calibration section 中文意思是什麼

calibration section 解釋
定型段
  • calibration : n. 1. 測定口徑。2. 刻度,標度,劃度數。3. 校準;標準化。
  • section : n 1 (外科、解剖的)切斷;切割;切開。2 【外科】切片,【金相】磨石。3 (果子的)瓣。4 【數學】截...
  1. The dissertation is mainly including four section : the first is the experiments done in the tank, which will supply the reliable information of imaging data ; the second is image edge detection by the use of the art of the zernkie moments, which is used to detect the liner and threaded edge of the object, the third is the underwater camera calibration technique, the forth is automatic positioning the location of the camera by used of the art of cross - ratio, the result of which is satisfied

    本文工作分為四個部分:第一部分是水槽實驗部分,它為后續的工作提供了可靠的圖像數據信息;第二部分是基於zom距的直線、曲線邊緣提取技術及相關的與處理技術;第三部分,水下攝像機標定技術研究,基於改進的tsai演算法,採用逐步分解的標定策略。並探討了一種相對簡單的、靈活的標定技術;第四部分是攝像機定位技術研究,採用具有平移不變性的交比進行攝像機定位,模擬試驗的最大誤差不超過2 ,效果還是令人滿意的。
  2. Using the system designed in this thesis work, flow field calibration of the wind tunnel is accomplished, which covers dynamic pressure drop coefficient, dynamic pressure time stability, axial static pressure gradient, boundary layer, and degree of turbulence, etc. boundary layer measuring principle and method are especially described in detail, the relationship between boundary layer thickness, wind speed setting, and the depth of the experimental section is summarized, and finally the calibration data for th e model center zone under specific wind speed are given

    然後利用本文設計的系統完成了落差系數、動壓時間穩定姓、軸向靜壓梯度、邊界層及湍流度等內容的流場校測。特別對邊界層測量的原理及方法做了較詳盡的敘述,總結出邊界層厚度與設定風速、實驗段深度的關系,然後給出模型中心區一定風速下校正數值。
  3. In this thesis, the calibration, laying and measuring error of the concentric capacitance fuel sensor are researched. and the major work is following : 1. taking the fuel entity of fully - filled airplane oil tank as studying object, the outhor calculates the central points of the section contours and the volume of the remnant fuel under the section height by means of numerical calculation

    本文研究了同心電容式油量傳感器的標定、敷設和誤差分析的方法,主要工作如下: ( 1 )以飛機油箱滿載狀態下的油液實體為研究對象,用數值方法計算出實體模型各剖面的面積中心點和各剖面高度下的油液體積值。
  4. Section 2 begin to introduce the measuring methodology, a new clock calibration algorithm is introduced as well. in section iii, various network topologies and scenarios are described ; results and analyses are also given

    第三章首先給出測試網路的拓撲結構和網路環境,用實際測試結果驗證測量方法的正確性,然後對無線移動網路中實時語音業務的傳輸性能進行測試、分析和評估。
  5. As scl does not have a shipping section, it will be necessary for the overseas client to arrange for the delivery of equipment to scl and for collection after calibration. it is recommended that the client appoint a transportation agent who can make all the necessary arrangements for customs clearance, insurance, packing and transportation

    由於標準及校正實驗所並無貨運部門,因此海外客戶必須自行將儀器送交本所,並須于校正完成後自行領回有關儀器,客戶最好能委託運輸代理替其安排一切所需的清關、保險、代包裝及運送事宜。
  6. Experimental results on butane and butane - plant oil flames indicated that, measurement precision by the multi - wavelength method is strengthened by taking radiation information on multiple wavelength units into consideration, and moreover, the radiation calibration procedure is simplified, in that a halogen light source is used instead of in situ flame radiation. in section 2, fluctuation and averaging analyses are carried out on optical transmission signals by particles passed through laser beams to derive particle size and concentration in measuring area, furthermore, correlation calculations are conducted on two adjacent laser beam signals to obtain flowing velocity of particle

    對丁烷氣體火焰及丁烷-植物油混合燃料火焰的測量結果表明,多波長分析方法優于傳統的雙色法,表現在兩個方面:一、由於綜合考慮多個波長單元上的火焰輻射信息,多波長方法的測量精度比雙色法有較大的提高;二、在多波長分析方法中,採用標準鹵素燈進行相對輻射強度標定,簡化了雙色法中的火焰絕對輻射強度的標定。
  7. Calibration specification for light section microscopes

    光切顯微鏡校準規范
  8. In the third section, the simulation on music direction finding and the influence that is caused by snr, space between antennae, signal frequency and channel mismatch is analyzed. according to the single known - direction source calibration method, the channel mismatch is calibrated

    第三部分介紹了music測向基本原理,詳細分析了信噪比、陣元間距、通道失配等因素對其測向結果的影響,並利用單信號有源校正方法,對通道失配進行了校正,提高了測向精度。
  9. Responsible for management, maintenance, calibration and repair of existing equipments in microbiological section

    負責管理,維護,校正和維修在微生物檢驗方面的現有設備。
分享友人