arcing fault 中文意思是什麼

arcing fault 解釋
閃故障
  • arcing : 產生電弧
  • fault : n 1 過失,過錯;罪過,責任。2 缺點,缺陷,瑕疵。3 (獵狗的)失去嗅跡。4 【電學】故障,誤差;漏電...
  1. Combination fuse - switch ( cfs ) unit compartments shall be designed and type - tested for arcing fault containment where the energy level available to the input terminals of the compartment exceeds 1, 000, 000 a2 seconds

    試譯:間隔式組合熔絲開關櫃( cfs )的隔室設計應滿足,在隔室的輸入端子的有效能級超過100萬安培秒之處,能進行閃故障包容以及閃故障包容的型式試驗。
  2. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  3. Enclosed low - voltage switchgear and controlgear assemblies - part 1 : typetested and partially typetested assemblies ; technical report : guide for testing under conditions of arcing due to an internal fault iec 61641 : 1996

    封閉式低壓開關和控制裝置.第1部分:型式試驗和部分型
  4. From the results of simulation, it is found that the fault circuit selecting method proposed in this thesis is applicable to arcing grounded

    最後,本文利用簡單的電弧模型討論了電弧接地方式對于本文演算法的影響。經算例模擬,本文的演算法可以適應電弧接地方式。
  5. Then, the fault circuit selecting method utilizing wavelets transform is proposed to obtain useful fault transient components. the results of simulation denote that the methods in this paper are efficient and reliable. lastly, the influences of arcing grounded are discussed

    然後再利用小波變換的時頻局部性提取故障信號中的暫態分量進行選線分析,經理論分析和算例模擬,可以發現本文提出的方法是有效、可靠的。