、通風量及熱濕處理計算,從室內空氣溫度、濕度和新風量三個方面說明其可行性。In the deregulated power market , the power grid operator is facing many uncertainty and risks risk concept , risk analysis approach and risk management are introduced in chapter ii , the maj or risks of grid operators is analyzed and evaluated in details based on the real situation and data of yueyang city, hunan province , the economic risk resulting from the uncertainty of load prediction of whole system , generation capacity and parallel quantity of the large enterprises self - owned power plant are analyzed meanwhile , the increase of large enterprises self - owned power plant may cause economic and security risks considering different risk , the qualitmive and quantitative approaches are respectively adopted the direct and indirect congestion risks are evaluated based on probabilistic theory and decision theory the retail pricing and trade modes are major areas embracing risks as well chapter iii divides the risks in internal and external ones based on the characteristics of risk and put forward the layered risk management approach
詳細分析和論述了電網經營企業面臨的各種風險。基於湖南省岳陽地區電力市場的實際情況和多年歷史數據,採用定性分析和定量計算的手段具體分析了負荷、自備電廠發電量和上網電量預測不確定性以及自備電廠的大量增加給電網企業帶來的經濟性風險和安全性風險。無論是長期還是短期,阻塞不僅會對電網造成直接風險,還可能造成間接風險。Analyses the determination of surface heat transfer coefficient, interior building envelope load, air infiltration load, equipment load and heat storage load, etc
摘要分析了民用建築舒適性空調負荷計算中表面傳熱系數、內圍護結構負荷、滲透風負荷、設備負荷、蓄熱負荷的確定等問題。It is indicated that hrv has many advantages certified by theoretic analyze and engineering practices, such as fully ventilating, abundant fresh air supplying, energy saving, etc. comparing with independent fresh air supplying, hrv is supposed to cause potential problems, - in summer load of fan - coil units will be increased, and the wet operating mode will be aggravated, the indoor relative humidity will be increased
新風換氣機供應新風是住宅空調系統較為理想的新風供應方式,本文通過理論計算及工程實踐表明採用,新風換氣機具有換氣充分、新風量保證、節能等優點。但與新風機組獨立供應新風相比,新風換氣機供應空調系統新風時,會造成夏季風機盤管負荷增加,濕工況加重,室內相對濕度有增加趨勢。Based on a room model with constant air volume system, calculate its hourly load in a whole year, and then determine the different state points of air supply
建立了一個定風量系統的房間模型,計算其全年逐時負荷,從而確定送風狀態點的全年變化趨勢。Return air duct system should not be applied to public kitchen ventilating. 2
最後根據有關文獻列出了廚房空調負荷、通風計算方法。This software are compiled in vc + + computer language. the main function of the application is to calculate the load limitation of an air - cooling steam turbine - generator set under distinct flux of cooling water, environmental temperature and environmental wind speed, and the back pressure safeguard curve of the target steam turbine are considered
應用軟體以vc + +為開發平臺,考慮了特定汽輪機組的背壓保護曲線,通過計算空冷系統的熱力特性,實時給出當前環境溫度和環境風速以及循環水流量下機組的上限負荷,從而指導機組的運行。To the exploration, the author studies sailimu and buerjin wind - electricity field. the study shows the short circuit proportion supplied by wind - electricity is very high, so the wind - generator can " t be treated as a simple equipment that assumes energy, nor a simultaneous generator, if as an unsimultaneous generator, the short circuit will be different when the capacity changes, as a sequence, the relay will be influence too
以上研究結果表明:風力發電機提供的短路電流在短路電流中占相當大的比例,因此不能將風力發電機作為簡單負荷處理,也不能視為同步機處理,即使作為異步機處理,當採用容量不同時,短路電流大小也有變化,因此,也就直接影響繼電保護的整定計算。And also this paper analyzes many important aspects about the design of the variable air volume system, for exam pie the calculation method of cold and volume, the choice of tuyeres, the adjustment operating mode of the fan during summer and winter and proffer form some opinions
對系統設計中各主要方面諸如負荷計算、風量取值、風口選型以及系統在冬夏運行調節時的風機控制方式,系統運行模式作了一定的探討並提出了自己的見解。Presents the characteristics of recreational natatoria, discusses the modes of hvac systems, heat and moisture load calculation, ventilation rate determination and winter ventilation operation adjustment, and provides two calculation methods of outdoor humidity ratio in transition seasons
摘要介紹了娛樂性游泳館的特點,探討了暖通空調系統形式、熱濕負荷計算、通風量確定、冬季通風運行調節等問題,提出了兩種過渡季室外含濕量計算方法。分享友人