carrier sensitivity 中文意思是什麼

carrier sensitivity 解釋
載波靈敏度
  • carrier : n 1 運送人,搬夫;負荷者;使役,〈美國〉信差,郵遞員;送報人;〈英國〉運輸行,運輸業者。2 傳書鴿...
  • sensitivity : n. 1. 敏感(性);感受性。2. (儀器等的)靈敏性。3. 【攝影】感光度。
  1. After study on the technology of probe head of the optical fiber, a biosensor for determination of cholesterol which based on fluorescence quenching and adopted phase shift & phase lock technique to detect the change of light intensity was developed, in this biosensor, the cellulose acetate cod enzyme membrane was took as sensitivity basic dollar, ru ( phen ) 32 + was took as indicator of oxygen and furcated optical fiber as conduct carrier of light signal

    通過對光纖探頭組裝技術的研究,以醋酸纖維素cod酶膜為敏感基元,釕( ) -鄰菲咯啉為氧指示劑,分叉光纖為光信號傳導載體,採用相移法和鎖相放大技術設計了一種基於熒光猝滅原理的測定膽固醇用的生物傳感裝置。
  2. This compound was firstly used as a fluorescence carrier of chemical sensors to examine the toxic p - nitroaniline. compared with conventional methods, this sensor has lower cost, wider detection range, higher sensitivity and selectivity, better reproducibility and reversibility. 4

    與傳統的檢測對硝基苯胺的方法相比,該傳感器操作簡便,製作成本低廉,在較寬的范圍內有響應,具有較高的靈敏度和選擇性,重現性好,響應迅速。
  3. According to the principle of energy transfer, an opto - chemical sensor with higher sensitivity to detect picric acid by using the mixture of porphyrin dimer and anthracene as fluorescent carrier has been developed

    基於能量轉移原理,採用卟啉二聚體和蒽的混雜體系作為熒光載體研製了一種靈敏度更高的苦味酸光化學傳感器。
  4. 4. in data acquisition system, the application of phase - locked and synchronous detection reduce the cost of the whole system and improve the sensitivity. carrier signal and modulation signal achieve entirely synchronous too

    數據採集系統採用鎖相技術、同步檢波的原理,降低了整個系統的成本,提高了靈敏度,並使得載波信號與調制信號完全達到同步。
  5. The performance targets of acquisition and tracking : the code rate of pseudorandom signals is 1m - 5mhz, the code length is 255. 511, the receiving sensitivity is - 118dbm, the dynamic range is 70db. the doppler of carrier is 75khz, the time that 10 targets are captured within 0. 2s

    捕獲和跟蹤的性能指標:偽隨機信號碼率1m 5m比特/秒,碼長是255 、 511 ,接收靈敏度是- 118db ,信號動態范圍是70db載波普勒是75khz ,目標捕獲在0 . 2秒內。
  6. Except for types of stationary phase, components of mobile phase and types of detectors, other prescribed conditions under each type, such as internal radius and length of chromatographic column, brand of stationary phase, carrier granularity, flow speed of mobile phase, as well as proportion, column temperature, volume of incoming samples of different components of mixed mobile phase and sensitivity of detector can be appropriately changed to accommodate different chromatographic system and reach requirements for applicable test of the system

    各品種項下規定的條件除固定相種類、流動相組成、檢測器類型不得任意改變外,其餘如色譜柱內徑、長度、固定相牌號、載體粒度、流動相流速、混合流動相各組成的比例、柱溫、迸樣量、檢測器的靈敏度等,均可適當改變,以適應具體的色譜系統並達到系統適用性試驗的要求。
  7. It is proposed that the higher dose condition creates more hot carriers but the lower sensitivity to hot carrier effect. therefore, the optimum dose for reliability is determined from the trade - off between the above two aspects. finally, a simple model is proposed and discussed

    本文還深入研究了sde區摻雜濃度對器件熱載流子可靠性的影響,指出濃度的提高雖然會產生更多的熱載流子,但由於其對熱載流子損傷的敏感度降低,因此將存在一種折衷,最後通過一個簡單的寄生電阻模型,對摻雜濃度提高后,器件對熱載流子損傷敏感度降低的現象做出了很好的解釋。
  8. Finally, the mutual spreading between the sample zone and the carrier solution in flow injection analysis ( fia ), would always result in the sample zone ' s widening and reducing the sensitivity

    最後,流動注射分析中載流溶液與樣品的相互擴散會導致樣品區變寬而降低靈敏度。用空氣作載流就沒有擴散,靈敏度極高。
  9. After measuring dark current, photocurrent and response to x pulse of gaas detector before and after 1. 7 mev electronic radiation, the response tune, fall time of trailing edge, full width of half maximum ( fwhm ), sensitivity, carrier life, mobility are researched and contrasted. the result shows that the response speed of detector, time resolution ratio and nonlinear of back edge of output signal have been improved greatly after electronic radiation. though sensitivity of the detector reduces, its measuring range can be widened

    為了使探測器的性能得到進一步的提高,我們對其進行了電子輻照改性,並測量了本徵砷化鎵探測器和經過1 . 7mev電子輻照的探測器的暗電流、光電流及對x射線的脈沖響應,並對其響應時間,后沿下降時間,半高寬( fwhm ) ,載流子壽命,靈敏度進行對比,研究,結果顯示經電子輻照后的探測器的性能得到了改善,使響應速度,分辯率進一步提高,並消除了探測器輸出信號后沿的非線性,雖靈敏度有所降低,反而使其測量范圍得以拓寬。
  10. Fluorescein and porphyrin have been linked by an alkyl chain, and been firstly used as a fluorescence carrier of opto - chemical sensors. based on the principle of energy transfer, it examined the iodine in the aqueous solution with high sensitivity and wide detection range

    通過脂肪鏈把熒光素和卟啉連接起來,並首次把它作為熒光載體應用於光化學傳感器的研製,基於分子內能量轉移原理檢測了水溶液中的單質碘,該傳感器靈敏度高,檢測范圍寬。
  11. The impact of makeup gas for packed column on sensitivity of fid ( flame ionization detector ) was studied with different concentration sample and different carrier gas flow in order to find out optimal sensitivity of gas chromatogram

    摘要本文研究氣相色譜填充柱在不同柱流量和不同濃度的苯系物樣品,使用尾吹氣對fid檢測器靈敏度的影響,以確定分析儀器的最佳靈敏度。
  12. Finally, the mutual spreading between the sample zone and the carrier solution in flow injection analysis ( fia ) would always result in the sample zone ' s widening and reducing the sensitivity ( obviously, the case in which the carrier solution was the reaction reagents was not included )

    該傳感器晶元保存於冰箱( 4oc ) 10天後無明顯變化,且能連續重復使用200次而無明顯變化(測定值rsd小於5 ) ,該傳感器晶元成功用於血清中尿酸含量的測定,結果令人滿意。
  13. The solution background that resulted from the chemical interference, would be the primary factor that effected the sensitivity. especially in the present microfluidic system, the chemical background which was usually inevitable because of the carrier solution, would be eliminated by means of using air as the carrier flow, thus a great signal noise ratio ( snr ) and a great sensitivity could be obtained

    在微量分析和超微量分析里,化學干擾產生的溶液背景是影響靈敏度的主要因素,尤其在微流控系統中,載流溶液的背景不可避免,用空氣作載流就可以消除背景而獲得高信噪比和高靈敏度。
  14. Study of sensitivity and stability of methane carrier catalytic element

    甲烷載體催化元件靈敏度穩定性的研究
分享友人